Connectors for Copper Conductors
Two-Way Splice Connectors – Standard Barrel
Certified to 600V
and Recommended up to 35 kV
¥
C o m p r e s s i o n
Material:
Finish:
High-Conductivity
Wrought Copper
Electro Tin Plate
E
A
Two-way connectors provide high pullout values, are easy to
insulate and provide a low-resistance connection of high quality
and low installed cost.
CAT. NO.
54504
54505
54506
54507
54508
54509
54510
54511
53962
54512
54513
53964
54514
54515
54516
53968
54518
54520
54522-TB
53969
54523-TB
54528
54530
WIRE SIZE
Code
Flex Class G, H, I, K, M*
Dimensions in. (mm)
A
B
Die Set
Cat. No.
Color
Code
#8 AWG
#6 AWG
#4 AWG
#2 AWG
#1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
250 kcmil
300 kcmil
350 kcmil
400 kcmil
500 kcmil
600 kcmil
700 kcmil
750 kcmil
1000 kcmil
1250 kcmil
#8 AWG, 37/24, #8 Weld
#6 AWG, 61/24, #6 Weld, 133/0.014
#4 AWG, 91/24, 133/0.0177, 49/0.029
125/24, #4 Weld
#2 AWG, 150/24, 175/24, #2 Weld, 133/0.0223
225/24, #1 Weld, 133/0.0254
1/0 AWG, 275/24, 1/0 Weld, 427/0.0155, 133/0.0282
2/0 AWG, 325/24, 2/0 Weld, 133/0.0316, 259/0.0227, 427/0.0177
375/24, 179 kcmil, 133/0.0355, 259/0.0255, 427/0.0199
3/0 AWG, 450/24, 3/0 Weld, 703/0.0154
4/0 AWG, 550/24, 4/0 Weld, 133/0.0399, 259/0.0286, 637/0.0183
4/0 AWG, 550/24, 4/0 Weld, 133/0.0399, 259/0.0286, 637/0.0183
–
–
–
300 kcmil, 775/24 (313 kcmil)
–
–
–
1325/24 = 500/535 kcmil, 427/0.0342
–
–
–
1.00 (25.4)
1.00 (25.4)
1.00 (25.4)
1.25 (31.8)
1.50 (38.1)
1.63 (41.4)
1.75 (44.5)
1.75 (44.5)
1.81 (46.0)
1.88 (47.8)
2.25 (57.2)
2.13 (54.1)
2.13 (54.1)
2.25 (57.2)
2.75 (69.9)
3.00 (76.2)
2.75 (69.9)
3.00 (76.2)
3.25 (82.6)
3.00 (76.2)
3.00 (76.2)
3.63 (92.2)
4.13 (104.9)
0.27 (6.9)
0.30 (7.6)
0.37 (9.4)
0.41 (10.4)
0.47 (11.9)
0.52 (13.2)
0.57 (14.5)
0.63 (16.0)
0.70 (17.8)
0.70 (17.8)
0.77 (19.6)
0.79 (20.1)
0.83 (21.1)
0.90 (22.9)
0.93 (23.6)
1.13 (28.7)
1.11 (28.2)
1.18 (30.0)
1.23 (31.2)
1.24 (31.5)
1.30 (33.0)
1.50 (38.1)
1.67 42.4)
21
24
29
33
37
42
45
50
50
54
62
62
66
71
76
87
87
94
99
99
106
125
140
Red
Blue
Grey
Brown
Green
Pink
Black
Orange
Orange
Purple
Yellow
Yellow
White
Red
Blue
Brown
Brown
Green
Pink
Pink
Black
N/A
N/A
*Contact Technical Services for specific stranding listings.
Tooling: pp. 116–145
Die Selector Chart: pp.146–153
¥ For installations from 16 kV up to 35 kV, consult shielded cable manufacturers for stress relief and insulation requirements.
Two-Way Splice Connectors – Long Barrel Certified to 600V and
Recommended up to 35 kV
¥
Applications
Material:
Finish:
CAT. NO.
54804
54805
54806
54807
54808
54809
54810
54811
54812
54813
High-Conductivity
Wrought Copper
Electro Tin Plate
WIRE SIZE
Code
Flex Class G, H, I, K, M
A
A
PURPLE
PURPLE
PURPLE
PURPLE
54 DIE
54 DIE
54 DIE
54 DIE
T&B
4/0
E DIA.
Dimensions in. (mm)
E
Die
Code
Color
Code
CAT. NO.
54814
54815
54816
54818
54820
54823
58524
58526*
54828
54833
54839
WIRE SIZE
Code
Dimensions in. (mm)
#8 AWG
#6 AWG
#4 AWG
#2 AWG
#1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
250 kcmil
#8, 37/24 = 14.9 kcmil
#6, 61/24 = 24.6 kcmil
#4, 91/24 = 36.7 kcmil
125/24 = 50.4 kcmil
#2, 150/24 = 60.5 kcmil
175/24 = 70.6 kcmil
225/24 = 90.8 kcmil
1/0, 275/24 = 111 kcmil
2/0, 325/24 = 131 kcmil
450/24 = 182 kcmil
4/0, 550/24 = 222 kcmil
1.75 (44.5) 0.27 (6.9)
1.75 (44.5) 0.31 (7.9)
1.75 (44.5) 0.39 (9.9)
1.88 (47.8) 0.43 (11.0)
2.00 (50.8) 0.49 (12.4)
2.00 (50.8)
2.13 (54.1)
2.25 (57.2)
2.75 (69.9)
3.38 (85.9)
0.54 (13.7)
0.59 (15.0)
0.65 (16.5)
0.72 (18.3)
0.79 (20.1)
21
24
29
33
37
42
45
50
54
62
Red
Blue
Grey
Brown
Green
Pink
Black
Orange
Purple
Yellow
300 kcmil
350 kcmil
400 kcmil
500 kcmil
600 kcmil
750 kcmil
900 kcmil
1000 kcmil
1500 kcmil
2000 kcmil
Flex Class G, H, I, K, M
250, 650/24 = 262 kcmil
–
775/24 = 313 kcmil
350, 925/24 = 373 kcmil
1100/24 = 444 kcmil
500, 1325/24 = 535 kcmil
1600/24 = 646 kcmil
750, 1925/24 = 777 kcmil
–
–
–
A
3.50 (88.9)
3.75 (95.3)
3.75 (95.3)
4.75 (120.6)
4.25 (108.0)
4.75 (120.6)
5.00 (127.0)
5.50 (139.7)
5.63 (143.0)
5.63 (143.0)
7.06 (179.3)
Die Color
Code Code
E
0.87 (22.1) 66
White
0.95 (24.1) 71
Red
0.98 (24.9) 76
Blue
1.11 (28.2) 87
Brown
1.21 (30.7) 94
Green
1.34 (34.0) 106
Black
1.39 (35.3) 106
Black
1.51 (38.4) 115
Yellow
1.56 (39.6) 125
N/A
1.56 (39.6) 125
N/A
2.13 (54.1)
–
N/A
¥ For installations from 16 kV up to 35 kV, consult shielded cable
manufacturers for stress relief and insulation requirements.
*CSA approved code cable only
Tooling: pp. 116–145
Die Selector Chart: pp. 146–153
¥ For installations from 16 kV up to 35 kV, consult shielded
cable manufacturers for stress relief and insulation
requirements.
48