Data sheet
VG Exi 4J (Ex plastic cable gland 4J Exi)
VG M20 EXI BL
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
www.weidmueller.com
Polyamide cable glands, which are suitable for usage
in explosion risk zones Ex e (increased safety) and Ex i
(intrinsic safety).
On account of the enhanced EN60079-0:2009 testing
requirements, there is now a version update of the
standard (EN60079-0:2012) available.
Weidmüller offers a product family without restrictions
and besides compliance with standards, the cable gland
excels thanks to its increased impact resistance of 7 Joule
and a possible temperature range down to -60°C without
restrictions.
They have been tested to the current standard and EN
60079-0:2012 directive, and besides EAC, they are ATEX
and IECEx certified.
General ordering data
Type
Order No.
Version
GTIN (EAN)
Qty.
VG M20 EXI BL
1461050000
VG Exi 4J (Ex plastic cable gland 4J Exi), Cable
glands, M 20, 10 mm, OD min. 6 - OD max. 12
mm, IP54, IP66, IP67, IP68 - 5 bar (30 min.),
Polyamide 6
4050118267228
20 pc(s).
Creation date May 14, 2019 5:18:25 PM CEST
Catalogue status 01.05.2019 / We reserve the right to make technical changes.
1
Data sheet
VG Exi 4J (Ex plastic cable gland 4J Exi)
VG M20 EXI BL
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
www.weidmueller.com
Technical data
10.95 g
Dimensions and weights
Net weight
Certificate numbers cable gland
Identification
Certificate no. cable gland (IECEx)
Ex e llC Gb, Ex tb IIIC Db
IP66/68
IECEx IMQ 13.0003X
Certificate no. cable gland (ATEX)
Certificate no. cable gland (EAC)
IMQ 13 ATEX 010 X
RU C-TR 05.B04161
General information
AF size 1
Cable glands
External thread
Installation guidelines
Material
Operating temperature range, min.
Outer cable diameter, min.
Protection degree
Seal insert
24 mm
metric
M 20
See assembly instructions
Polyamide 6
-40 °C
6 mm
IP54, IP66, IP67, IP68 - 5
bar (30 min.)
AF size 2
Explosion protection type
Impact resistance
Length of thread
Operating temperature range, max.
Outer cable diameter, max.
Pitch of thread
Protection degree with GWDR
Standards
UL 94 flammability rating
CR
HB
24 mm
Intrinsically safe Ex i
4 J ATEX version
10 mm
80 °C
12 mm
1.5 mm
IP54, IP66, IP67, IP68 - 5
bar (30 min.)
EN 60079-0 : 2009,
EN 60079-7 : 2007, EN
60079-31 : 2009, IEC
60079-0, IEC 60079-7,
IEC 60079-31
Classifications
ETIM 6.0
eClass 7.1
eClass 9.0
EC000441
27-14-91-11
27-14-44-32
eClass 6.2
eClass 8.1
eClass 9.1
27-14-91-11
27-14-91-11
27-14-44-34
Approvals
Approvals
ROHS
CE; EAC; ATEX; IECEX; INMETRO
Conform
Downloads
Engineering Data
Engineering Data
EPLAN, WSCAD
STEP
Creation date May 14, 2019 5:18:25 PM CEST
Catalogue status 01.05.2019 / We reserve the right to make technical changes.
2