Wire Wound Magnetically Shielded SMD Power Inductor (High Current)
ASPI-2010HC
FEATURES:
• Iron based core provides large saturation current
• Low DCR lowers power loss
• Magnetic-resin shielding reduces leakage flux and
Electro Magnetic Interference (EMI)
• Metal core designed for excellent shock resistance
• Low profile package takes up little PCB space
Pb
RoHS/RoHS II Compliant
2.0 x 1.6 x 1.0 mm
APPLICATIONS:
• Smart Phone, Tablet, Notebook, Desktop, Server
• Blu-Ray Disc Recorder, Set Top Box
• Portable Gaming Device, Navigation Device
ELECTRICAL SPECIFICATIONS:
Abracon P/N:
Operating Temperature & Humidity
:
Storage Temperature & Humidity:
Part Number
ASPI-2010HC-
Inductance Code
Units
Symbol
ASPI-2010HC-R24
ASPI-2010HC-R47
ASPI-2010HC-R68
ASPI-2010HC-1R0
ASPI-2010HC-2R2
ASPI-2010HC-100
Inductance
μH
L
0.24
0.47
0.68
1.0
2.2
10
ASPI-2010HC
-40˚C ~ +125˚C (including self heating)
-10˚C ~ +40˚C and 70% R.H. max. (In tape and reel)
DC Resistance
Max
Ω
Max
0.040
0.049
0.065
0.090
0.170
0.826
Min. Self
Resonant
Frequency
MHz
SRF Min
145
102
77
70
39
15
5.50
4.70
4.00
3.85
2.15
0.95
Saturation
Current Typ
A Typ
Isat
4.50
4.00
3.50
3.35
1.90
0.80
3.45
3.10
2.80
2.35
1.70
0.75
Saturation
Current Max
A Max
Temperature
Rise Current
Typ
A Typ
Irms
3.00
2.70
2.50
2.05
1.45
0.65
Temperature
Rise Current
Max
A Max
Inductance
Tolerance
%
M
M
M
M
M
M
M
OPTIONS AND PART IDENTIFICATION
Test Conditions:
a. Ambient Temperature: 20± 15
o
C
b. Relative Humidity:
65%±20%
c. Air Pressure:
86KPa to 106KPa
Inductance (L): WK3260B
LCR
meter or equivalent, 1MHz, 1V.
Direct
Current Resistance (DCR): HIOKI 3540 or equivalent.
Saturation Current (Isat): WK3260B
LCR
meter or equivalent.
Temperature rise current (Irms):
Electric
Power, Electric current meter, Thermometer.
Saturation Current Max:
DC
current at which the inductance drops less than
30%
from its
value
without
current.
Saturation Current Typ:
DC
current at which the inductance drops approximate 30% from its
value
without
current.
Irms:
DC
current that causes the temperature rise (ΔT) from 20°C ambient.
ΔT<40°C
for Irms max;
ΔT
is approximate 40°C for Irms typ.
ASPI-2010HC-
-
Inductance Code
Please refer to the
table above
ABRACON IS
ISO9001:2008
CE RTIFIED
Tolerance
M: ±20%
T: Tape and Reel
(2kpcs / reel)
Packaging
Revised: 01.07.13
30332 E speranza, Rancho Santa Margarita, California 92688
tel 949-546-8000
|
fax 949-546-8001
| www.abracon.com
Visit www.abracon.com for Terms & Conditions of Sale
Wire Wound Magnetically Shielded SMD Power Inductor (High Current)
ASPI-2010HC
ELECTRICAL CHARACTERISTICS CURVES
Pb
RoHS/RoHS II Compliant
2.0 x 1.6 x 1.0 mm
OUTLINE DIMENSIONS:
Recommended Land Pattern
Δf: Clearance
between terminal and the surface of plate must be 0.1mm max when coil is placed on a flat plate.
A
2.0±0.2
B
1.6±0.2
C Max.
1.0
D
1.2±0.2
E
0.60±0.2
F
0.80±0.2
a Typ.
0.70
b Typ.
0.70
c Typ.
1.70
Dimensions: mm
Materials
No
1
2
3
4
5
Components
Core
Wire
Magnetic
Glue
Substrate
Top Electrodes
Material
Soft magnetic metal
Polyurethane system enameled copper
wire
Epoxy resin and magnetic powder
FeNiCu/Ag
Sn alloy
ABRACON IS
ISO9001:2008
CE RTIFIED
Revised: 01.07.13
30332 E speranza, Rancho Santa Margarita, California 92688
tel 949-546-8000
|
fax 949-546-8001
| www.abracon.com
Visit www.abracon.com for Terms & Conditions of Sale
Wire Wound Magnetically Shielded SMD Power Inductor (High Current)
ASPI-2010HC
REFLOW PROFILE:
Δ
Preheat condi
tion: 150
~200˚C
/60~120sec.
Δ
Allowed time above 217˚C: 60~90sec.
Δ
Max temp: 260˚C
Δ
Max time at max temp: 5sec.
Δ
Solder paste: Sn/3.0Ag/0.5Cu
Δ
Allowed Reflow time: 2x max
Pb
RoHS/RoHS II Compliant
2.0 x 1.6 x 1.0 mm
TAPE & REEL:
T: 2,000pcs / reel
Ao
1.90±0.05
Bo
2.20±0.05
W
8.0±0.1
E
1.75±0.1
F
3.5±0.05
Po
4.0±0.1
P
1
4.0±0.1
P
2
2.0±0.05
Do
1.5+0.1/-0.0
T
0.25±0.02
K
1.20±0.05
Storage Conditions
a.
b.
c.
d.
To maintain the solderability of terminal electrodes and to
keep
the packing material in good condition, temperature and
humidity in the storage area should be controlled.
Recommended conditions: -10
o
C
~ +40
o
C,
70%
RH (Max.)
Even
under
ideal storage conditions, solderability of products electrodes may decrease as time passes. For this reason, product
should be
used
within one
year
from the time of delivery.
Dimension: mm
In case of storage over 6 months, solderability shall be checked before actual
usage.
ATTENTION:
Abracon Corporation’s products are COTS – Commercial-Off-The-Shelf products;
suitable
for Commercial,
Industrial
and, where designated,
Automotive
Applications.
Abracon’s products are not specifically designed for Military, Aviation, Aerospace,
Life-dependant
Medical applications or any application requiring high reliability where component
failure
could
result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme operating
environment,
written consent and
authorization
from
Abracon Corporation is required. Please contact Abracon Corporation for more information.
ABRACON IS
ISO9001:2008
CE RTIFIED
Revised: 01.07.13
30332 E speranza, Rancho Santa Margarita, California 92688
tel 949-546-8000
|
fax 949-546-8001
| www.abracon.com
Visit www.abracon.com for Terms & Conditions of Sale