CATTEN-09R0
9dB Attenuator
SMA 50 Ohm
DC to 3GHz
Temperature Range:
Rated Power:
Freq Range.
VSWR:
Impedance:
Attenuation Tolerance:
-40°C to +85°C
1 Watt Max
DC - 3GHz
1:1.3 Max
50 Ohms
±0.5 dB Typical
Actual Size
The Attenuator offers end users a rugged SMA attenuator housing for easy connection.
The CATTEN-09R0 provides 1 Watt of power dissipation. Tolerance matching is used to
provide superior temperature tracking to individual components. Attenuator frequency
range is from DC to 3GHz.
Rev.: C
Date: 08-27-08
Part Number
CATTEN-01R0
CATTEN-02R0
CATTEN-03R0
CATTEN-05R0
CATTEN-06R0
CATTEN-07R0
CATTEN-08R0
CATTEN-09R0
CATTEN-0100
CATTEN-0200
CATTEN-0150
CATTEN-04R0
CATTEN-01R5
Attenuation
1.5 dB
2 dB
3 dB
5 dB
6 dB
4 dB
1 dB
Power
(Max)
1 Watt
1 Watt
1 Watt
1 Watt
1 Watt
1 Watt
1 Watt
1 Watt
1 Watt
0.5 Watt
0.5 Watt
1 Watt
1 Watt
CATTEN-09R0
9dB Attenuator
SMA 50 Ohm
DC to 3GHz
9 dB Data
Freq.
(MHz)
0.3
0.5
0.8
1.0
5.0
10.0
20.0
50.0
100.0
200.0
300.0
400.0
500.0
600.0
700.0
800.0
900.0
1000.0
1500.0
2000.0
2500.0
3000.0
Atten
(dB)
9.01
9.01
9.01
9.01
9.02
9.03
9.03
9.03
9.03
9.04
9.04
9.09
9.03
9.05
9.07
9.06
9.15
9.06
9.02
9.13
9.15
9.5
Return Loss
Male
(dB)
59
58
58
58
58
57
56
53
47
42
39
37
35
34
33
32
31
30
26
23
20
18
Female
(dB)
63
63
63
63
62
61
60
55
47
41
38
36
34
32
31
30
29
28
25
22
20
19
10 dB
15 dB
20 dB
7dB
8dB
9dB
TEST
Overload per EIA 575-3.6
Thermal Shock
Moisture Resistance
Condition of Test
Short time overload
per EIA 575-3.5
per EIA 575-3.7
per EIA 575-3.10
per EIA 575-3.12
Endurance Test at 70°C per EIA 575-3.14 1000 hours at 70°C, 1.5 hrs “ON”, 0.5 hrs “OFF”
0.5dB to 5dB
± 0.2 dB
± 0.2 dB
± 0.2 dB
± 0.2 dB
± 0.2 dB
± 0.2 dB
Test Results
6dB to 20dB
± 0.3 dB
± 0.3 dB
± 0.3 dB
± 0.3 dB
± 0.3 dB
± 0.3 dB
High Temperature Exposure
Low Temperature Exposure
Rev.: C
Date: 08-27-08