Synthesizer , SMT
1046 — 1085 MHz, 200 kHz
Features
♦
Fully Integrated VCO, PLL, Loop Filter
♦
High Performance, Low Cost
♦
Miniature SMT Package (LSM6)
MASYVS0061-1066
Rev: E
Description
This synthesizer design integrates a high performance VCO, PLL,
IC and discrete loop filter in a surface mount package. This SMT
package provides electrical shielding, easy PCB assembly and re-
peatable performance. The synthesizer is designed for use in wire-
less base stations.
M/A-COM synthesizers are manufactured in an ISO9001 certified
facility, incorporating surface mount assembly and automated elec-
trical testing. This ensures consistent electrical performance and
quality over volume production quantities.
Electrical Specifications
1
:
T
A
= +25°C, Z
0
= 50 Ohms, F
ref
= 10MHz, V
cc1
= 5V, V
cc2
= 3.3V.
Parameter
Frequency Range
RF Output Power
Phase Noise
Test Conditions
Over T
op 2
Over T
op 2
SSB at 600 kHz offset from carrier
SSB at 800 kHz offset from carrier
SSB at 1800 kHz offset from carrier
SSB at 6000 kHz offset from carrier
Units
MHz
dBm
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc
Phase comparison frequency ( ± 200 kHz)
± 400 kHz
± 600 kHz
± 800 kHz
Reference breakthrough ( ± 10 MHz)
Over F
out
, Measured to within ± 4 degrees
Measured over 577υs time slot
Measured over 577υs time slot
Recommended operating condition
Recommended operating condition
Recommended operating condition
Recommended operating condition
dBc
dBc
dBc
dBc
dBc
υs
Degree
Degree
mA
mA
V
V
+4.75
+3.1
0.6
1.7
47
13
+5.00
+3.3
Min
1046
+2.5
-145
-151
-153
-160
-33
-85
-87
-93
-97
-100
Typ
Max
1085
+7.5
-144
-148
-151
-157
-20
-79
-84
-90
-95
-97
450
1.0
4
55
15
+5.25
+3.5
Harmonic Suppression
Spurious Suppression
(Non-Harmonic)
Frequency Lock Time
Phase Error (rms)
Phase Error (peak)
VCO Supply Current (I
CC1
)
PLL Supply Current (I
CC2
)
VCO Power Supply (V
CC1
)
PLL Power Supply (V
CC2
)
1. All specification limits are indicated values @ +25 ºC and apply over F
out
unless otherwise stated.
2. T
op
= -40ºC to +85ºC operating temperature.
1
M/A-COM Inc. and its affiliates reserve the right to make changes to
the product(s) or information contained herein without notice. M/A-
COM makes no warranty, representation or guarantee regarding the
suitability of its products for any particular purpose, nor does M/A-
COM assume any liability whatsoever arising out of the use.
or application of any product(s) or information.
•
North America
Tel: 800.366.2266 / Fax: 978.366.2266
•
Europe
Tel: 44.1908.574.200 / Fax: 44.1908.574.300
•
Asia/Pacific
Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit
www.macom.com
for additional data sheets and product information.
Synthesizer , SMT
1046 — 1085 MHz, 200 kHz
Electrical Specifications
1
: (cont’d)
Parameter
Step Size (∆F)
Reference Frequency (F
R
)
PLL Programming
PLL Lock Monitor Output
Test Conditions
Recommended operating limit
1.0 V pp ± 0.2V square wave with input filter
Units
kHz
MHz
MASYVS0061-1066
Min
Typ
200
Max
10
100
3-wire serial CMOS IAW ADF4113, Charge Pump 5 mA
Logic high = V
CC2
x 0.8 Min and Logic low = V
CC2
x 0.2 Max
Locked = V
CC2
- 0.4 Min , Unlocked = 0.4V Max
Pin Configuration
Pin No.
1
2
3
4
5
6
7
Function
V
CC1
GND
REF I/P
GND
V
CC2
GND
RF O/P
Pin No.
8
9
10
11
12
13
14
Function
GND
Lock Detect
Clock
Data
Load Enable
GND
GND
Absolute Maximum Ratings
T
A
= +25°C
Parameter
VCO Supply Voltage (V
CC1
)
PLL Supply Voltage (V
CC1
)
Reference Frequency Level
Data, Clock, Strobe
Voltages
Operating Temperature
Storage Temperature
Solder Assembly
Temperature
Absolute Maximum
-0.3V to 6.5 V
-0.3V to 6.5 V
-0.3V to 6.5 V
-0.3V to V
cc
+ 0.3 V
-40°C to +85°C
-45°C to +120°C
See App Note M2032
Functional Block Diagram
1. Operation of this device above any one of these parameters
may cause permanent damage.
2. Static sensitive, observe appropriate handling precautions.
Environmental Specifications
Devices are designed to function after exposure to the
shock, vibration, thermal shock and moisture conditions
typically encountered in base station and other infra-
structure environments.
Ordering Information
Part Number
MASYVS0061-1066 B
1. The diagram above shows a typical application.
2. The Reference input and RF output are internally AC cou-
pled.
3. The diagram applies when digital lock detect is selected. For
analog open-drain mode, a filter is required. See AN3003 for
design information.
MASYVS0061-1066 T
MASYVS0061-1066 R
Package
Bulk Packaging
Tape and Reel (300/Reel)
1
Reverse Tape and Reel
(300/Reel)
1
1. See application note M513.
2
M/A-COM Inc. and its affiliates reserve the right to make changes to
the product(s) or information contained herein without notice. M/A-
COM makes no warranty, representation or guarantee regarding the
suitability of its products for any particular purpose, nor does M/A-
COM assume any liability whatsoever arising out of the use.
or application of any product(s) or information.
•
North America
Tel: 800.366.2266 / Fax: 978.366.2266
•
Europe
Tel: 44.1908.574.200 / Fax: 44.1908.574.300
•
Asia/Pacific
Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit
www.macom.com
for additional data sheets and product information.
Synthesizer , SMT
1046 — 1085 MHz, 200 kHz
Recommended PCB Layout
MASYVS0061-1066
Outline Drawing
3
M/A-COM Inc. and its affiliates reserve the right to make changes to
the product(s) or information contained herein without notice. M/A-
COM makes no warranty, representation or guarantee regarding the
suitability of its products for any particular purpose, nor does M/A-
COM assume any liability whatsoever arising out of the use.
or application of any product(s) or information.
•
North America
Tel: 800.366.2266 / Fax: 978.366.2266
•
Europe
Tel: 44.1908.574.200 / Fax: 44.1908.574.300
•
Asia/Pacific
Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit
www.macom.com
for additional data sheets and product information.