603 SERIES EMC
PANEL INDICATOR LED
FEATURES
•
•
•
•
•
•
•
EMC mesh under lens
Ø5.0mm mounting
Bright nickel plated brass housing
Sealed to IP67 - weatherproof
Colour diffused lens
Internal potting
Range of LED colour options
BENEFITS
•
•
•
•
•
•
•
•
•
Protects against EMI/RFI
Standard industrial mounting size
Suitable for harsh environments
Suitable for external applications
Wide viewing angle
Suitable for high vibration applications
Suitable for status panel indication
Outstanding reliability
Vandal resistant
Marl Part
Number
LED Colour
Red
Yellow
Green
Blue
Cool White
Red (Standard Intensity)
Yellow (Standard Intensity)
Green (Standard Intensity)
603-301-04-58
603-325-04-58
603-324-04-58
603-934-04-58
603-998-04-58
603-303-04-58
603-309-04-58
603-312-04-58
Typical Voltage
DC Vf
1.85
2.0
3.2
3.2
3.2
2.0
2.1
2.2
Vdc
Typical Current
If
20
20
20
20
20
20
20
20
mA
Typical LED
Luminous
Intensity
900
2800
36100
6550
12900
131
43
131
mcd
Typical LED
Wavelength
λp
660
590
525
465
See Below
627
590
565
nm
Operating
Temp
Topr *
-40 to +85
-40 to +85
-30 to +85
-30 to +85
-30 to +85
-40 to +85
-40 to +85
-40 to +85
°C
Storage
Temp
Tstg
-40 to +85
-40 to +85
-40 to +100
-40 to +100
-40 to +100
-40 to +85
-40 to +85
-40 to +85
°C
Typical Emission Colours Cool White LED
X
Y
0.296
0.276
0.283
0.305
0.330
0.360
0.330
0.318
NOTES
Intensities (lv) and colour shades of white (X-Y co-ordinates) may vary between LEDs within a batch. Additional LED Colours, Voltage Options and Flying Lead lengths available for semi-
custom projects. Please contact our Sales Team. All LED components are supplied in anti-static packaging.
* Characteristics at Ta = 25°C. For operating temperature derating graphs, please refer to sheet 2.
To order please contact us on +44 (0) 1229 582 430
F +44 (0) 1229 585 155
|
E sales@marl.co.uk
| www.leds.co.uk
marlleds
marlinternationallimited
company/marl-international-limited
Q 05480
DSN 603EMC Version DS015/2016. Page 1 of 2
603 SERIES EMC
PANEL INDICATOR LED
TECHNICAL CHARACTERISTICS
Series
603
Max. Power
Dissipation
425
mW
Max. Reverse Voltage
5
Vdc
Panel Cutout
5.0
mm
Nut Mounting
Torque
0.35
Nm
Min. Mounting
Centres
10.0
mm
Min. - Max. Panel
Thickness
1.5 - 8.0
mm
Weight (g): 1.75
Dimensions in mm (typical). Not to scale. Mounting hole to be clean and burr free. Anode termination denoted by red indicator.
TECHNICAL DRAWING
PUSH ON CONNECTOR
11.8
0.45 Typ.
2.5
15.2
7.9
5.1
1.4
5
+ 0.1
0
2
12.0 Min.
1.2 Typ.
Mounting hole
909-000-00 is gold plated, 910-000-00 is tim plated - for use
with 603 series lamps.
Dimensions in mm (typical). Not to scale.
DE-RATING GRAPHS
Red / Yellow High Intensity LED
Forward Current If (mA)
50
40
30
20
10
0
Blue / Green High Intensity LED
Forward Current If (mA)
50
40
30
20
10
8.5
Cool White High Intensity LED
Forward Current If (mA)
50
40
30
20
10
8.5
0
20
40
60
80
100
0
0
20
40
60
80
100
0
0
20
40
60
80
100
Ambient Temperature Ta (°C)
Ambient Temperature Ta (°C)
Ambient Temperature Ta (°C)
Forward Current If (mA)
Forward Current If (mA)
40
30
20
10
0
40
30
20
10
0
Forward Current If (mA)
20
40
60
80
100
50
Red Standard Intensity LED
Yellow Standard Intensity LED
50
Green Standard Intensity LED
50
40
30
20
10
0
0
20
40
60
80
100
0
0
20
40
60
80
100
Ambient Temperature Ta (°C)
Ambient Temperature Ta (°C)
Ambient Temperature Ta (°C)
MATERIALS
Body
Nut
Panel Seal
Fresnel Lens
Bright Nickel Plated Brass
Bright Nickel Plated Brass
Viton
Polycarbonate
Encapsulation
Lock Washer
EMC Mesh
Termination
Black Polyurethane
Beryllium Copper
Stainless Steel
LED Leads
it is operated. Therefore, care must be taken to operate the
LED at the correct voltage / current values, depending upon
the ambient temperature.
Electro-Static Discharge (ESD)
Build up of electro-static discharge occurs in many situations
involving people moving and handling products.The range
of possible situations is very diverse but voltage levels as
high as several thousand volts can and do arise in many
individual situations. When an operator charged up to these
levels handles a static sensitive device, there is a very
probable likelihood that the device will be irreversibly
damaged. It is essential that precautions are taken at all
stages during manufacture and assembly of these products.
Although LEDs were never considered to be static sensitive
DESIGN CONSIDERATIONS
devices, changes in manufacturing technology and
materials used to produce higher intensity products over a
large range of the wavelength spectrum have changed this.
Marl has an approved system of ESD control from goods
in, through production and into final packing and despatch.
Marl recommend all users of LED based products follow the
guidelines of BS 100015.
Voltage, Current and Temperature
The forward voltage / current value of an LED is dependent
upon the ambient temperature of the environment in which
Marl should be contacted if the device is to be operated
outside the temperature range specified. Marl accept no
liability for any product that is operated outside the stated
voltage or temperature range.
To order please contact us on +44 (0) 1229 582 430
F +44 (0) 1229 585 155
|
E sales@marl.co.uk
| www.leds.co.uk
marlleds
marlinternationallimited
company/marl-international-limited
Q 05480
DSN 603EMC Version DS015/2016. Page 2 of 2