Halogen and Antimony Free. “Green” Device (Note 3)
(TOP View)
3. OUTPUT
2. GND
1. V
DD
SIP-3L
Applications
Smart E-Meters
Tamper Protection Switch
Door, Lids and Tray Position Switch
Proximity and Position Switches
Level Detects
On/Off Switch Digital Contact-Less Switch in Industrial and
Consumer Products
Notes:
1. No purposely added lead. Fully EU Directive 2002/95/EC (RoHS) & 2011/65/EU (RoHS 2) compliant.
2. See http://www.diodes.com/quality/lead_free.html for more information about Diodes Incorporated’s definitions of Halogen- and Antimony-free, "Green"
and Lead-free.
3. Halogen- and Antimony-free "Green” products are defined as those which contain <900ppm bromine, <900ppm chlorine (<1500ppm total Br + Cl) and
6. Stresses greater than the 'Absolute Maximum Ratings' specified above may cause permanent damage to the device. These are stress ratings only;
functional operation of the device at these or any other conditions exceeding those indicated in this specification is not implied. Device reliability may be
affected by exposure to absolute maximum rating conditions for extended periods of time.
7. The absolute maximum V
DD
of 7V is a transient stress rating and is not meant as a functional operating condition. It is not recommended to
operate the device at the absolute maximum rated conditions for any period of time.
Recommended Operating Conditions
(@T
A
= +25°C, unless otherwise specified.)
Symbol
V
DD
V
OUT_MAX
T
A
Characteristic
Supply Voltage
Maximum output pin voltage
Operating Temperature Range
Operating
Operating
Operating
Conditions
Rating
2.5 to 5.5
5.5
-40 to +125
Unit
V
V
C
Electrical Characteristics
Symbol
V
OUT_ON
I
OFF
(@T
A
= +25°C, V
DD
= 3V, unless otherwise specified.)
Conditions
I
OUT
= 1mA
V
OUT
= 5.5V, Output off
During ‘awake’ period,
T
A
= +25°C, V
DD
= 3V
During ‘awake’ period,
T
A
= -40 to +125°C, V
DD
= 2.5V to 5.5V
During ‘sleep’ period,
T
A
= +25°C, V
DD
= 3V
During ‘sleep’ period,
T
A
= -40 to +125°C, V
DD
= 2.5V to 5.5V
Min
—
—
—
—
—
—
—
—
—
—
—
Typ
0.1
<
0.1
3
—
5
—
8
-
75
75
0.1
Max
0.3
1
6
12
10
28
16
40
125
125
—
Unit
V
µA
mA
mA
µA
µA
µA
µA
µs
ms
%
Characteristic
Output On Voltage (V
OL
)
Output Leakage Current
I
DD
(awake)
Supply Current
I
DD
(sleep)
I
DD
(sleep)
I
DD
(avg)
Tawake
Tperiod
D.C.
Note:
Average Supply Current
Awake Time
Period
Duty Cycle
T
A
= 25°C, V
DD
= 3V
T
A
= -40 to +125°C, V
DD
= 2.5V to 5.5V
(Note 8)
(Note 8)
8. When power is initially turned on, the operating V
DD
must be within its correct operating range (2.5V to 5.5V) to guaranteed the output sampling.
The output state is valid after the second operating cycle (typical 150ms).
10. Parameters values over operating temperature range are not tested in production, they are guaranteed by design, process control and characterization.
The magnetic characteristics may vary with supply voltage, operating temperature and after soldering.
11. Maximum and minimum hysteresis is guaranteed by design and characterization.
故障现象是:
选择options for target "target1",进入debug菜单,选中"keil monitor-51driver"进入settings,正常设置后,在monitor-51 identification中显"示monitor-51 not conneted".
......
语音作为自然的人机接口,可以使车载导航系统实现更安全、更人性化的操作。通过国内外车载导航系统的功能对比可知,支持语音交互是车载导航系统的一个发展趋势。另外,市场信息服务公司J.D Power and Associates的调研数据也表明,56%的消费者更倾向于选择声控的导航系统。因此,开发车载语音导航系统是很有意义的。目前,国内已经具备开发车载语音导航系统的技术基础,特别是文语转换TTS技术...[详细]
“tensymetry”这个词在《韦伯斯特词典》中没有解释,但在医学界却广为人知。由Tensys Medical Systems公司开发的tensymetry是一种使用生物机械、电气、软件工程的专有组合技术。利用这三种强大的技术,你可在手术室内对病人的心跳血压进行精确、连续、实时和非侵入性测量。 该技术结出的果实就是该公司的T-line Tensymeter产品。该产品线的最新进展是去年...[详细]
SynQor推出超小的病人全接触型400W医疗电源模块,该电源模块的封装为3×5×1.44,功率密度高达18.3W/立方英寸,转换效率达91%。 SynQor通过推出首款专门针对医疗应用而研制的AC/DC电源模块,使得公司的多元化战略持续成功地延伸至新的医疗领域。ACuQor模块系列实现了在3×5×1.44有限尺寸上提供400W的有用功率。SynQor可以提供48V,36V or 24V的...[详细]