It is recommended that the temperature of the component does not exceed +125 °C under worst
case conditions
Ambient Temperature (referring
to I
R
)
Operating Temperature
Storage Conditions (in original
packaging)
Moisture Sensitivity Level (MSL)
Scale - 2:1
-40 up to +85 °C
-40 up to +125 °C
< 40 °C ; < 75 % RH
1
11 max.
Test conditions of Electrical Properties: +20 °C, 33 % RH if not specified differently
Product Marking:
Start of Winding
Marking
•
CHECKED
REVISION
DATE (YYYY-MM-DD)
GENERAL TOLERANCE
221 (Inductance Code)
PROJECTION
METHOD
ThR
DESCRIPTION
004.002
2020-05-18
DIN ISO 2768-1m
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
WE-TIS Shielded Radial Leaded
Wire Wound Inductor
SIZE/TYPE
BUSINESS UNIT
ORDER CODE
7447471221
STATUS
PAGE
1111
eiSos
Valid
1/6
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.
Typical Inductance vs. Current Characteristics:
250
Typical Impedance Characteristics:
100000
200
10000
Impedance [Ω]
Inductance [µH]
150
1000
100
100
10
50
1
0
0.0
0.5
1.0
1.5
2.0
Current [A]
2.5
3.0
3.5
1
10
100
1000
10000
Frequency [MHz]
Z
CHECKED
REVISION
DATE (YYYY-MM-DD)
GENERAL TOLERANCE
PROJECTION
METHOD
ThR
DESCRIPTION
004.002
2020-05-18
DIN ISO 2768-1m
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
WE-TIS Shielded Radial Leaded
Wire Wound Inductor
SIZE/TYPE
BUSINESS UNIT
ORDER CODE
7447471221
STATUS
PAGE
1111
eiSos
Valid
2/6
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.
Packaging Specification - Tray: [mm]
A0
T
A0
B0
P3
B0
Top Cover
Tray
10x P2
4x P0
P1
A0
typ.
245.00
B0
typ
195.00
T
ref.
10.00
Top Cover
PET
tolerance
size
1111
A0
typ.
244.00
B0
typ.
194.00
P0
ref.
45.50
P1
ref.
182.00
P2
ref.
16.30
P3
ref.
163.00
T
ref.
9.80
Tray
PET
VPE / packaging unit
pcs.
110
tolerance
size
1111
CHECKED
REVISION
DATE (YYYY-MM-DD)
GENERAL TOLERANCE
PROJECTION
METHOD
ThR
DESCRIPTION
004.002
2020-05-18
DIN ISO 2768-1m
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
WE-TIS Shielded Radial Leaded
Wire Wound Inductor
SIZE/TYPE
BUSINESS UNIT
ORDER CODE
7447471221
STATUS
PAGE
1111
eiSos
Valid
T
3/6
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.
Classification Wave Soldering Profile:
t
p
T
p
Classification Wave Soldering Profile:
Profile Feature
Preheat Temperature Min
Preheat Temperature Typical
T
s min
T
s max
t
s
ΔT
T
p
t
p
Pb-Free Assembly
100 °C
130 °C
70 seconds
150 °C max.
250 °C - 260 °C
max. 10 seconds
max. 5 seconds each wave
~ 2 K/ second
~ 3.5 K/ second
~ 5 K/ second
4 minutes
T
s typical
120 °C
Sn-Pb Assembly
100 °C
120 °C
130 °C
70 seconds
150 °C max.
