https://www.phoenixcontact.com/hq/products/3062951
Connection terminal block - AKG 16 RD - 3062951
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Connection terminal block, Connection method Screw connection, Load current : 76 A, Cross section: 1.5
mm² - 16 mm², Width: 9.8 mm, Color: red
The figure shows a version of the
article
Key Commercial Data
Packing unit
GTIN
GTIN
Custom tariff number
Note
4046356558365
85369010
Made to Order (non-returnable)
50 STK
Technical data
General
Color
Insulating material
Nominal cross section
Flammability rating according to UL 94
Maximum load current
Nominal current I
N
Maximum load current
Nominal voltage U
N
red
PA
16 mm²
V2
76 A (with 16 mm² conductor cross section)
76 A
76 A (with 16 mm² conductor cross section)
300 V
Dimensions
Length
Width
23.7 mm
9.8 mm
Connection data
Conductor cross section solid min.
1.5 mm²
11/15/2016 Page 1 / 3
https://www.phoenixcontact.com/hq/products/3062951
Connection terminal block - AKG 16 RD - 3062951
Technical data
Connection data
Conductor cross section solid max.
Conductor cross section flexible min.
Conductor cross section flexible max.
Conductor cross section AWG min.
Conductor cross section AWG max.
Conductor cross section flexible, with ferrule without plastic sleeve min.
Conductor cross section flexible, with ferrule with plastic sleeve min.
Conductor cross section flexible, with ferrule with plastic sleeve max.
2 conductors with same cross section, solid min.
2 conductors with same cross section, solid max.
2 conductors with same cross section, stranded min.
2 conductors with same cross section, stranded max.
2 conductors with same cross section, stranded, ferrules without plastic
sleeve, min.
2 conductors with same cross section, stranded, ferrules without plastic
sleeve, max.
2 conductors with same cross section, stranded, TWIN ferrules with
plastic sleeve, min.
2 conductors with same cross section, stranded, TWIN ferrules with
plastic sleeve, max.
Connection method
Stripping length
Screw thread
Tightening torque, min
Tightening torque max
16 mm²
1.5 mm²
16 mm²
16
6
1.5 mm²
1.5 mm²
16 mm²
1.5 mm²
6 mm²
1.5 mm²
6 mm²
1.5 mm²
6 mm²
1.5 mm²
10 mm²
Screw connection
16 mm
M5
2.5 Nm
3 Nm
Conductor cross section flexible, with ferrule without plastic sleeve max. 16 mm²
Standards and Regulations
Connection in acc. with standard
Flammability rating according to UL 94
CSA
V2
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Approvals
Approvals
Approvals
CSA / UL Recognized / cUL Recognized / EAC / cULus Recognized
11/15/2016 Page 2 / 3
https://www.phoenixcontact.com/hq/products/3062951
Connection terminal block - AKG 16 RD - 3062951
Approvals
Ex Approvals
Approval details
CSA
http://www.csagroup.org/services/testing-and-certification/certified-product-listing/ 13631
18-6
65 A
mm²/AWG/kcmil
Nominal current IN
UL Recognized
mm²/AWG/kcmil
Nominal current IN
Nominal voltage UN
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 60425
B
18-6
50 A
250 V
C
18-6
50 A
300 V
cUL Recognized
mm²/AWG/kcmil
Nominal current IN
Nominal voltage UN
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 60425
B
18-6
50 A
250 V
C
18-6
50 A
300 V
EAC EAC-Zulassung
cULus Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm