Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
6307FE Multi-Conductor - Commercial Applications
For more Information
please call
1-800-Belden1
General Description:
Security & Alarm Cable, Plenum-CMP, 9-18 AWG stranded bare copper conductors with Flamarrest®
insulation, Beldfoil® shield and Flamarrest® jacket with ripcord
Usage (Overall)
Suitable Applications:
Security Systems, Intercom/PA Systems, Sound/Audio Systems, Power Limited Controls
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors AWG Stranding Conductor Material
9
18
7x26
BC - Bare Copper
9
Total Number of Conductors:
Insulation
Insulation Material:
Insulation Trade Name Insulation Material
Flamarrest®
Wall Thickness (in.)
LS PVC - Low Smoke Polyvinyl Chloride 0.009
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material
Beldfoil®
Coverage (%)
Tape Aluminum Foil-Polyester Tape 100
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
24
(7x32)
TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Trade Name Outer Jacket Material
Flamarrest®
Outer Jacket Ripcord:
Nom. Wall Thickness (in.)
LS PVC - Low Smoke Polyvinyl Chloride .015
Yes
Overall Cable
Overall Cabling Color Code Chart:
Number Color
1
2
3
4
5
6
7
8
9
Black
Red
White
Green
Brown
Blue
Orange
Yellow
Purple
0.266 in.
Overall Nominal Diameter:
Mechanical Characteristics (Overall)
Operating Temperature Range:
UL Temperature Rating:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius/Minor Axis:
0°C To +75°C
75°C
67 lbs/1000 ft.
215.600 lbs.
2.750 in.
Page 1 of 3
09-11-2017
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
6307FE Multi-Conductor - Commercial Applications
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
NEC Articles:
CEC/C(UL) Specification:
EU Directive 2011/65/EU (ROHS II):
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
CMP
800
CMP
Yes
Yes
Yes
Yes
04/01/2005
Yes
Yes
Yes
Yes
Flame Test
UL Flame Test:
C(UL) Flame Test:
NFPA 262
FT6
Plenum/Non-Plenum
Plenum (Y/N):
Non-Plenum Number:
Yes
5307FE
Electrical Characteristics (Overall)
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/ft)
42
Nom. Capacitance Cond. to Other Conductor & Shield:
Capacitance (pF/ft)
76
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
6.5
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
13.800
Max. Operating Voltage - UL:
Voltage
300 V RMS
Max. Recommended Current:
Current
3.5 Amps per conductor @ 25°C
Put Ups and Colors:
Item #
6307FE 8771000
6307FE 877500
Notes:
C = CRATE REEL PUT-UP.
Putup
1,000 FT
500 FT
Ship Weight
72.000 LB
36.000 LB
Color
NATURAL
NATURAL
Notes
C
Item Desc
9 #18 FLRST FS FLRST
TRANSFER REVIEW (20 TO 30)
Revision Number: 2
© 2017 Belden, Inc
All Rights Reserved.
Revision Date: 01-19-2015
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities
and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is
correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the
safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification.
Page 2 of 3