https://www.phoenixcontact.com/hq/products/1774153
PCB terminal block - MKDSP 10N/ 3-10,16 BK - 1774153
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
PCB terminal block, Nominal current: 76 A, Nom. voltage: 1000 V, Pitch: 10.16 mm, Number of positions:
3, Connection method: Screw connection with tension sleeve, Mounting: Wave soldering, Conductor/PCB
connection direction: 0 °, Color: black
Key Commercial Data
Packing unit
GTIN
GTIN
Custom tariff number
Note
4046356481601
85369010
Made to Order (non-returnable)
50 STK
Technical data
Dimensions
Length
Pitch
Dimension a
Height
Length of the solder pin
Pin dimensions
Hole diameter
18.4 mm
10.16 mm
20.32 mm
29.3 mm
5 mm
1 x 0,9 mm
1.5 mm
General
Range of articles
Insulating material group
Rated surge voltage (III/3)
Rated surge voltage (III/2)
Rated surge voltage (II/2)
Rated voltage (III/3)
Rated voltage (III/2)
Rated voltage (II/2)
Connection in acc. with standard
Nominal current I
N
Nominal cross section
MKDSP 10N
I
8 kV
8 kV
8 kV
800 V
1000 V
1000 V
EN-VDE
76 A
10 mm²
11/14/2016 Page 1 / 4
https://www.phoenixcontact.com/hq/products/1774153
PCB terminal block - MKDSP 10N/ 3-10,16 BK - 1774153
Technical data
General
Maximum load current
Insulating material
Solder pin surface
Flammability rating according to UL 94
Internal cylindrical gage
Stripping length
Number of positions
Screw thread
Tightening torque, min
Tightening torque max
76 A
PA
Sn
V0
B6
10 mm
3
M4
1.2 Nm
1.5 Nm
Connection data
Conductor cross section AWG min.
Conductor cross section AWG max.
2 conductors with same cross section, solid min.
2 conductors with same cross section, solid max.
2 conductors with same cross section, stranded min.
2 conductors with same cross section, stranded max.
2 conductors with same cross section, stranded, ferrules without plastic
sleeve, min.
2 conductors with same cross section, stranded, ferrules without plastic
sleeve, max.
2 conductors with same cross section, stranded, TWIN ferrules with
plastic sleeve, min.
2 conductors with same cross section, stranded, TWIN ferrules with
plastic sleeve, max.
20
6
0.5 mm²
6 mm²
0.5 mm²
6 mm²
0.5 mm²
4 mm²
0.5 mm²
6 mm²
Standards and Regulations
Connection in acc. with standard
Flammability rating according to UL 94
EN-VDE
CUL
V0
Environmental Product Compliance
China RoHS
Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”,
Category “Manufacturer's declaration”
Drawings
11/14/2016 Page 2 / 4
https://www.phoenixcontact.com/hq/products/1774153
PCB terminal block - MKDSP 10N/ 3-10,16 BK - 1774153
Drilling diagram
a
10,16
5,18
Dimensional drawing
18,4
a+10,16
3,2
10,16
1,5
+0,1
5
29,3
10,16
3,2
10,16
a
5,18
Approvals
Approvals
Approvals
VDE Gutachten mit Fertigungsüberwachung / CCA / IECEE CB Scheme / EAC / cULus Recognized
Ex Approvals
Approval details
VDE Gutachten mit Fertigungsüberwachung
Search.aspx 40035740
mm²/AWG/kcmil
Nominal current IN
Nominal voltage UN
http://www.vde.com/en/Institute/OnlineService/VDE-approved-products/Pages/Online-
0.5-16
76 A
1000 V
CCA CCA/ DE1 34205
mm²/AWG/kcmil
Nominal current IN
Nominal voltage UN
0.5-16
76 A
1000 V
IECEE CB Scheme
mm²/AWG/kcmil
Nominal current IN
http://www.iecee.org/ DE1-50962
0.5-16
76 A
11/14/2016 Page 3 / 4
https://www.phoenixcontact.com/hq/products/1774153
PCB terminal block - MKDSP 10N/ 3-10,16 BK - 1774153
Approvals
Nominal voltage UN
1000 V
EAC B.01742
cULus Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm E60425-19770427
mm²/AWG/kcmil
Nominal current IN
Nominal voltage UN
B
20-6
60 A
300 V
C
20-6
60 A
300 V
D
20-6
5A
600 V
Phoenix Contact 2016 © - all rights reserved