Bel Power Solutions MAP80 Series of power supplies provides
reliable, tightly-regulated DC power for commercial and industrial
systems which require high peak current capabilities. Wide-range AC
input and full international safety, EMI, and ESD compliance ensure
worldwide acceptance. All units bear the CE Mark.
The MAP80 utilizes a variable frequency design with a thermally
efficient U-channel chassis to provide full power operation in
convection-cooled applications. Design innovations include metric
and SAE mounting inserts on each mounting surface to provide
integration flexibility. Dual-mode connectors provide traditional
terminal block connections or popular single-row Molex connector
mating.
Single-output models feature wide-range output adjustability to meet
a wide variety of standard and user-specific output voltage
requirements.
RoHS Compliant
Wide Range Input for 110/220 VAC Applications
CE marked to Low Voltage Directive
Input Transient and ESD Compliance to EN61000-4-2/-3/-4
Meets EN55022, Class B Limits
TTL Compatible Power Fail Signal
Greater than 175,000 Hours MTBF
Metric and SAE Mounting Inserts
2
MAP80 Series
MODEL
7
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAX
OUTPUT
CURRENT
PEAK
OUTPUT
CURRENT
1
LINE
REGULATION
LOAD
REGULATION
RIPPLE
&
NOISE
2
INITIAL SETTING
ACCURACY
MAP80-1012G
6
MAP80-1024G
6
12V/15V
24V/28V
11.5V to 15.5V
23.0V to 29.0V
7.5/6.0A
3
3.8/3.2A
9.2/7.3A
4.6/3.9A
0.2%
0.1%
±1%
0.5%
1%
0.5%
11.76V to 12.15V
23.8V to 24.2V
MODEL
7
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
CURRENT
PEAK
OUTPUT
CURRENT
4
LINE
REGULATION
LOAD
REGULATION
RIPPLE
&
NOISE
2
INITIAL SETTING
ACCURACY
+5V
MAP80-4000G
5
+12V
-5V
-12V
+5V
MAP80-4001G
5
+24V
-12V
+12V
+5V
MAP80-4002G
5
+12V
-12V
+12V
+5V
MAP80-4003G
5
+15V
-5V
-15V
+5V
MAP80-4004G
5
+24V
-15V
+15V
+5V
MAP80-4010G
5
+12V
-5V
-12V
4.8V to 5.5V
11.52V to 12.48V
Fixed
Fixed
4.8V to 5.5V
23.04V to 24.96V
Fixed
Fixed
4.7V to 5.5V
11.52V to 12.48V
Fixed
Fixed
4.8V to 5.5V
14.4V to 15.6V
Fixed
Fixed
4.8V to 5.5V
23.04V to 24.96V
Fixed
Fixed
4.8V to 5.5V
11.52V to 12.48V
Fixed
Fixed
14A
4A
1A
1A
14A
2A
1A
1A
14A
4A
1A
1A
14A
3.5A
1A
1A
14A
2A
1A
1A
14A
4A
1A
3A
16A
7A
1A
1A
16A
3.5A
1A
1A
16A
7A
1A
1A
16A
6A
1A
1A
16A
3.5A
1A
1A
16A
7A
1A
3A
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
1%
1%
2%
2%
1%
1%
2%
2%
1%
1%
2%
2%
1%
1%
2%
2%
1%
1%
2%
2%
1%
1%
2%
2%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
5.1V to 5.2V
11.9V to 12.1V
-4.8V to -5.4V
-11.5V to -12.5V
5.1V to 5.2V
24.0V to 24.1V
-11.5V to -12.5V
11.5V to 12.5V
5.1V to 5.2V
12.0V to 12.1V
-11.6V to -12.4V
11.6V to 12.4V
5.1V to 5.2V
14.6V to 15.1V
-4.8V to -5.4V
-14.4V to -15.5V
5.1V to 5.2V
24.0V to 24.1V
-14.4V to -15.5V
14.4V to 15.5V
5.1V to 5.2V
12.0V to 12.1V
-4.8V to -5.4V
-11.5V to -12.5V
1
2
Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum.
Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3
MAP80-1012 output currents are expressed as 12V/15V operation. MAP80-1024 output currents are expressed as 24V/28V operation.
4
Peak loads up to 90 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 90 Watts.
5
Output rated 65 W max for 50°C ambient, convection cooled.
6
Output rated 75 W max for 50°C ambient, convection cooled.
7
Non-G models use lead solder exemption and are not recommended for new designs.
tech.support@psbel.com
MAP80 Series
PARAMETER
Input Voltage - AC
Input Frequency
Brown Out Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Operating Frequency
3
CONDITIONS / DESCRIPTION
Continuous input range
AC input
Lowest AC input voltage that regulation is maintained with full rated
loads.
Nominal AC input voltage (115VAC), full rated load.
