A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
Series Datasheet – MK02 Reed Sensors
www.standexmeder.com
MK02 Series
Reed Sensors
Features: Ferrous Metal Detection, Front or Above Operation, Choice of Cable Termination & Lengths
Applications: Door & Window Control, Fire Protection Doors, Safety & Interlock Sensing & Others
Markets: Appliance, Industrial, Security & Others
Part Description:
MK 02/0-0X00-000X
Operation
Series
0, 1, 2, 3, 4
Contact
QTY
01
Contact
Form
A, B, C
Switch
Model
66, 90
Cable Length
(mm)
Termination
W
200, 300, 500, 1000, 1500,
2000, 3000, 5000
Switch Model
66
10
200
0.5
1.00
150
0.25
0.7
0.05
10
10
0.3
90
10
175
0.5
1.0
150
0.2
0.7
1.5
10
9
1.5
Customer Options
Contact Data
Rated Power (max.)
Any DC combination of V&A not to exceed their individual max.’s
Unit
W
V
A
A
mOhm
kVDC
ms
ms
GOhm
pF
Switching Voltage (max.)
DC or peak AC
Switching Current (max.)
DC or peak AC
Carry Current (max.)
DC or peak AC
Contact Resistance (max.)
@ 0.5V & 50mA
Breakdown Voltage (min.)
According to EN60255-5
Operating Time (max.)
Incl. Bounce; Measured with w/ Nominal Voltage
Release Time (max.)
Measured with no Coil Excitation
Insulation Resistance (typ.)
Rh<45%, 100V Test Voltage
Capacitance (typ.)
@ 10kHz across open Switch
USA:
Europe:
Asia:
+1.866.782.6339
+49.7731.8399.0
+86.21.37820625
│
salesusa@standexmeder.com
│ info@standexmeder.com
│ salesasia@standexmeder.com
Version 01
27.01.2015
Modifications in the sense of technical progress are reserved.
A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
Series Datasheet – MK02 Reed Sensors
Housing and Cable Specifications
Housing Material
Case Color
Sealing Compound
Cable Typ
Cable Material
Cross Section (mm²)
PBT Glass Fibre Reinforced
Blue
Polyurethan
Round Cable
PVC
4 x 0.14 / 2 x 0.25
www.standexmeder.com
MK02 Reed Sensor
Environmental Data
Shock Resistance (max.)
1/2 sine wave duration 11ms
Unit
50
20
-5 to 80
-30 to 80
-30 to 80
g
g
°C
°C
°C
Vibration Resistance (max.)
Operating Temperature
Cable not moved
Handing & Assembly Instructions
Max torque of screw is 1Nm
Cable bending-radius is diameter x 15
Min. bending distance to housing is 5mm
Drag mark out of the mounting area forbidden
Decrease switching distance by mounting on iron
Do not use magnetically inductive screws
Series resistor recommended for > 5m cable length
Operating Temperature
Cable moved
Storage Temperature
Glossary Contact Form
Form A
Form B
Form C
NO = Normally Open Contacts
SPST = Single Pole Single Throw
NC = Normally Closed Contacts
SPST = Single Pole Single Throw
Changeover
SPDT = Single Pole Double Throw
Life Test Data
*Load increase reduces life expectancy of Reed Switches
USA:
Europe:
Asia:
+1.866.782.6339
+49.7731.8399.0
+86.21.37820625
│
salesusa@standexmeder.com
│ info@standexmeder.com
│ salesasia@standexmeder.com
Version 01
27.01.2015
Modifications in the sense of technical progress are reserved.
A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
Series Datasheet – MK02 Reed Sensors
Operation Series – Screw Flange Mount
www.standexmeder.com
For best operation it is recommended that you DO NOT mount these sensors on any ferromagnetic material OR use any
ferromagnetic screws.
* Dimension (mm): 3 x 12 x 32
The standard cable is a 4-wire round - core 4 x 0.14 mm2 (cable sheath and wires are white) forming a sabotage loop. See example
of this loop to the right.
Sabotage loop for
MK02/2, MK02/3
USA:
Europe:
Asia:
+1.866.782.6339
+49.7731.8399.0
+86.21.37820625
│
salesusa@standexmeder.com
│ info@standexmeder.com
│ salesasia@standexmeder.com
Version 01
27.01.2015