For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642,
or visit Maxim’s website at www.maxim-ic.com.
On/Off Controller with Debounce and
±15kV ESD Protection
MAX16054
ABSOLUTE MAXIMUM RATINGS
V
CC
to GND ..............................................................-0.3V to +6V
IN to GND ................................................................-30V to +30V
CLEAR to GND .........................................................-0.3V to +6V
OUT,
OUT
to GND......................................-0.3V to (V
CC
+ 0.3V)
Short-Circuit Duration
OUT,
OUT
to GND ...................................................Continuous
Note 1:
As per JEDEC 51 standard, multilayer board (PCB).
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
Continuous Power Dissipation (T
A
= +70°C)
6-Pin Thin SOT23
(derate 9.1mW/°C at +70°C) (Note 1) ............................727mW
Operating Temperature Range .........................-40°C to +125°C
Maximum Junction Temperature .....................................+150°C
Storage Temperature Range .............................-60°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
ELECTRICAL CHARACTERISTICS
(V
CC
= +2.7V to +5.5V, T
A
= T
J
= -40°C to +125°C, unless otherwise noted. Typical values are at V
CC
= +5V, T
A
= +25°C.) (Note 2)
PARAMETER
Operating Voltage Range
Supply Current
Debounce Duration
SYMBOL
V
CC
I
CC
t
DP
V
IL
IN Threshold
IN Hysteresis
IN Pullup Resistance
IN Current
IN Voltage Range
Undervoltage-Lockout Threshold
OUT/OUT Output Voltage
I
IN
V
IN
V
UVLO
V
OL
V
OH
V
CLEAR_IL
CLEAR Threshold
CLEAR Input Current
CLEAR High to OUT Low
Propagation Delay
ESD CHARACTERISTICS
IEC 61000-4-2 Air
Discharge
ESD Protection
IN
IEC 61000-4-2 Contact
Discharge
Human Body Model
±15
±8
±15
kV
V
CLEAR_IH
I
CLEAR
t
CO
R
L
= 10kΩ, C
L
= 100pF
V
CC
= 5V
V
CC
= 2.7V
2.4
2.0
-1
+1
200
µA
ns
V
CC
falling
I
SINK
= 1.6mA
I
SOURCE
= 0.4mA
V
CC
- 1.0
0.7
V
V
IN
= +25V
V
IN
= -25V
-1.5
-25
1.8
+25
2.4
0.4
32
V
IH
V
CC
= 5V
V
CC
= 2.7V
2.5
2.0
420
63
100
+1.5
mV
kΩ
mA
V
V
V
(Note 3)
V
CC
= 5V, I
OUT
= I
OUT
= 0,
IN not connected
T
A
= +25°C
T
A
= -40°C to +125°C
20
5
CONDITIONS
MIN
2.7
7
50
50
TYP
MAX
5.5
20
80
99
0.65
V
UNITS
V
µA
ms
Note 2:
All devices are 100% production tested at T
A
= +25°C. Specifications over temperature limits are guaranteed by design.