3120-F351-P7T1-W19QG3-14A

产品描述1 POLE(S), 14A, 250 V(AC), 50 V(DC), PANEL MOUNT, THERMAL CIRCUIT BREAKER,
产品类别电路保护    电路保护   
文件大小441KB,共5页
制造商E-T-A [E-T-A Circuit Breakers]
下载文档 详细参数 全文预览

3120-F351-P7T1-W19QG3-14A概述

1 POLE(S), 14A, 250 V(AC), 50 V(DC), PANEL MOUNT, THERMAL CIRCUIT BREAKER,

3120-F351-P7T1-W19QG3-14A规格参数

参数名称属性值
厂商名称E-T-A [E-T-A Circuit Breakers]
Reach Compliance Codecompliant
执行器类型ROCKER
主体宽度21 mm
主体高度33 mm
主体长度或直径54 mm
电路功能MANUAL ON/OFF
电路保护类型THERMAL CIRCUIT BREAKER
环境特性CORROSSION RESISTANT
安装特点PANEL MOUNT
极数1
最高工作温度60 °C
最低工作温度-30 °C
物理尺寸54mm x 21mm x 33mm
额定分断能力140 A
额定电流14 A
额定电压(交流)250 V
额定电压(直流)50 V
参考标准CCC; CSA; UL; VDE
表面贴装NO
端子形状QUICK CONNECT
Base Number Matches1

