10Gbit/s XFP Transceiver 1550nm 80km
TDM & DWDM C-Band 100GHz Spacing Application
(TRX10GEA3x01/Cxx)
Product Brief
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
Fully compliant to XFP MSA Rev. 4.5
Multi-Rates for SONET/SDH and Ethernet Applications
Supports 9.95Gb/s to 11.3Gbit/s transmission and FEC
functionality
Transmission distance up to 80km over single mode
fiber
TDM or DWDM with 100GHz spacing
Low power consumption below 3.5W (Max)
Wide operating temperature range: 0°C to +70°C
Laser Class 1 compliant
Electro-absorption Modulated Laser (EML)
LC duplex connector
Hot pluggable 30pin connector
XFI electrical interface, AC-coupled
Compliant with the EU RoHS 6 environmental requirements
General Description and Applications
The TRX10GEA3x01/Cxx is a multi-purpose serial optical transceiver family for 10Gbit/s data
transmission applications. The standard compliant
Nominal
transceiver is ideally suited for Datacom and
Standard
Description
Baud
Unit
Rate
SONET/SDH applications. Designed for extended
reach the transceiver module comprises a
SDH
ITU-T G.691
9.95
GBd
transmitter with an Electro-absorption Modulated
ITU G.709 (OUT-2)
Laser (EML) and a receiver with APD photodiode.
SDH
10.71
GBd
OC-192 with FEC
The transceiver operates within a wide
SONET
GR-253-Core
9.95
GBd
temperature range of 0°C to +70°C and offers
optimum heat dissipation. The transceiver also
Ethernet 80km
10GBASE-ZR
10.31
GBd
provides excellent electromagnetic shielding
thus enabling high port densities for 10Gbit/s systems. A 30 pin electrical connector and a duplex LC
connector optical interface to assure the MSA compliant connectivity of the solid metal XFP package.
TRX10GEA3x01Cxx, Date: 24.07.2009
SP/4100-16:74-02 Rev A02
1/2
Copyright © 2009 MergeOptics GmbH, MergeOptics GmbH reserves the right to make changes in design, specifications and other information at any time
without prior notice. Information in this data sheet is believed to be reliable. However, no responsibility is assumed for possible inaccuracy or omission.
Ordering Information
TRX10GEA
3x
01
Cxx
Standard
31
34
36
Ethernet 80km, 10GBase-ZR
SONET OC-192 / SDH STM-64 LR-2
10GBase-ZR / SONET OC-192
Package
01
XFP with CDR
Transmitted Wavelength
Cxx
TDM transceiver, Center Wavelength 1550nm
Part number extension for DWDM product.
List of extensions specified in table below for
C-band coverage.
Center Wavelength Table Against Part Number Extension for DWDM XFP
Extension
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
GHz
190100
190200
190300
190400
190500
190600
190700
190800
190900
191000
191100
191200
191300
191400
191500
191600
191700
191800
nm
1577,03
1576,20
1575,37
1574,54
1573,71
1572,89
1572,06
1571,24
1570,42
1569,59
1568,77
1567,95
1567,13
1566,31
1565,50
1564,68
1563,86
1563,05
Extension
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
GHz
191900
192000
192100
192200
192300
192400
192500
192600
192700
192800
192900
193000
193100
193200
193300
193400
193500
193600
nm
1562,23
1561,42
1560,61
1559,79
1558,98
1558,17
1557,36
1556,55
1555,75
1554,94
1554,13
1553,33
1552,52
1551,72
1550,92
1550,12
1549,32
1548,51
Extension
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
GHz
193700
193800
193900
194000
194100
194200
194300
194400
194500
194600
194700
194800
194900
195000
195100
195200
195300
195400
nm
1547,72
1546,92
1546,12
1545,32
1544,53
1543,73
1542,94
1542,14
1541,35
1540,56
1539,77
1538,98
1538,19
1537,40
1536,61
1535,82
1535,04
1534,25
Extension
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
GHz
195500
195600
195700
195800
195900
196000
196100
196200
196300
196400
196500
196600
196700
196800
196900
197000
197100
197200
nm
1533,47
1532,68
1531,90
1531,12
1530,33
1529,55
1528,77
1527,99
1527,22
1526,44
1525,66
1524,89
1524,11
1523,34
1522,56
1521,79
1521,02
1520,25
For more technical information, please email us at
info@mergeoptics.com.
TRX10GEA3x01Cxx, Date: 24.07.2009
SP/4100-16:74-02 Rev A02
Copyright © 2009 MergeOptics GmbH, MergeOptics GmbH reserves the right to make changes in design, specifications and other information
at any time without prior notice. Information in this data sheet is believed to be reliable. However, no responsibility is assumed for possible
inaccuracy or omission.
2/2