235 °C - 260 °C
max. 10 seconds
max. 5 seconds each wave
~ 2 K/ second
~ 3.5 K/ second
~ 5 K/ second
4 minutes
First Wave
Second Wave
Preheat Temperature Max
Preheat Time t
s
from T
s min
to T
s max
Ramp-up Rate
Peak Temperature
Temperature
Time of actual peak temperature
T
s max
T
s typical
T
s min
Ramp-down Rate, Min
Ramp-down Rate, Typical
Ramp-down Rate, Max
Time 25 °C to 25 °C
refer to EN61760-1:2006
Preheat area
Cool down area
Time
typical temperature procedure
min temperature procedure
max temperature procedure
CHECKED
REVISION
DATE (YYYY-MM-DD)
GENERAL TOLERANCE
PROJECTION
METHOD
ThR
DESCRIPTION
004.002
2020-05-18
DIN ISO 2768-1m
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
WE-TIS Shielded Radial Leaded
Wire Wound Inductor
SIZE/TYPE
BUSINESS UNIT
ORDER CODE
7447471221
STATUS
PAGE
1111
eiSos
Valid
4/6
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.
Cautions and Warnings:
The following conditions apply to all goods within the product series of WE-TIS ofWürth
Elektronik eiSos GmbH & Co. KG:
General:
• This electronic component is designed and manufactured for use in general electronic equipment.
• Würth Elektronik must be asked for written approval (following the PPAP procedure) before incorporating the components into any
equipment in fields such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control,
ship control), transportation signal, disaster prevention, medical, public information network, etc. where higher safety and reliability are
especially required and/or if there is the possibility of direct damage or human injury.
• Electronic components that will be used in safety-critical or high-reliability applications, should be pre-evaluated by the customer.
• The component is designed and manufactured to be used within the datasheet specified values. If the usage and operation conditions
specified in the datasheet are not met, the wire insulation may be damaged or dissolved.
• Do not drop or impact the components, the component may be damaged.
• Würth Elektronik products are qualified according to international standards, which are listed in each product reliability report. Würth
Elektronik does not warrant any customer qualified product characteristics beyond Würth Elektroniks’ specifications, for its validity and
sustainability over time.
• The responsibility for the applicability of the customer specific products and use in a particular customer design is always within the
authority of the customer. All technical specifications for standard products also apply to customer specific products.
Storage Conditions:
• A storage of Würth Elektronik products for longer than 12 months is not recommended. Within other effects, the terminals may suffer
degradation, resulting in bad solderability. Therefore, all products shall be used within the period of 12 months based on the day of
shipment.
• Do not expose the components to direct sunlight.
• The storage conditions in the original packaging are defined according to DIN EN 61760-2.
• The storage conditions stated in the original packaging apply to the storage time and not to the transportation time of the components.
Handling:
• Violation of the technical product specifications such as exceeding the nominal rated current will void the warranty.
• Applying currents with audio-frequency signals may result in audible noise due to the magnetostrictive material properties.
• Due to heavy weight of the components, strong forces and high accelerations may have the effect to damage the electrical connection
or to harm the circuit board and will void the warranty.
These cautions and warnings comply with the state of the scientific and technical knowledge and are believed to be accurate and reliable.
However, no responsibility is assumed for inaccuracies or incompleteness.
Product specific:
Soldering:
• The solder profile must comply with the technical product specifications. All other profiles will void the warranty.
• All other soldering methods are at the customers’ own risk.
Cleaning and Washing:
• Washing agents used during the production to clean the customer application might damage or change the characteristics of the wire
insulation, marking or plating. Washing agents may have a negative effect on the long-term functionality of the product.
Potting:
• If the product is potted in the customer application, the potting material might shrink or expand during and after hardening. Shrinking
could lead to an incomplete seal, allowing contaminants into the core. Expansion could damage the component. We recommend a
manual inspection after potting to avoid these effects.
CHECKED
REVISION
DATE (YYYY-MM-DD)
GENERAL TOLERANCE
PROJECTION
METHOD
ThR
DESCRIPTION
004.002
2020-05-18
DIN ISO 2768-1m
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
WE-TIS Shielded Radial Leaded
Wire Wound Inductor
SIZE/TYPE
BUSINESS UNIT
ORDER CODE
7447471221
STATUS
PAGE
1111
eiSos
Valid
5/6
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.