文档预览

下载PDF文档
Thermal Overcurrent Circuit Breaker 3120-F...
Description
An extremely versatile range of rocker switch/thermal circuit breakers
(S-type TO CBE to EN 60934 with trip free mechanism) offering the choice
of single pole, double pole with single pole protection, and double pole
with protection on both poles. Designed for snap-in panel mounting with
versions available for three different panel cut-out sizes. Illumination is
optional and there is a range of colours and markings for the rocker.
Add on modules:
Under voltage release coil (for double pole versions only).
Magnetic trip coil for short circuit protection.
Magnetic trip coil for remote relay trip.
Auxiliary contacts for status signalling.
Approved to CBE standard EN 60934 (IEC 60934).
Meets the requirements regarding fire resistance of EN 60335-1 : 2007-02
Safety of household and similar electrical appliances.
3120-F3...F5
Typical applications
Technical data
Motors, transformers, solenoids, extra low voltage wiring systems, office
machines, electro-medical equipment, power supplies, communications
systems, medical equipment to EN 60601.
Standard current ratings and typical internal resistance values
Current rating
(A)
0.1
0.2
0.3
0.4
0.5
0.6
0.8
1
1.2
1.5
2
2.5
3
3.5
Internal
resistance
per pole (Ω)
94
24
12
5.30
4.20
2.90
1.50
0.9
0.80
0.45
0.27
0.0785
0.0595
0.0565
Current rating
(A)
4
4.5
5
6
7
8
10
12
14
15
16
18
20
Internal
resistance
per pole (Ω)
0.0435
0.0435
0.0325
0.0215
0.0165
0.0165
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
Dielectric strength
(IEC 60664 and 60664A)
operating area
between poles (2-pole)
Insulation resistance
Interrupting capacity I
cn
3120-F7
2
For further details please see chapter: Technical Information
Voltage rating
AC 240 V; DC 50 V
(AC 415 V to special order)
(UL: AC 250 V; DC 50 V)
Current ratings
0.1...20 A
(up to 30 A to special order, single pole only)
Typical life
AC 240 V:
DC 50 V:
DC 28 V:
AC 415 V:
AC 240 V:
0.1...20 A
0.1...4 A
4.5...16 A
0.1...20 A
0.1...16 A
0.1...16 A
17...20 A
DC 50 V:
0.1...16 A
17...20 A
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664 A
1-pole
30,000 operations at 1 x I
N
, inductive
30,000 operations at 1 x I
N
, inductive
30,000 operations at 1 x I
N
, resistive
30,000 operations at 1 x I
N
, inductive
2-pole
10,000 operations at 1 x I
N
, inductive
50,000 operations at 1 x I
N
, inductive
30,000 operations at 1 x I
N
, inductive
50,000 operations at 1 x I
N
, inductive
10,000 operations at 1 x I
N
, inductive
-30...+60 °C (-22...+140 °F)
rated impulse
pollution
withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Illumination voltage/power consumption
operating voltage
12 V DC
24 V DC
115 V AC
230 V AC
power consumption
Y+R
2 mA
2 mA
0.9 mA
0.9 mA
G
3.5 mA
3.5 mA
2.8 mA
2.8 mA
test voltage
AC 3,000 V
AC 1,500 V
> 100 MΩ (DC 500 V)
0.1...2 A 10 x I
N
2.5...20 A 250 A 2-pole, or 150 A 1-pole
Interrupting capacity (UL 1077)
I
N
1, 2-pole
1, 2-pole
Degree of protection
(IEC 60529/DIN 40050)
Vibration
0.1...20 A
0.1...20 A
U
N
AC 250 V
DC 50 V
I
nc
5000 A
1000 A
Approvals
Authority
VDE (EN 60934)
Voltage ratings
AC 240 V; DC 28 V
DC 50 V
DC 50 V
AC 250 V; DC 50 V
AC 250 V; DC 50 V
Current ratings
0.1...20 A
0.1...20 A
2-pole
0.1...10 A
1-pole
0.1...20 A
0.1...20 A
Shock
Corrosion
Humidity
Mass
UL, CSA
CCC
operating area IP40
(IP54 with water splash protection)
terminal area IP00
8 g (57-500 Hz), ± 0.61 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
30 g (11 ms)
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
approx. 33 g (double pole)
approx. 27 g (single pole)
Issue D
www.e-t-a.de
2
- 67
大家说说德州仪器的那个无线运动手表能够水下30米的原理
记得好像手册里说德州仪器的那个无线运动手表承受水深是30米 大家能不能说说是怎样防止水进去的? 特别是有手表的,拆开过吧?能不能说说? 没有得我说说,测量大气压,好像是通过像毛细管一 ......
wangfuchong 聊聊、笑笑、闹闹
XOZ增益图好像不对劲,为什么?
用18.1仿的一个天线,从3D图看,在XOZ面上应该是全向的。但软件画出来的图好像比较奇怪,问题出在哪里? 3D图和XOZ图: 318758 318759 XOZ 2D图和 XOZ设定: 318760 3 ......
flyingwave 无线连接
静态协议栈工程的4种默认的配置
ST官方SDK中已经提供了静态协议栈的Demo: C:\Users\user name\ST\BlueNRG-LP DK 1.x.x\Projects\BLE_Examples\BLE_StaticStack 静态协议栈默认提供了4种配置: Releas ......
littleshrimp 意法半导体-低功耗射频
ISV时代我们如何破局
ISV时代我们如何破局 ——专访武汉兴图新科电子有限公司首席架构师黄少军虽然软件在安防系统中正在扮演着越来越重要的角色,但人们对软件的作用和价值的认识程度还是远远不够, ......
程序天使 工业自动化与控制
晶振在各类音响中的应用
在日益浮躁的社会,很多人都喜欢在音乐的世界放松自己,而拥有一款好的播放设备,想必是众多音乐爱好者梦寐以求的事情。 大家都知道音乐是有许多神奇的功能的,比如:分散注意力,让身体放轻 ......
zkj2014 综合技术交流
IGBT驱动芯片IXDN404应用及改进
摘要:介绍了IXYS公司大功率IGBT驱动芯片IXDN404的特点及性能,并在此基础上,根据IGBT驱动的实际要求,设计出了一种具有过流保护及慢关断功能的简单有效的驱动电路,给出了实际电路图和驱动波 ......
eeleader 工业自动化与控制

 
EEWorld订阅号

 
EEWorld服务号

 
汽车开发圈

 
机器人开发圈

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程 索引文件: 1001  884  2812  871  2840  57  59  37  58  8 

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区中关村大街18号B座15层1530室 电话:(010)82350740 邮编:100190

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved