Product Data Sheet
4314/17T
INDEX
1
2
General ...................................................................................................................................................................... 2
Mechanics ................................................................................................................................................................. 2
2.1
2.2
3
3.1
3.2
3.3
3.4
3.5
3.6
4
4.1
4.2
5
5.1
5.2
6
6.1
General ................................................................................................................................................................ 2
Connections ........................................................................................................................................................ 2
Operating Data - Electrical Interface - Input ........................................................................................................ 3
Electrical Operating Data .................................................................................................................................... 4
Operating Data - Electrical Interface -Output ...................................................................................................... 4
Electrical Features............................................................................................................................................... 5
Aerodynamic ....................................................................................................................................................... 7
Sound Data ......................................................................................................................................................... 7
General ................................................................................................................................................................ 7
Climatic requirements*) ....................................................................................................................................... 7
Electrical Safety................................................................................................................................................... 7
Approval Tests .................................................................................................................................................... 8
General ................................................................................................................................................................ 8
Operating Data .......................................................................................................................................................... 2
Environment .............................................................................................................................................................. 7
Safety ......................................................................................................................................................................... 7
Reliability ................................................................................................................................................................... 8
page 1 of 8
Product Data Sheet
1
General
Fan
clockwise
Air outlet over struts
Ball bearing
any
Fan type
Rotational direction looking at rotor
Airflow direction
Bearing system
Mounting position
2
Mechanics
2.1
General
Width
Height
Depth
Weight
Housing material
Impeller material
Max. torque when mounted across both mounting
flanges
Screw size
119,0 mm
119,0 mm
32,0 mm
0,220 kg
Plastic
Plastic
wire outlet corner: 20 Ncm
remaining corners: 20 Ncm
ISO 4762 - M4 degreased, without an additional
brace and without washer
2.2
Connections
Wires
310 mm
+- 10,0 mm
24
1,55 mm
Electrical connection
Length of lead wire
Tolerance
Wire gauge (AWG)
Insulation diameter
Wire 1
Wire 2
Wire 3
Wire 4
Colour
red
blue
violet
white
Operation
+ UB
- GND
NTC:
Alarm
The auxilliaries shown on the schematic diagram (which are required for the intended use) are not part of our delivery.
3
Operating Data
page 2 of 8
Product Data Sheet
3.2
Electrical Operating Data
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal;warm-up
time before measuring 5 minutes (unless otherwise specified).In the intake and outlet area
should not be any solid obstruction within 0,5 m.
Measurement
conditions:
∆p
= 0: corresp. to free air flow (see section 3.5)
I:
corresp. to arithm. mean current value
Name
TU 0001
NTC 0001
Features
Voltage range
Nominal voltage
Power consumption
Tolerance
Current consumption
Tolerance
Speed
Tolerance
Starting current
consumption
Name
TU 0002
NTC 0002
Features
Voltage range
Nominal voltage
Power consumption
Tolerance
Current consumption
Tolerance
Speed
Tolerance
Condition
TU: <= 30 °C
NTC: >= 78 kOhm
Condition
∆p
= 0
∆p
= 0
∆p
= 0
TU / NTC:
0002
∆p
= 0
TU / NTC:
0002
∆p
= 0
TU / NTC:
0002
Symbol
U
U
N
P
Values
18,0 V
1,2 W
+- 25,0 %
66 mA
+- 25,0 %
1.400 1/min
**)
24,0 V
1,6 W
+- 25,0 %
68 mA
+- 25,0 %
1.400 1/min
**)
32,0 V
2,2 W
+- 25,0 %
68 mA
+- 25,0 %
1.400 1/min
**)
Condition
TU: >= 50 °C
NTC: <= 34 kOhm
Condition
∆p
= 0
∆p
= 0
∆p
= 0
TU / NTC:
0001
∆p
= 0
TU / NTC:
0001
∆p
= 0
TU / NTC:
0001
Symbol
U
U
N
P
Values
18,0 V
2,9 W
+- 25,0 %
160 mA
+- 25,0 %
2.250 1/min
+- 12,5 %
24,0 V
4,8 W
+- 25,0 %
200 mA
+- 25,0 %
2.800 1/min
+- 9,0 %
32,0 V
5,8 W
+- 25,0 %
180 mA
+- 25,0 %
2.800 1/min
+- 9,0 %
I
n
780 mA
I
n
**)
Vario Pro:
Unless otherwise specified in the table a general fan speed tolerance applies, relating to the
maximum value of the required characteristic curve. Tolerance:+- 9,0 %
3.3
Operating Data - Electrical Interface -Output
page 4 of 8
Product Data Sheet
Tacho type
Alarm type
None
/17 (high = ok, Open collector)
Features
Alarm operating voltage (UBA)
Alarm signal Low *)
Alarm signal High *)
Maximum sink current
External resistor
Alarm start-up delay time (t2)
Alarm trip speed limit (nG)
Tolerance
Alarm at sense failure
Alarm latch
Alarm isolated from motor
Note
I sink: 2 mA
I source: 0 mA
External resistor Ra from
UBA to UA required. All
voltage measured to GND.
Values
<= 60 V
<= 0,4 V
60 V
<= 20 mA
<= 15 s
1.150 1/min
+- 100 1/min
Yes
No
No
3.4
Electrical Features
page 5 of 8