https://www.phoenixcontact.com/us/products/2948856
Solid-state relay module - EMG 12-OV-220DC/240AC/1 - 2948856
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Power solid-state relay, with LED and protective circuit in input and output circuits, input: 220 V DC, output: 24 -
280 V AC/max. 1 A
The illustration shows version EMG
12-OV, with AC voltage output, max.
1A
Key Commercial Data
Packing unit
GTIN
Weight per Piece (excluding packing)
Custom tariff number
Country of origin
41.48 g
85364900
Germany
1 pc
Technical data
Dimensions
Width
Height
Depth
12.5 mm
75 mm
102 mm
Ambient conditions
Ambient temperature (operation)
Ambient temperature (storage/transport)
Degree of protection
-20 °C ... 60 °C
-20 °C ... 70 °C
IP20
Input data
Nominal input voltage U
N
220 V DC
04/27/2016 Page 1 / 4
https://www.phoenixcontact.com/us/products/2948856
Solid-state relay module - EMG 12-OV-220DC/240AC/1 - 2948856
Technical data
Input data
Input voltage range in reference to U
N
Switching threshold "0" signal in reference to U
N
Switching threshold "1" signal in reference to U
N
Typical input current at U
N
Typical response time
Typical turn-off time
Status display
Type of protection
Protective circuit/component
Transmission frequency
0.8 ... 1.1
≤ 0.4
≥ 0.8
3 mA
max. one half cycle - zero-voltage crossing
max. one half cycle - zero-current crossing
Yellow LED
Reverse polarity protection
Surge protection
Polarity protection diode
Varistor
25 Hz
Output data
Output nominal voltage
Output voltage range
Limiting continuous current
Min. load current
Leakage current
Surge current
Max. load value
Peak offstate voltage
Voltage drop at max. limiting continuous current
Output circuit
Type of protection
Protective circuit/component
240 V AC
24 V AC ... 280 V AC (50 Hz ... 60 Hz)
1 A (see derating curve)
50 mA
2.5 mA
125 A (t = 10 ms)
78 A s (I x t where t = 10 ms)
600 V (Periodic peak reverse voltage)
≤ 1.5 V
2-wire, floating
RC element
RC element
2
2
Connection data, input side
Connection name
Connection method
Stripping length
Screw thread
Conductor cross section solid
Conductor cross section flexible
Conductor cross section AWG
Input side
Screw connection
8 mm
M3
0.2 mm² ... 4 mm²
0.2 mm² ... 2.5 mm²
24 ... 12
Connection data, output side
Connection name
Connection method
Output side
Screw connection
04/27/2016 Page 2 / 4
https://www.phoenixcontact.com/us/products/2948856
Solid-state relay module - EMG 12-OV-220DC/240AC/1 - 2948856
Technical data
Connection data, output side
Stripping length
Screw thread
Conductor cross section solid
Conductor cross section flexible
Conductor cross section AWG
8 mm
M3
0.2 mm² ... 4 mm²
0.2 mm² ... 2.5 mm²
24 ... 12
General
Test voltage input/output
Mounting position
Assembly instructions
Operating mode
Flammability rating according to UL 94
Standards/regulations
3.5 kV AC
3.5 kV AC
any
Mounted in rows with zero spacing: Horizontal/not in rows: Any
100% operating factor
V0
IEC 60664
EN 50178
IEC 62103
Rated surge voltage/insulation
Basic insulation
Standards and Regulations
Standards/regulations
IEC 60664
EN 50178
IEC 62103
Rated surge voltage/insulation
Flammability rating according to UL 94
Basic insulation
V0
Classifications
eCl@ss
eCl@ss 4.0
eCl@ss 4.1
eCl@ss 5.0
eCl@ss 5.1
eCl@ss 6.0
eCl@ss 7.0
27371102
27371102
27371001
27371001
27371001
27371001
ETIM
ETIM 2.0
ETIM 3.0
EC001504
EC001504
04/27/2016 Page 3 / 4
https://www.phoenixcontact.com/us/products/2948856
Solid-state relay module - EMG 12-OV-220DC/240AC/1 - 2948856
Classifications
ETIM
ETIM 4.0
ETIM 5.0
EC001504
EC001504
UNSPSC
UNSPSC 6.01
UNSPSC 7.0901
UNSPSC 11
UNSPSC 12.01
UNSPSC 13.2
30211916
39121542
39121542
39121542
39121542
Accessories
Accessories
Marking material - EMG-GKS 12 - 2947035
Equipment marker, width 12 mm
Drawings
Diagram
Load current [A]
Circuit diagram
1,5
1
0,5
0
20
30
40
50
60
Ambient temperature [°C]
A2
-
DC
14 A2
AC
14
2
1
A1
+
13 A1
13
1
In rows with zero spacing
2
stand-alone device
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com