05186
PAC-95
thru
PAC-240
AC POWERLINE TVS COMPONENT
APPLICATIONS
✔
AC Power Mains
✔
Module Lightning Protection
IEC COMPATIBILITY
(EN61000-4)
✔
61000-4-5 (Surge): 8/20µs - 1kA, L4 (Line-Line) & 333A, L4 (Line-Ground)
FEATURES
RADIAL LEAD
✔
5000 to 6900 kilowatts Peak Pulse Power per Line (tp=8/20µs)
✔
Compact Module in a Bidirectional Configuration
✔
Provides Primary Protection
✔
Glass Passivated Chip
✔
Easy Mounting to Printed Circuit Board
✔
Available in 3 Voltages: 95VAC, 130VAC & 240VAC
✔
RoHS Compliant
MECHANICAL CHARACTERISTICS
✔
Epoxy Case
✔
Weight 7.2 - 11.3 grams (Approximate)
✔
Flammability rating UL 94V-0
✔
Marking: Logo & Part Number
APPLICATION
AC POWER LINE PROTECTION
90V
AC
120V
AC
240V
AC
05186.R2 2/07
1
www.protekdevices.com
PAC-95
thru
PAC-240
DEVICE CHARACTERISTICS
MAXIMUM RATINGS
@ 25°C Unless Otherwise Specified
PARAMETER
Peak Pulse Power (tp =8/20µs) - See Fig. 1
Storage Temperature
Operating Temperature
SYMBOL
P
PP
T
STG
T
L
VALUE
5000 & 6900
-40 to +125
-40 to +125
UNITS
kilowatts
0
0
C
C
ELECTRICAL CHARACTERISTICS PER LINE
PART
NUMBER
RATED
STAND-OFF
VOLTAGE
BREAKDOWN
VOLTAGE
@ 25°C Unless Otherwise Specified
MAXIMUM
LEAKAGE
CURRENT
@V
WM
I
D
µA
20
20
20
MAXIMUM
CLAMPING
VOLTAGE
TEMPERATURE
COEFFICIENT
OF V
(BR)
qV
(BR)
%/°C
0.1
0.1
0.1
V
WM
VOLTS AC
PAC-95
PAC-130
PAC-240
95
130
240
V
WM
VOLTS DC
135
202
380
MIN
V
(BR)
VOLTS DC
157
214
400
@I
T
mA
1
1
1
@ 8/20µs
V
C
@ I
PP
299V @ 16kA
378V @ 16kA
692V @ 10kA
05186.R2 2/07
2
www.protekdevices.com
PAC-95
thru
PAC-240
GRAPHS
FIGURE 1
PEAK PULSE POWER VS PULSE TIME
100,000
P
PP
- Peak Pulse Power - kilowatts
10,000
5000kW 8/20µs
Waveform
1000
6900kW 8/20µs
Waveform
100
0.1
1
10
100
t
d
- Pulse Duration - µs
1,000
10,000
120
I
PP
- Peak Pulse Current - % of I
PP
FIGURE 2
PULSE WAVE FORM
100
t
f
Peak Value I
PP
TEST
WAVEFORM
PARAMETERS
t
f
= 8µs
t
d
= 20µs
80
% Of Rated Power
FIGURE 3
POWER DERATING CURVE
Peak Pulse Power
8/20µs
100
80
60
40
20
0
0
5
e
-t
60
40
20
Average Power
0
t
d
= t I /2
PP
10
15
t - Time - µs
20
25
30
0
25
50
75
100
125
T
L
- Lead Temperature - °C
150
05186.R2 2/07
3
www.protekdevices.com
PAC-95
thru
PAC-240
RADIAL LEAD PACKAGE OUTLINE & DIMENSIONS
90VAC RADIAL LEAD PACKAGE OUTLINE
PACKAGE DIMENSIONS
(90 VAC Device)
A
E
B
DIM
MILLIMETERS
(Nominal)
INCHES
(Nominal)
A
B
C
F
C
12.5
12.45
1.27
20.1
6.35
23.37
0.49
0.49
0.05
0.79
0.25
0.92
D
E
F
D
130 & 240 VAC RADIAL LEAD PACKAGE OUTLINE
PACKAGE DIMENSIONS
(130 & 240 VAC Devices)
MILLIMETERS
DIM
(Nominal)
INCHES
(Nominal)
A
E
B
A
B
C
F
18.12
13.72
1.25
23.722 ±1.16
7.37
20.0
0.69
0.54
0.049
0.934 ± 0.046
0.29
0.787
D
E
F
C
D
Outline & Dimensions: Rev 0 - 2/03, 06041
COPYRIGHT © ProTek Devices 2007
SPECIFICATIONS: ProTek reserves the right to change the electrical and or mechanical characteristics described herein without notice (except JEDEC).
DESIGN CHANGES: ProTek reserves the right to discontinue product lines without notice, and that the final judgement concerning selection and specifications is
the buyer’s and that in furnishing engineering and technical assistance, ProTek assumes no responsibility with respect to the selection or specifications of such
products.
ProTek Devices
2929 South Fair Lane, Tempe, AZ 85282
Tel: 602-431-8101 Fax: 602-431-2288
E-Mail: sales@protekdevices.com
Web Site: www.protekdevices.com
www.protekdevices.com
05186.R2 2/07