电子工程世界电子工程世界电子工程世界

关键词

搜索

型号

搜索

TR-11SX6322A

产品描述Circuit Breakers CIRCUIT BREAKER FOR EQUIPMENT,
产品类别电路保护   
文件大小3MB,共6页
制造商Altech
官网地址http://www.altechcorp.com/
下载文档 详细参数 全文预览

TR-11SX6322A在线购买

供应商 器件名称 价格 最低购买 库存  
TR-11SX6322A - - 点击查看 点击购买

TR-11SX6322A概述

Circuit Breakers CIRCUIT BREAKER FOR EQUIPMENT,

TR-11SX6322A规格参数

参数名称属性值
Product AttributeAttribute Value
制造商
Manufacturer
Altech
产品种类
Product Category
Circuit Breakers
产品
Product
Circuit Breakers
类型
Type
Supplementary Protector
NumOfPackaging1

文档预览

下载PDF文档
UL 489
UL 508
TR11 Series
UL1077 Recognized
Supplementary Protector/
Circuit Breaker for Equipment
Applications:
Protection of Control Transformers, UPS, Power
strips, Solenoids etc., against damage due to
overload conditions.
Current Rating (A)
Standard Current Rating (A)
0.1 - 16A
0.1, 0.25, 0.5, 0.9, 1.0, 1.2, 1.5, 1.8, 2.0, 2.2, 2.5,
2.7, 3.0, 3.3, 4.0, 5.0, 6.0, 6.5, 7.0, 8.0, 9.0,
10.0, 12.0, 15.0, 16.0
240V AC, 50/60Hz,
50V DC / 24V DC (VDE)
> 100 M ohms.
(As per EN 60934)
E209569
up to 12 Amps
Operating Characteristic
(min) 60
30
20
10
5
1
(S) 50
20
10
5
2
1
Trip time
0.5
0.2
0.1
1.05 1.32
2
3
4 5
8 10
Rated Voltage
Initial insulation resistance (500V DC)
Dielectric strength
1.5 KV for One minute.
(As per EN 60934)
6 I
n
- AC up to 9.0A
(As per EN 60934)
4 I
n
- DC up to 12.0A
60A AC/DC Max. - from 10.0A to 12.0A
8x I
n
AC/DC for <6.0A
60A AC/DC MAX. for > 6.0A
1 - 2 Watts
Maximum 60°C Ambient
1000 Cycles
1000 Amps PC 1,240V AC, 24V DC, Ref.: EN60934
SC: 1KA, C1, 240V AC 50V DC
Ref.: CSA22.2 No.235-04, UL-1077
TC 2Ref.: CSA22.2 No. 235-04
OL0 240V AC, 50V DC, Ref.: CSA22.2 No. 235-04
General Industrial Ref.: CSA22.2 No. 235-04
Thermal ‘TO’ Trip Free
Reset Type ‘R’
CSA 22.2 No. 235-04, UL-1077, EN 60934
aprox. 11g
0.1 - 16.0A
240V AC 50V DC
0.5 - 12.0A
240V AC 24V DC
UL 1077
Overload Switching Capacity
Maximum Breaking Capacity
Power Loss
Operating Temperature
Operational Life at 2xI
n
Rated Conditional Short Circuit
Current Capacity I
nc1
(PC1)
Ref.: EN60934
Tripping Current Code TC
Overload Rating
Application Type
Method of Tripping
Type of Actuation
Application Standards
Weight
Approvals
UL 1077
Equipment Breakers
Multiple of Rated Current
Rated current
Ambient
Temperature
ORDERING INSTRUCTIONS
Earth Leakage
Circuit Breakers
PRODUCT
TYPE
CURRENT RATING
0.1 TO 16.0A
MOUNTING NUT
<6A
>6A
23°C
Time Current Characteristics:
The standard characteristic is valid for
ambient temperatures of +23°C. If the
device is to be used in an ambient
temperature other than +23°C,
allowances must be made when selecting
the current rating according to the
following guidelines:
Ambient temp.°C
-20
-5
0
+10 +20 +30 +40 +50 +60
1
1.05 1.12 1.2 1.3
1.8A
40°C
1.12
1.8 x 1.12 = 2.016
2.0A
Correction Factor
Example:
0.8 0.88 0.9 0.96
*
ANNEX
Normal Continuous Current
Ambient Temperature
Correction Factor
Recommended Current Rating
Select the nearest
*
Terminal configuration option X is available up to 12A; special order only. Consult Altech for ordering.
Note: TR11-C Series stocked; contact Altech for availability.
80
Altech Corp.
®
• 35 Royal Road • Flemington, NJ 08822-6000 • P 908.806-9400 • F 908.806.9490 • www.altechcorp.com

技术资料推荐更多

 
EEWorld订阅号

 
EEWorld服务号

 
汽车开发圈

 
机器人开发圈

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程 索引文件: 1080  710  2923  1276  916  30  50  51  28  48 

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区中关村大街18号B座15层1530室 电话:(010)82350740 邮编:100190

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved