Against overvoltage, protection technology: tripping
if U > 1.5 x Un
Against short-circuits, protection technology: manual
or automatic reset
Against undervoltage, protection technology: tripping
if U < 0.8 x Un
0...60 °C without derating
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Output voltage
Rated power in W
Input protection type
Power supply output
current
Output protection type
Ambient air tempera-
ture for operation
Complementary
Input voltage limits
Network frequency
Inrush current
Cos phi
Efficiency
Output voltage limits
Power dissipation in W
Current consumption
Line and load regulation
Residual ripple
Holding time
Connections - terminals
100...250 V
85...264 V
47...63 Hz
<= 30 A
0.98
> 85 %
100...120 % adjustable
25.4 W
1 A at 100 V
0.6 A at 240 V
+/- 3 %
<= 200 mV
>= 20 ms at 100 V
>= 20 ms at 240 V
Screw type terminals for input connection, connection capacity: 2 x 0.14...2 x 2.5
mm²AWG gauge26...14
Screw type terminals for input ground connection, connection capacity: 1 x
0.14...1 x 2.5 mm²AWG gauge26...14
Screw type terminals for output connection, connection capacity: 4 x 0.14...4 x
2.5 mm²AWG gauge26...14
Screw type terminals for output ground connection, connection capacity: 2 x
0.14...2 x 2.5 mm²AWG gauge26...14
CE
35 x 15 mm symmetrical DIN rail
35 x 7.5 mm symmetrical DIN rail
75 x 7.5 mm symmetrical DIN rail
Vertical
Parallel
Series
Marking
Mounting support
Operating position
Output coupling
Jan 16, 2017
1
Name of test
Conducted/Radiated emissions conforming to EN 55011
Conducted/Radiated emissions conforming to EN 55022 Class B
Electrostatic discharges conforming to EN/IEC 61000-4-2
Emission conforming to EN 50081-1
Induced electromagnetic field conforming to EN/IEC 61000-4-6
Primary outage conforming to IEC 61000-4-11
Radiated electromagnetic field conforming to EN/IEC 61000-4-3
Rapid transient conforming to IEC 61000-4-4
Surge conforming to EN/IEC 61000-4-5
1 LED green for output voltage
1 LED orange for input voltage
120 mm
120 mm
54 mm
1 kg
Status LED
Depth
Height
Width
Product weight
Environment
Product certifications
CCSAus
CSA 22-2 No 950-1
C-Tick
CULus 508
TUV 60950-1
EMC conforming to EN 50081-1
EMC conforming to EN 50082-2
EMC conforming to EN/IEC 61000-6-2
Safety conforming to EN/IEC 60950
Safety conforming to IEC 61496-1-2
Safety conforming to SELV
IP20 conforming to EN/IEC 60529
-25...70 °C
0...95 % without condensation or dripping water
Class I conforming to VDE 0106-1
3000 V between input and ground
3000 V between input and output
500 V between output and ground
500 V between outputs
Compliant
0623
Environmental characteristic
IP degree of protection
Ambient air temperature for storage
Relative humidity
Class of protection against electric shock
Dielectric strength
RoHS EUR status
RoHS EUR conformity date
2
Product data sheet
Dimensions Drawings
ABL7RP4803
Regulated Switch Mode Power Supply
Dimensions and Mounting
Mounting on 35 mm/1.37 in. or 75 mm/2.95 in. Rail
3
Product data sheet
Connections and Schema
ABL7RP4803
Regulated Switch Mode Power Supply
Internal Wiring Diagram
(1)
Filter
Regulated Switch Mode Power Supplies
Series or Parallel Connection
Series Connection
(1)
Two Shottky diodes Imin = power supply In and Vmin = 50 V
Parallel Connection
Family
ABL 8REM/7RP
Series
2 products max.
Parallel
2 products max.
Series or parallel connection is only recommended for products with identical references.
4
Product data sheet
Performance Curves
ABL7RP4803
Regulated Switch Mode Power Supplies
Derating
The ambient temperature is a determining factor that limits the power an electronic power supply can deliver continuously. If the temperature
around the electronic components is too high, their life will be significantly reduced.
The nominal ambient temperature for the Optimum range of Phaseo power supplies is 50 °C. Above this temperature, derating is necessary
up to a maximum temperature of 60 °C.
The graph below shows the power as a percentage of the nominal power that the power supply can deliver continuously, depending on the
ambient temperature.
X
(1)
Maximum operating temperature (°C)
ABL 8REM, ABL 7RP mounted vertically
Derating should be considered in extreme operating conditions:
● Intensive operation (output current permanently close to the nominal current, combined with a high ambient temperature)
● Output voltage set above 24 Vdc (to compensate for line voltage drops, for example)