90 VAC (80 W load)
110VAC (80W load)
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor, Vin = 264 VAC (one cycle), 25° C
Switching frequency of power supply (varies with load)
MIN
90
175
47
90
20
NOM
MAX
135
264
63
UNITS
VAC
Hz
VAC
ms
2.5
1.8
A
RMS
45
22
120
A
PK
kHz
PARAMETER
Efficiency
Minimum Loads
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
CONDITIONS / DESCRIPTION
Full load @ 115 VAC. Varies with distribution of loads among
outputs.
MAP80-1012
MAP80-1024
All multiple output models, main channel only
Full load, 20 MHz bandwidth.
Continuous output power, all multiple output models.
Peak output power (60s maximum, 10% duty cycle), all multiple
output models.
Output voltage overshoot/undershoot at turn-on, V1, V2.
Varies by output. Total regulation includes: line changes from
90-132 VAC or 175-264, changes in load starting at 20% load and
changing to 100% load.
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation. (Main output of multiple output
units).
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
MIN
NOM
73% typical
MAX
UNITS
0.42
0.21
1.50
See Model Selection Chart
80
90
1
See Model Selection Chart
Amps
Watts
%
Transient Response
Turn-on Delay
Turn-on Rise Time
500
1
5
20
μs
Sec
ms
PARAMETER
Overvoltage Protection
Overload Protection
Power Fail Warning
8
8
CONDITIONS/DESCRIPTION
Provided on the main output of multiple output units.
MAP80-1012
MAP80-1024
Fully protected against output overload and short circuit.
Automatic recovery upon removal of overload condition.
TTL compatible logic signal. Time before regulation dropout due
to loss of input power at 110 VAC.
MIN
5.5
17.5
32
NOM
MAX
6.8
23
37
UNITS
V
4
ms
Power Fail Warning is not available for MAP80-1024. The MAP80-1012 is an open collector output, capable of sinking 35 mA, maximum
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
BCD.00565_AD
© 2016 Bel Power Solutions & Protection
4
MAP80 Series
CONDITIONS / DESCRIPTION
Approved to the latest edition of the following standards;
UL/CSA60950-1 2nd, IEC60950-1 2nd and EN60950-1 2nd.
Input to Chassis
Input to Output (tested by manufacturer only)
FCC CFR title 47 Part 15 Sub-Part B - conducted & radiated.
EN55022 / CISPR 22 conducted.
EN55022 / CISPR 22 radiated.
Line to Line
EN61000-4-5 Level 3
Line to Ground
Input to output
Per EN60950, 264 VAC
PARAMETER
Agency Approvals
Dielectric Withstand Voltage
Electromagnetic Interference,
Conducted
Input Transient Protection
Insulation Resistance
Leakage Current
MIN
NOM
MAX
UNITS
2121
4242
B
B
B
1
2
7
500
VDC
Class
kV
MΩ
μA
PARAMETER
Altitude
Operating Temperature
9
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
9
CONDITIONS / DESCRIPTION
Operating
Non-operating
Derate linearly above 50°C by 2.5% per
°C
to a maximum temperature of 70°C
MIN
NOM
MAX
10k
40k
50
70
85
UNITS
ASL Feet
°C
°C
%/°C
%RH
G
G
RMS
At 100% load:
At 50% load:
0
0
-40
0°C to 70°C (after 15 minute warm-up)
Non-condensing
Operating, peak acceleration
Random vibration, 10Hz to 2kHz, 3 axis
5
±0.02
±0.03
95
20
6
The use of an external cooling fan (100LFM (linear feet per minute), minimum) shall be determined at end use if the 25°C ambient is exceeded.
PARAMETER
Dimensions
Weight
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
mm
in
kg
lb
182.9 x 106.7 x 45.7
7.2 x 4.2 x 1.8
0.82
1.8
Order the cover number 412-59585-G separately.
For convection cooled applications, derate output power to 65 watts
on all multiple output models and MAP80-1005. Derate MAP80-
1012 and MAP80-1024 to 75 watts.
Dimensions:
182.9 x 106.7 x 50.0
7.20 x 4.20 x 1.97
Cover (Option)
mm
in
tech.support@psbel.com
MAP80 Series
CONNECTOR
Input & Output Connectors
Matting Connectors
Chassis
5
CONDITIONS / DESCRIPTION
6-32 screw wire clamps on 0.312" (7.9 mm) centers,
0.045" (1.1 mm) square pins on 0.156" (3.9 mm) centers, mates with Molex series 2139, 6442, or 41695
J1: 0.035" (0.9 mm) square pins on 0.100" (2.5 mm) centers, mates with Molex series 2695/6471
0.090" (2.3 mm) aluminum alloy, with clear finish
Figure 1. Mechanical Drawing
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
BCD.00565_AD
© 2016 Bel Power Solutions & Protection