https://www.phoenixcontact.com/hq/products/2982537
Solid-state relay module - PLC-OSP- 48DC/110DC/ 3RW - 2982537
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
PLC-INTERFACE for railway applications, consisting of basic terminal block with spring-cage connection and
integrated miniature solid-state relay, range: 0.7 x U
N
to 1.25 x U
N
, temperature range: -25°C to +70°C, 1 N/O
contact, input: 48 V DC, output: 12 - 140 V DC/3 A
The illustration shows the 24 V
version.
Why buy this product
Shock resistance according to DIN 50155 (requirements according to EN 61373)
Temperature range of -25°C to +70°C
Input voltage range of 0.7 - 1.25 x UN
Key Commercial Data
Packing unit
GTIN
GTIN
Custom tariff number
4046356082594
85364190
10 STK
Technical data
Note
Utilization restriction
EMC: class A product, see manufacturer's declaration in the download
area
Dimensions
Width
Height
Depth
6.2 mm
80 mm
86 mm
Ambient conditions
Ambient temperature (operation)
Ambient temperature (storage/transport)
Degree of protection
-25 °C ... 70 °C
-40 °C ... 85 °C
IP20
11/15/2016 Page 1 / 4
https://www.phoenixcontact.com/hq/products/2982537
Solid-state relay module - PLC-OSP- 48DC/110DC/ 3RW - 2982537
Technical data
Input data
Nominal input voltage U
N
Input voltage range in reference to U
N
Input voltage range
Switching threshold "0" signal in reference to U
N
Switching threshold "1" signal in reference to U
N
Typical input current at U
N
Typical response time
Typical turn-off time
Operating voltage display
Type of protection
Protective circuit/component
Surge voltage protection
Transmission frequency
48 V DC
0.7 ... 1.25 (t < 1 s = 0.6 ... 1.4 x U
N
)
33.6 V DC ... 60 V DC
< 0.3
> 0.6
5.5 mA
40 µs
200 µs
Yellow LED
Reverse polarity protection
Surge protection
Series polarity protection diode
> 150 V
300 Hz
Output data
Output nominal voltage
Output voltage range
Limiting continuous current
Surge voltage protection
Voltage drop at max. limiting continuous current
Output circuit
Type of protection
Protective circuit/component
110 V DC
12 V DC ... 140 V DC (t < 1 s = 1.40 x U
N
)
3 A (see derating curve)
> 150 V
< 150 mV
2-wire, floating
Reverse polarity protection
Surge protection
Parallel polarity protection diode
Connection data, input side
Connection name
Connection method
Stripping length
Conductor cross section solid
Conductor cross section flexible
Conductor cross section AWG
Input side
Spring-cage connection
8 mm
0.14 mm² ... 2.5 mm²
0.14 mm² ... 2.5 mm²
26 ... 14
Connection data, output side
Connection name
Connection method
Stripping length
Conductor cross section solid
Conductor cross section flexible
Conductor cross section AWG
Output side
Spring-cage connection
8 mm
0.14 mm² ... 2.5 mm²
0.14 mm² ... 2.5 mm²
26 ... 14
General
11/15/2016 Page 2 / 4
https://www.phoenixcontact.com/hq/products/2982537
Solid-state relay module - PLC-OSP- 48DC/110DC/ 3RW - 2982537
Technical data
General
Test voltage input/output
Mounting position
Assembly instructions
Operating mode
Designation
Standards/regulations
2.5 kV
rms
any
In rows with zero spacing
100% operating factor
Air clearances and creepage distances between the power circuits
IEC 60664
EN 50178
IEC 62103
Rated surge voltage/insulation
Rated insulation voltage
Degree of pollution
Overvoltage category
4 kV / basic insulation
160 V DC
2
III
Standards and Regulations
Connection in acc. with standard
Designation
Standards/regulations
CUL
Air clearances and creepage distances between the power circuits
IEC 60664
EN 50178
IEC 62103
Rated insulation voltage
Rated surge voltage/insulation
Degree of pollution
Overvoltage category
160 V DC
4 kV / basic insulation
2
III
Environmental Product Compliance
China RoHS
Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”,
Category “Manufacturer's declaration”
Drawings
Diagram
Load current [A]
3,5
3
2,5
2
1,5
1
0,5
0
20
35
40
50
60
70
Ambient temperature [°C]
A1
Circuit diagram
14
14
A2
13+
A2
13+
Approvals
Approvals
11/15/2016 Page 3 / 4
https://www.phoenixcontact.com/hq/products/2982537
Solid-state relay module - PLC-OSP- 48DC/110DC/ 3RW - 2982537
Approvals
Approvals
UL Listed / cUL Listed / GL / UL Recognized / cUL Recognized / EAC / PRS / cULus Recognized / cULus Listed
Ex Approvals
Approval details
UL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 172140
cUL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 172140
GL http://www.gl-group.com/newbuilding/approvals/index.html 46016-03 HH
UL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705
cUL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705
EAC 7500651.22.01.00244
PRS http://www.prs.pl/ TE/2109/880590/16
cULus Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
cULus Listed
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
11/15/2016 Page 4 / 4