https://www.phoenixcontact.com/pi/products/3000692
COMBI receptacle - PPC 6/1-L GNYE - 3000692
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
COMBI receptacle, nom. voltage: 1000 V, nominal current: 41 A, connection method: Push-in / plug
connection, number of connections: 2, number of positions: 1, cross section:0.5 mm² - 10 mm², AWG: 20 - 8,
width: 8.2 mm, height: 24.7 mm, color: green/yellow
Your advantages
For secure and space-saving accommodation of plug-in contacts in cable ducts and distributor shafts
The Push-in technology COMBI couplings for self-assembly provide solutions that users can implement themselves
Tested for railway applications
Key Commercial Data
Packing unit
GTIN
GTIN
4046356751810
50 pc
Technical data
General
Number of positions
Number of levels
Number of connections
Potentials
Nominal cross section
Color
Insulating material
Flammability rating according to UL 94
Area of application
1
1
2
1
6 mm²
green/yellow
PA
V0
Railway industry
Machine building
Plant engineering
Maximum load current
Rated surge voltage
41 A (with 6 mm² conductor cross section)
8 kV
11/29/2018 Page 1 / 5
https://www.phoenixcontact.com/pi/products/3000692
COMBI receptacle - PPC 6/1-L GNYE - 3000692
Technical data
General
Degree of pollution
Overvoltage category
Insulating material group
Maximum power dissipation for nominal condition
Maximum load current
Nominal current I
N
Nominal voltage U
N
Open side panel
Relative insulation material temperature index (Elec., UL 746 B)
Temperature index of insulation material (DIN EN 60216-1 (VDE
0304-21))
Static insulating material application in cold
Behavior in fire for rail vehicles (DIN 5510-2)
Flame test method (DIN EN 60695-11-10)
Oxygen index (DIN EN ISO 4589-2)
NF F16-101, NF F10-102 Class I
NF F16-101, NF F10-102 Class F
Surface flammability NFPA 130 (ASTM E 162)
Specific optical density of smoke NFPA 130 (ASTM E 662)
Smoke gas toxicity NFPA 130 (SMP 800C)
Calorimetric heat release NFPA 130 (ASTM E 1354)
Fire protection for rail vehicles (DIN EN 45545-2) R22
Fire protection for rail vehicles (DIN EN 45545-2) R23
Fire protection for rail vehicles (DIN EN 45545-2) R24
Fire protection for rail vehicles (DIN EN 45545-2) R26
3
III
I
1.31 W
41 A (with 6 mm² conductor cross section)
41 A
1000 V
Yes
130 °C
125 °C
-60 °C
Test passed
V0
>32 %
2
2
passed
passed
passed
27,5 MJ/kg
HL 1 - HL 3
HL 1 - HL 3
HL 1 - HL 3
HL 1 - HL 3
Dimensions
Width
End cover width
Length
Height
Pitch
8.2 mm
2.2 mm
47 mm
24.7 mm
8.2 mm
Connection data
Connection method
Connection in acc. with standard
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section AWG min.
Conductor cross section AWG max.
Conductor cross section flexible min.
Conductor cross section flexible max.
Push-in / plug connection
IEC 61984
0.5 mm²
10 mm²
20
8
0.5 mm²
6 mm²
11/29/2018 Page 2 / 5
https://www.phoenixcontact.com/pi/products/3000692
COMBI receptacle - PPC 6/1-L GNYE - 3000692
Technical data
Connection data
Min. AWG conductor cross section, flexible
Max. AWG conductor cross section, flexible
Conductor cross section flexible, with ferrule without plastic sleeve min.
Conductor cross section flexible, with ferrule with plastic sleeve min.
Conductor cross section flexible, with ferrule with plastic sleeve max.
2 conductors with same cross section, stranded, TWIN ferrules with
plastic sleeve, min.
2 conductors with same cross section, stranded, TWIN ferrules with
plastic sleeve, max.
Stripping length
Internal cylindrical gage
20
10
0.5 mm²
0.5 mm²
6 mm²
0.5 mm²
1.5 mm²
12 mm
A5
Conductor cross section flexible, with ferrule without plastic sleeve max. 6 mm²
Standards and Regulations
Connection in acc. with standard
Flammability rating according to UL 94
Fire protection for rail vehicles (DIN EN 45545-2) R22
Fire protection for rail vehicles (DIN EN 45545-2) R23
Fire protection for rail vehicles (DIN EN 45545-2) R24
Fire protection for rail vehicles (DIN EN 45545-2) R26
IEC 61984
V0
HL 1 - HL 3
HL 1 - HL 3
HL 1 - HL 3
HL 1 - HL 3
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Drawings
Circuit diagram
45
40
35
30
25
20
15
10
5
0
0
Diagram
Current strength [A]
= 2-pos.
= 5-pos.
= 10-pos.
20
40
60
80
100
Ambient temperature [°C]
Approvals
Approvals
Approvals
DNV GL / CSA / BV / LR / UL Recognized / cUL Recognized / IECEE CB Scheme / VDE Gutachten mit Fertigungsüberwachung / cULus
Recognized
11/29/2018 Page 3 / 5
https://www.phoenixcontact.com/pi/products/3000692
COMBI receptacle - PPC 6/1-L GNYE - 3000692
Approvals
Ex Approvals
Approval details
DNV GL
http://exchange.dnv.com/tari/
TAE000015D
CSA
Nominal voltage UN
Nominal current IN
mm²/AWG/kcmil
B
600 V
36 A
20-8
http://www.csagroup.org/services-industries/product-listing/
C
600 V
36 A
20-8
13631
BV
B
600 V
40 A
20-8
http://www.veristar.com/portal/veristarinfo/generalinfo/
approved/approvedProducts/equipmentAndMaterials
45602/A0
LR
http://www.lr.org/en
16/20057
UL Recognized
Nominal voltage UN
Nominal current IN
mm²/AWG/kcmil
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
C
600 V
40 A
20-8
FILE E 60425
cUL Recognized
Nominal voltage UN
Nominal current IN
mm²/AWG/kcmil
B
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
C
600 V
40 A
20-8
FILE E 60425
600 V
40 A
20-8
11/29/2018 Page 4 / 5
https://www.phoenixcontact.com/pi/products/3000692
COMBI receptacle - PPC 6/1-L GNYE - 3000692
Approvals
IECEE CB Scheme
Nominal voltage UN
http://www.iecee.org/
DE1-56601/B1
1000 V
VDE Gutachten mit
Fertigungsüberwachung
Nominal voltage UN
http://www2.vde.com/de/Institut/Online-Service/
VDE-gepruefteProdukte/Seiten/Online-Suche.aspx
1000 V
40043445
cULus Recognized
Phoenix Contact 2018 © - all rights reserved
http://www.phoenixcontact.com
PHOENIX CONTACT GmbH & Co. KG
Flachsmarktstr. 8
32825 Blomberg
Germany
Tel. +49 5235 300
Fax +49 5235 3 41200
http://www.phoenixcontact.com