ELECTRICAL SOLUTIONS
A.
System
Overview
Flex Conductor, Two-Hole, Long Barrel with Window Lug, 90° Angle
For Use with Flexible, Extra-Flexible, and Code Stranded Copper Conductors
Type LCCX-F
• Can be used with code conductor and flex conductor class: G, H, I,
K, M and Diesel Locomotive
• Long barrel maximizes number of crimps and provides premium
wire pull-out strength and electrical performance
• Generously beveled wire entry prevents bent back strands when
inserting conductor into barrel
• Color-coded barrels marked with Panduit and specified competitor
die index numbers for proper crimp die selection
• Inspection window to visually assure full conductor insertion
• Tin-plated to inhibit corrosion
• UL Listed and CSA Certified to 35 KV** and temperature rated to
90°C when crimped with Panduit and specified competitor
crimping tools and dies
• Meets J-STD-607-A and TIA-942 requirements for network
systems grounding applications
• Available with NEMA hole sizes and spacing
B1.
Cable Ties
B2.
Cable
Accessories
B3.
Stainless
Steel Ties
C1.
Wiring
Duct
W
HOLE
SPACING
INSPECTION
WINDOW
C2.
Surface
Raceway
T
90˚
B
C3.
Abrasion
Protection
Stud
Hole
Size
(In.)
#10
#10
#8 AWG
#8 AWG
#8 AWG
1/4
1/4
1/4
3/8
#10
1/4
1/4
#6 AWG
#6 AWG
#6 AWG
1/4
3/8
3/8
3/8
1/4
#4 AWG
#5, #4, #3
AWG
#4 AWG
1/4
3/8
3/8
1/4
#2 AWG
#2 AWG
#2 AWG
1/4
3/8
1/2
1/4
1/4
#1 AWG
#1 AWG
#1 AWG
1/4
5/16
5/16
3/8
1/4
1/0 AWG
1/0 AWG
1/0 AWG
1/4
3/8
1/2
L
C4.
Cable
Management
Part Number
LCCX8-10AF-L
LCCX8-10BF-L
LCCX8-14AF-L
LCCX8-14BF-L
LCCX8-14DF-L
Flex Conductor Size
Code
Class G,
Diesel
Conductor
H, I, K, M Locomotive
Size
Figure Dimensions
Stud
(In.)
Hole
Spacing
(In.)
W
B
T
L
0.63
0.41 0.70 0.08 1.53
0.75
0.63
0.75
1.00
1.00
0.75
0.63
0.75
1.00
0.63
0.88
1.00
0.63
0.75
0.75
1.00
0.63
0.75
1.00
1.75
0.63
0.75
1.00
0.88
1.00
1.00
0.63
0.75
1.00
1.75
0.41 0.70 0.08 1.65
0.48 0.70 0.07 1.62
0.48 0.70 0.07 1.74
0.48 0.70 0.07 1.99
0.60 0.70 0.05 2.21
0.46 1.07 0.08 1.69
0.48 1.07 0.08 1.66
0.48 1.07 0.08 1.78
0.48 1.07 0.08 2.03
0.62 1.07 0.06 1.88
0.62 1.07 0.06 2.13
0.62 1.07 0.06 2.25
0.55 1.05 0.09 1.74
0.55 1.05 0.09 1.87
0.62 1.05 0.08 2.09
0.62 1.05 0.08 2.34
0.70 1.36 0.11 1.94
0.70 1.36 0.11 2.06
0.70 1.36 0.11 2.51
0.75 1.36 0.09 3.68
0.76 1.44 0.12 2.08
0.76 1.44 0.12 2.20
0.76 1.44 0.12 2.45
0.76 1.44 0.12 2.38
0.76 1.44 0.12 2.51
0.76 1.44 0.12 2.58
0.85 1.50 0.13 2.22
0.85 1.50 0.13 2.34
0.85 1.50 0.13 2.66
0.85 1.50 0.13 3.82
Burndy T&B
Wire
Panduit Panduit
Die
Die
Strip Std.
Color Die Index Index Index Length Pkg.
No.
No.
(In.)
Code
No.‡
Qty.
Red
P21
49
21
3/4
50
Red
Red
Red
Red
Red
Blue
Blue
Blue
Blue
Blue
Blue
Blue
Gray
Gray
Gray
Gray
Brown
Brown
Brown
Brown
Green
Green
Green
Green
Green
Green
Pink
Pink
Pink
Pink
P21
P21
P21
P21
P21
P24
P24
P24
P24
P24
P24
P24
P29
P29
P29
P29
P33
P33
P33
P33
P37
P37
P37
P37
P37
P37
P42
P42
P42
P42
49
49
49
49
49
7
7
7
7
7
7
7
8
8
8
8
10
10
10
10
11
11
11
11
11
11
12
12
12
12
21
21
21
21
21
24
24
24
24
24
24
24
29
29
29
29
33
33
33
33
37
37
37
37
37
37
42
42
42
42
3/4
3/4
3/4
3/4
3/4
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
1 7/16
1 7/16
1 7/16
1 7/16
1 1/2
1 1/2
1 1/2
1 1/2
1 1/2
1 1/2
1 9/16
1 9/16
1 9/16
1 9/16
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
20
20
20
20
10
10
10
10
10
10
10
10
10
10
D1.
