ILB PB 24 DO32
Inline Block IO Module
for PROFIBUS With 32 Digital Outputs
AUTOMATIONWORX
Data Sheet
6889_en_04
Description
The ILB PB 24 DO32 module is designed for use within a
PROFIBUS network. It is used to output digital signals.
PROFIBUS-DP Features
–
–
–
–
–
–
Bus connection via D-SUB connectors
Rotary encoding switches for address setting
Supported PROFIBUS addresses 1 to 99
Transmission speed 9.6 kbaud to 12 Mbaud (autobaud)
Diagnostic and status indicators
Device description via GSD file
© PHOENIX CONTACT - 03/2007
6 8 8 9 A 0 0 1
Output Features
–
–
–
–
–
–
Connections for 32 digital actuators
Connection of actuators in 2 and 3-wire technology
Nominal current per output: 0.5 A
Total current of all outputs: 16 A (4 x 4 A)
Short-circuit and overload protected outputs
Diagnostic and status indicators
Please refer to the "Mounting and Removing Inline Block IO Modules" application note (see "Ordering Data"
on page 2).
Make sure you always use the latest documentation.
It can be downloaded at
www.download.phoenixcontact.com.
A conversion table is available on the Internet at
www.download.phoenixcontact.com/general/7000_en_00.pdf.
ILB PB 24 DO32
Ordering Data
Product
Description
Inline Block IO module for PROFIBUS with 32 digital outputs
Type
ILB PB 24 DO32
Order No.
2862408
Pcs./Pkt.
1
Accessories: Connector
Description
9-pos. D-SUB connector for connecting PROFIBUS
Type
SUBCON-PLUS-PROFIB
Order No.
2744348
Pcs./Pkt.
1
Accessories: Connectors as Replacement Item
Description
Connector for the supply (color print)
Connector, with color print, for digital 4-channel or 16-channel Inline output
terminals
Type
ILB SCN-12-PWR IN-CP
IB IL SCN-12-OCP
Order No.
2863164
2727624
Pcs./Pkt.
10
10
Accessories: Other
Description
Recommended end clamp; placed both to the right and left of the module to
secure it on the DIN rail
Type
CLIPFIX 35-5
Order No.
3022276
Pcs./Pkt.
50
Documentation
Description
"Mounting and Removing Inline Block IO Modules" application note
"Addressing of 32-Channel ILB Modules" application note
Type
AH ILB INSTALLATION
AH ILB 24 DI/DO 32 ADDRESS
Order No.
9014931
9014963
Pcs./Pkt.
1
1
6889_en_04
PHOENIX CONTACT
2
ILB PB 24 DO32
Technical Data
General Data
Housing dimensions with connectors (width x height x depth)
Weight
Operating mode
Transmission speed
Connection method for actuators
156 mm x 55 mm x 141 mm
510 g (with connectors)
Process data mode with 4 bytes
9.6 kbaud to 12 Mbaud (autobaud)
2 and 3-wire technology
Housing Dimensions
156
55
141
120
6889B003
Figure 1
Housing dimensions of the module (dimensions in mm)
Ambient Conditions
Regulations
Ambient temperature (operation)
Ambient temperature (storage/transport)
Humidity (operation/storage/transport)
Air pressure (operation)
Air pressure (storage/transport)
Degree of protection according to IEC 60529
Class of protection
Air and creepage distances
Housing material
Pollution degree according to
EN 60664-1/IEC 60664-1, EN 61131-2/IEC 61131-2
Surge voltage class
Developed according to VDE 0160/EN 50178/IEC 62103, UL 508
-25°C to +60°C
-25°C to +85°C
10% to 95% according to EN 61131-2
80 kPa to 108 kPa (up to 2000 m above sea level)
66 kPa to 108 kPa (up to 3500 m above sea level)
IP20
Class 3 according to VDE 0106/IEC 60536
According to DIN VDE 0110/IEC 60664, IEC 60664A,
DIN VDE 0160/EN 50178/IEC 62103
Plastic, PVC-free, PBT, self-extinguishing (V0)
2; condensation not permitted during operation
II
6889_en_04
PHOENIX CONTACT
3
ILB PB 24 DO32
Electrical Isolation/Isolation of the Voltage Areas
Test Distance
PROFIBUS / I/O
PROFIBUS / functional earth ground
I/O / functional earth ground
Test Voltage
500 V AC, 50 Hz, 1 min
500 V AC, 50 Hz, 1 min
500 V AC, 50 Hz, 1 min
