TL8018-5
R
C
US
Conforms to EN1088, EN60947-5-1, EN292, EN60204-1
UL and C-UL listed
G
safety interlock switches
TL8018-5
■
■
Heavy-Duty Safety Interlock Switch with Guard Door Locking
High locking force of 5,500 N
(1,236 lb.)—locks guard door
shut until machine is safe to
enter
Rugged enclosure—the die-cast
housing and stainless steel
actuator of the TL8018-5 make it
suitable for harsh environments
NEMA 4 enclosure enables the
TL8018-5 to withstand water
washdown cleaning
■
Lid-mounted status light is on
when solenoid is energized,
indicating that solenoid has
unlocked the guard door
Misalignment tolerant—the self-
aligning head on the TL8018-5
enables it to operate with con-
siderable actuator misalignment
Optional trapped key—the key
must be trapped in the lock to
enable machine operation. The
key must be rotated in order to
unlock the guard door.
■
Long life—the TL8018-5, with
its stainless steel actuator, is
designed for a minimum of one
million actuations.
■
■
■
A
N
Go to the Engineering Guide
For in-depth information on
safety standards and use.
For More Guarding Products
See Section N for safeguarding
cutting and turning machines
OmrOn Scientific technOlOgieS, inc.
USA
Tel. 1/888/510-4357
canada
Tel. 1/866/986-6766
G212
For the Latest Information
On the Internet:
www.sti.com
or
www.omron.ca
TL8018-5
■
Operation
Contact Arrangements
A1 A2 AC/DC
100% ED.
5
7
1
6
8
4
2
3
Actuator insertion
Solenoid de-energized
20
5/6
7/8
1/2
3/4
19
12
0mm
The patented floating head allows movement
horizontally of the cam housing which tolerates
actuator or guard misalignment.
13.5
contact Open
contact closed
Optional Trapped Key Version
1. Signal to TL8018-5 indicating
machine is in a safe condition
and energizes the solenoid.
G
safety interlock switches
LH key version
Locking Force = 5,500 N (1,236 lb.) maximum.
A distance of 8 mm or less between face of
switch and face of actuator is required for switch
to lock.
2. Key rotated to open
position, which locks open
the TL8018. Guard cannot
lock and machine cannot start
up with key switch in open
position.
3. Guard can be opened only
after key is rotated
to open position.
4. Key can be used as a personnel key.
Key may be removed only when key
switch is in open position.
OmrOn Scientific technOlOgieS, inc.
USA
Tel. 1/888/510-4357
canada
Tel. 1/866/986-6766
For the Latest Information
On the Internet:
www.sti.com
or
www.omron.ca
G213
TL8018-5
■
Applications
Typical applications are on
sliding guard doors and swinging
guard doors that must remain
locked until a signal is applied to
the internal solenoid that unlocks
the guard door.
Typical Application of TL8018-5 with a SR103AM and SR125SMS
circuit operating principle
fault detection,
✎
For a full explanation of the in the Engineering Sectionandthis catalog. see
“Common Circuit Examples”
of
24VAC/DC, 110VAC, 230VAC
(AUX)
G
safety interlock switches
K1
FUSE
L1 L2 L3
MOMENTARY
PUSH BUTTON
START
(AUX)
K2
(AUX)
MOMENTARY
PUSH BUTTON
STOP
MOMENTARY
PUSH BUTTON
RESET
K1(a)
(AUX)
K1
K2
(AUX)
K2(a)
(AUX)
FUSE
LOCK RELEASE
MOMENTARY
PUSH BUTTON
A1
Power supply
(S11 = 24 V)
K2
+
S11
S21
S12
S14
13
23
33
41
GUARD
CLOSED
TL8018-5
1
3
Relay control and
fault monitoring
+
m
A1
Z1
Z2
Z3
K1
13
21
Logic
1
14
24
34
42
CONTACT
PROTECTION
E.G.
THERMAL
CUT OUT
+24V
2
9
10 21
7
Sr103Am
A2
S10 S13
K1
Y33/43
4
22
8
Logic
2
A2
K2
A1/A2
Zero
Speed
Y34
Y44
14
22
EB Series
LATCHING
E-STOP
BUTTON
FUSES
K1
K2
Sr125SmS
to PLC
INDICATION BULB
Shows Stopped Motion
A
N
OmrOn Scientific technOlOgieS, inc.
USA
Tel. 1/888/510-4357
canada
Tel. 1/866/986-6766
G214
For the Latest Information
On the Internet:
www.sti.com
or
www.omron.ca
Go to the Engineering Guide
For in-depth information on
safety standards and use.
