Fixed ("Y"which can be adjusted the output is available as optional:5V -5 to +10% : 12, 15, 24V
t
10%)
4.9 - 5.3
4.9 - 5.3
11.5 - 12.5
14.4 - 15.6
23.0 - 25.0
Works over 105% of rating (works over 105% of peak current at option -H) and recovers automatically
Works over 115% of rating, by zener diode clamping
Not provided
Not provided
Not provided
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
-10 to +60
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, CSA C22.2 No.60950-1 Complies with DEN-AN
Complies with FCC-B, VCCI-B
49
X
17
X
94mm (W
X
H
X
D) / 65g max
Convection
15
0.7
60max
120max
120max
160max
150max
180max
150max
60max
24
0.5
96max
150max
120max
160max
150max
180max
240max
96max
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C with the input voltage held constant at the rated input/output.
Please contact us about safety approvals for the model with option.
Fixed ("Y"which can be adjusted the output is available as optional:5V -5 to +10% : 12, 15, 24V
t
10%)
4.9 - 5.3
11.5 - 12.5
14.4 - 15.6
23.0 - 25.0
Works over 105% of rating and recovers automatically
Works over 115% of rating, by zener diode clamping
Not provided
Not provided
Not provided
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
-10 to +60
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, CSA C22.2 No.60950-1 Complies with DEN-AN
Complies with FCC-B, VCCI-B
50
X
17
X
115mm (W
X
H
X
D) / 80g max
Convection
INPUT
LCA
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*3
*
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C with the input voltage held constant at the rated input/output.
Please contact us about safety approvals for the model with option.
Fixed ("Y"which can be adjusted the output is available as optional:5V -5 to +10% : 12, 15, 24, 36, 48V
t
10%)
4.9 - 5.3
11.5 - 12.5
14.4 - 15.6
23.0 - 25.0
34.5 - 37.5
46.0 - 50.0
xx
Works over 105% of rating and recovers automatically
4.00V min
Works over 115% of rating, by zener diode clamping
Not provided
Not provided
Not provided
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
-10 to +60
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, CSA C22.2 No.60950-1 Complies with DEN-AN
Complies with FCC-B, VCCI-B
50
X
25
X
132.5mm (W
X
H
X
D) / 150g max
Convection
INPUT
LCA
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*3
*
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C with the input voltage held constant at the rated input/output.
Please contact us about safety approvals for the model with option.
ADI 近日宣布日立公司在其最新的消费类无线传输集线器 TP-WL700H 中使用 ADI 公司的 Advantiv ™高级电视解决方案 IC ,以提供高端的无线功能、灵活性和无缝高清 (HD) 连接。这款 TP-WL700H 集线器仅在日本市场供应,它是一款单机设备,专门用于为日立 Wooo UT 系列液晶电视提供无线高清娱乐内容。在日立公司最新的无线视...[详细]
2008年7月17~18日,由深圳创意时代主办的“第四届便携式产品设计与电源管理技术研讨会”在深圳隆重召开。为期两天的大会紧紧围绕便携产品设计、便携电源管理两大主题展开,引起了关于便携主题的广泛讨论。国际知名企业TI、ST 、ADI倾情参与,知名行业分析机构IN-Stat China 预测了行业的最新趋势,3M、飞兆、英飞凌、精工、爱国者、中电等国内外著名企业都发表了精彩演讲。 精彩的...[详细]