Mechanical Requirements
Vibration test, sinusoidal vibrations according to
EN 60068-2-6/IEC 60068-2-6
Shock test according to EN 60068-2-27/IEC 60068-2-27
Broadband noise according to EN 60068-2-64/IEC 60068-2-64
5g load, 2.5 hours in each space direction
25g load for 11 ms, half sinusoidal wave,
3 shocks in each space direction and orientation
0.78g load, 2.5 hours in each space direction
Conformance With EMC Directive 89/336/EEC
Noise Immunity Test According to EN 61000-6-2
Electrostatic discharge (ESD)
EN 61000-4-2
IEC 61000-4-2
EN 61000-4-3
IEC 61000-4-3
EN 61000-4-4/
IEC 61000-4-4
Criterion B
6 kV contact discharge
8 kV air discharge
Criterion A
Field strength: 10 V/m
Criterion B
Remote bus: 2 kV
Power supply: 2 kV
I/O cables: 2 kV
Criterion A
All interfaces: 1 kV
Surge voltage
EN 61000-4-5
IEC 61000-4-5
EN 61000-4-6
IEC 61000-4-6
Criterion B
DC supply lines: ±0.5 kV/±1.0 kV (symmetrical/asymmetrical)
Signal cables: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
Conducted interference
Criterion A
Test voltage 10 V
Class A
Electromagnetic fields
Fast transients (burst)
Noise Emission Test According to EN 61000-6-4
Noise emission of housing
EN 55011
Interface
PROFIBUS interface
Copper cable (RS-485); connected via D-SUB connector;
shielding directly connected with functional earth ground
24 V Module Supply (Communications Power and Actuator Supply; U
L
and U
A
)
Nominal value
Tolerance
Ripple
Permissible range
Current consumption at U
L
Current consumption at U
A1
and U
A2
Safety equipment for communications power
Safety equipment for the actuator supply
Connection
24 V DC
-15%/+20% according to EN 61131-2
±5% according to EN 61131-2
19.2 V DC to 30.0 V DC
70 mA
8 A each
Surge protection and protection against polarity reversal
Surge protection
Via power connectors
6889_en_04
PHOENIX CONTACT
4
ILB PB 24 DO32
Digital Outputs
Number
Connection method for actuators
Nominal output voltage U
OUT
Differential voltage at I
nom
Nominal current I
nom
per channel
Total current
Protection
Nominal load
Ohmic
Lamp
Inductive
Switching frequency with nominal inductive load
Overload response
Response with inductive overload
Reverse voltage protection against short pulses
Resistance to permanently applied reverse voltages
Validity of output data after connecting the 24 V supply voltage (power up)
Response upon power down
Limitation of the voltage induced on circuit interruption
One-time unsolicited energy
Protective circuit type
Overcurrent shutdown
Maximum output current when switched off
48
Ω/12
W
12 W
12 VA (1.2 H, 50
Ω)
0.5 Hz (1.2 H, 50
Ω),
maximum
Auto restart
Output may be damaged
Protected against reverse voltages
Protected against reverse voltages, permissible current 2 A, maximum
1 ms, typical
The output follows the supply voltage without delay.
-41.0 V
1 J, maximum
Integrated free running circuit in the output chip
0.7 A, minimum
10 µA
32
2 and 3-wire technology
24 V DC
≤
1V
0.5 A
4x4A
Short-circuit and overload protection
When not loaded, a voltage can be measured even at an output that is not set.
Typical Power Dissipation With 24 V Supply Voltage
Formula to Calculate the Power Dissipation of the Electronics
P
TOT
= 1.45 W +
S
(0.11 W + I
Li
x 0.28
W
)
2
n
i=1
Where
P
TOT
i
n
I
Li
Total power dissipation of the module
Index
Number of set outputs (n = 1 to 32)
Load current of the output i
Limitation of Simultaneity, Derating
Ambient Temperature (TA)
-25°C to +45°C
+46°C to +60°C
Maximum Load Current (I)
at 100% Simultaneity
32 x 0.5 A
32 x 0.4 A
Maximum Load Current (I)
at 50% Simultaneity
16 x 0.5 A
16 x 0.5 A
Approvals
For the latest approvals, please visit
www.download.phoenixcontact.com.
6889_en_04
PHOENIX CONTACT
5