For More Guarding Products
See Section N for safeguarding
cutting and turning machines
TL8018-5
Typical Application of TL8018-5 with E-Stop in a Dual Channel Delayed Output Configuration
24VAC/DC, 110VAC, 230VAC
(AUX)
K1
MOMENTARY
PUSH BUTTON
START
(AUX)
K2
STOP
MOMENTARY
PUSH BUTTON
STOP
MOMENTARY
AUX. CONTACTS
L1 L2 L3
Reset
FUSE
GUARD
CLOSED
1
3
A1 S52 S11 S12 S21 S22
S33 S34 13
23
37
47
55
TL8018-5
Sr209AD
(S34-Y1) External
Jumper
A1
4
22
8
G
K1
Y1
14
24
38
48
56
safety interlock switches
2
9
10 21
7
X1
X2
X3
X4 Y39 Y40 Y2
K2
CONTACT
PROTECTION
E.G. THERMAL
CUT OUT
EB Series
LATCHING
E-STOP
BUTTON
Timer
Override
LOCK RELEASE
MOMENTARY
PUSH BUTTON
FUSES
K1
K2
D1
D1, D2 = Delayed
Output Load
Indicator
m
Ground
MUST PERFORM RESET BEFORE MOTOR MAY BE STARTED
■
Application Monitoring Units
SR223SMT Timer Unit
Used with machines with constant overrun. Gives
a timed delay to the lock/release signal. Failsafe
and adjustable to a range of times from 1.0
seconds up to 31 seconds.
SR125SMS Stop Motion
Sensing Unit
Used with the TL8018-5 for machines with
inconstant or variable overrun. Senses back EMF
of AC or DC motors. Failsafe and adjustable to a
range of 0.01 V to 0.10 V.
Safety Monitoring Relay Units
Safety monitoring relays ensure a maximum level
of safety by monitoring all wiring in the safety
circuit, including switches and contactors. Any
fault and the power to the machine is switched
off. A variety of safety monitoring relay units are
available.
✎
For information on the SR223SMT,
see page H82
✎
For information on the SR125SMS,
see page H42
For the Latest Information
✎
For information on Safety Monitoring
Relays, see page H1
OmrOn Scientific technOlOgieS, inc.
USA
Tel. 1/888/510-4357
canada
Tel. 1/866/986-6766
On the Internet:
www.sti.com
or
www.omron.ca
G215
TL8018-5
■
Specifications
tl8018-5 w/ Key left
2 N/C + 1 N/O
2 N/C positive break
500 V–1 A, 250 V–2 A, 100 V–5 A
250 V–0.5 A, 24 V–2 A
> 2 mm (0.079 in.)
1 N/O
500 V/500 VA
5 V 5 mA DC
1 x 10
6
minimum
24 VAC/DC or 110 VAC or 220 VAC
13 W, approx. 1.6 A inrush
100% duty
Any position
4 x M5 screws
8 mm (0.315 in.)
Apprx. 300 mm (11.8 in.) end entry;
approx. 800 mm (31.5 in.) front entry
max holding force:
max Actuation Speed:
max Activation frequency:
case material:
Actuator material:
Wiring entry:
Weight:
color:
mechanical life:
5,500 N (1,236 lb.)
160 mm/sec (6.3 in./sec)
2 cycles/sec
Die-cast alloy
Stainless steel
3 x 0.5 in. NPT conduit
1,200 g (2.6 lb.)
Red
1 x 10
6
minimum
IP65 (NEMA 4)
-10 to 60°C (14 to 140°F)
Water washdown
EN1088, EN60947-5-1, EN292, EN60204-1
CE marked for all applicable directives, UL and C-UL
All models
electrical
contact configurations:
Safety contacts:
Switching Ability
Ac:
Dc:
Safety contact gap:
Auxiliary contacts:
max Switching current/Volt/Amp:
minimum current:
electrical life:
Solenoid Supply Voltage:
Solenoid Power:
Solenoid rating:
mechanical
mounting:
mounting hardware:
Actuator travel for Positive Opening:
min Operating radius:
G
safety interlock switches
environmental
Protection:
Operating temperature:
cleaning:
compliance
Standards:
Approvals/listings:
Specifications are subject to change without notice.
Note: The safety contacts of the Omron STI switches are described as normally closed (N/C)—i.e., with the guard closed, actuator in place, and the
machine able to be started.
A
N
OmrOn Scientific technOlOgieS, inc.
USA
Tel. 1/888/510-4357
canada
Tel. 1/866/986-6766
G216
For the Latest Information
On the Internet:
www.sti.com
or
www.omron.ca
Go to the Engineering Guide
For in-depth information on
safety standards and use.
For More Guarding Products
See Section N for safeguarding
cutting and turning machines