ELECTRICAL SOLUTIONS
A.
System
Overview
Code Conductor, Two-Hole, Long Barrel with Corona Relief Taper Lug
To Facilitate Use with Stranded Copper Conductors in Applications of 5000 V or More
Type LCCH
• Externally chamfered barrel end inhibits Corona effect when used
in high voltage applications
• Long barrel maximizes number of crimps and provides premium
wire pull-out strength and electrical performance
• Color-coded barrels marked with Panduit and specified competitor
die index numbers for proper crimp die selection
• Enclosed barrel prevents corrosive material from entering barrel
when used in harsh environments
• Tin-plated to inhibit corrosion
• UL Listed and CSA Certified to 35 KV** and temperature rated
to 90°C when crimped with Panduit and specified competitor
crimping tools and dies
• Available with NEMA hole sizes and spacing
B1.
Cable Ties
B2.
Cable
Accessories
B3.
Stainless
Steel Ties
C1.
Wiring
Duct
W
CORONA
RELIEF
TAPER
C2.
Surface
Raceway
HOLE
SPACING
L
B
C3.
Abrasion
Protection
Corona Relief Taper
T
C4.
Cable
Management
Part Number
LCCH1/0-12-X
LCCH2/0-12-X
LCCH3/0-12-X
◆
LCCH4/0-12-X
◆
LCCH250-12-X
◆
LCCH300-12-X
◆
LCCH350-12-X
◆
LCCH400-12-6
◆
LCCH500-12-6
◆
LCCH600-12-6
◆
LCCH750-12-6
◆
LCCH1000-12-3
D1.
Terminals
Copper
Conductor
Size
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
250 kcmil
300 kcmil
350 kcmil
400 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil
Stud
Hole
Size
(In.)
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
Stud
Hole
Spacing
(In.)
1.75
1.75
1.75
1.75
1.75
1.75
1.75
1.75
1.75
1.75
1.75
1.75
Figure Dimensions
(In.)
W
0.80
0.85
0.96
1.06
1.17
1.19
1.28
1.39
1.54
1.70
1.89
2.17
B
1.44
1.50
1.50
1.56
1.61
2.24
2.24
2.30
2.50
2.69
2.88
3.00
T
0.12
0.13
0.13
0.14
0.14
0.16
0.17
0.18
0.22
0.26
0.26
0.32
L
4.86
4.98
5.03
5.13
5.23
5.94
5.99
6.10
6.36
6.63
7.04
7.29
Panduit
Color
Code
Pink
Black
Orange
Purple
Yellow
White
Red
Blue
Brown
Green
Black
White
Panduit
Burndy
T&B
Wire Strip Std.
Die Index Die Index Die Index
Length Pkg.
No.‡
No.‡
No.‡
(In.)
Qty.
P42
12
42
1 1/2
10
P45
P50
P54
P62
P66
P71
P76
P87
P94
P106
P125
13
14
15
16
17
18
19
20
22
24
27
45
50
54
62
66
71
76
87
94
106
125
1 9/16
1 9/16
1 5/8
1 1/16
2 5/16
2 5/16
2 3/8
2 9/16
2 3/4
2 15/16
3 1/16
10
10
10
10
10
10
6
6
6
6
3
D2.
Power
Connectors
D3.
Grounding
Connectors
E1.
Labeling
Systems
E2.
Labels
‡See pages D3.66, D3.67 for tool and die information.
**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V.
◆NEMA
hole sizes and spacing.
E3.
Pre-Printed
& Write-On
Markers
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
F.