Terminals
D2.
Power
Connectors
LCCX8-38DF-L
LCCX6-10BF-L
LCCX6-14AF-L
LCCX6-14BF-L
LCCX6-14DF-L
LCCX6-38AF-L
LCCX6-38CF-L
LCCX6-38DF-L
D3.
Grounding
Connectors
E1.
Labeling
Systems
LCCX4-14AF-L
LCCX4-14BF-L
LCCX4-38BF-L
LCCX4-38DF-L
E2.
Labels
LCCX2-14AF-E
LCCX2-14BF-E
LCCX2-38DF-E
LCCX2-12F-E
LCCX1-14AF-X
LCCX1-14BF-X
LCCX1-14DF-X
LCCX1-56CF-X
LCCX1-56DF-X
LCCX1-38DF-X
LCCX1/0-14AF-X
LCCX1/0-14BF-X
LCCX1/0-38DF-X
LCCX1/0-12F-X
E3.
Pre-Printed
& Write-On
Markers
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
F.
Index
‡See pages D3.70 – D3.73
for tool and die information.
*Not UL Listed or CSA Certified with Class K flex conductor when crimped with Burndy tools.
**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V.
Order number of pieces required, in multiples of Standard Package Quantity.
Prime items appear in
BOLD.
D2.94
ELECTRICAL SOLUTIONS
Flex Conductor, Two-Hole, Long Barrel with Window Lug, 90° Angle (continued)
Stud
Hole
Size
(In.)
1/4
1/4
3/8
1/2
3/0 AWG
3/0 AWG
3/0 AWG
1/4
3/8
1/4
4/0 AWG
4/0 AWG
4/0 AWG
3/8
1/2
250 kcmil
300 kcmil
262.6 kcmil
313.1 kcmil
—
—
1/4
3/8
3/8
1/2
1/4
350 kcmil
373.7 kcmil
—
3/8
1/2
Stud
Hole
Spacing
(In.)
W
B
T
L
0.63
0.96 1.50 0.13 2.29
0.75
1.00
1.75
0.75
1.00
0.75
1.00
1.75
0.75
1.00
1.00
1.75
0.75
1.00
1.75
0.96 1.50 0.13 2.42
0.96 1.50 0.13 2.73
0.96 1.50 0.13 3.89
1.06 1.56 0.14 2.50
1.06 1.56 0.14 2.84
1.19 2.24 0.16 2.69
1.19 2.24 0.16 2.88
1.19 2.24 0.16 4.06
1.28 2.24 0.17 2.46
1.28 2.24 0.17 2.94
1.39 2.30 0.18 3.02
1.39 2.30 0.18 3.95
1.54 2.50 0.22 2.65
1.54 2.50 0.22 3.13
1.54 2.50 0.22 4.31
Figure Dimensions
(In.)
Burndy T&B
Wire
Panduit Panduit
Die
Die
Strip Std.
Color Die Index Index Index Length Pkg.
Code
No.‡
No.
No.
(In.)
Qty.
Black
P45
13
45
1 9/16 10
Black
Black
Black
Orange
Orange
Purple
Purple
Purple
Yellow
Yellow
Red
Red
Blue
Blue
Blue
P45
P45
P45
P50
P50
P54
P54
P54
P62
P62
P71
P71
P76
P76
P76
13
13
13
14
14
15
15
15
16
16
18
18
19
19
19
45
45
45
50
50
54
54
54
62
62
71H
71H
76H
76H
76H
1 9/16
1 9/16
1 9/16
1 5/8
1 5/8
2 5/16
2 5/16
2 5/16
2 5/16
2 5/16
2 3/8
2 3/8
2 9/16
2 9/16
2 9/16
10
10
10
10
10
10
10
10
10
10
6
6
6
6
6
A.
System
Overview
B1.
Cable Ties
Part Number
LCCX2/0-14AF-X
LCCX2/0-14BF-X
LCCX2/0-38DF-X
LCCX2/0-12F-X
LCCX3/0-14BF-X
LCCX3/0-38DF-X
LCCX4/0-14BF-X
LCCX4/0-38DF-X
N
LCCX4/0-12F-X
LCCX250-14BF-X
LCCX250-38DF-X
LCCX300-38DF-6
LCCX300-12F-6
LCCX350-14BF-6
LCCX350-38DF-6
N
LCCX350-12F-6
Flex Conductor Size
Code
Conductor
Class G,
Diesel
H, I, K, M Locomotive
Size
B2.
Cable
Accessories
2/0 AWG
2/0 AWG
2/0 AWG
B3.
Stainless
Steel Ties
C1.
Wiring
Duct
C2.
Surface
Raceway
‡See pages D3.70 – D3.73 for tool and die information.
*Not UL Listed or CSA Certified with Class K flex conductor when crimped with Burndy tools.
**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V.
NNEMA
hole sizes and spacing.
C3.
Abrasion
Protection
C4.
Cable
Management
Flex Conductor, Two-Hole, Long Barrel with Window, Narrow
Tongue Lug
For use with Flexible and Extra-Flexible Stranded Copper Copper Conductors
• Narrow tongue width for limited space applications
• Can be used with flex conductor class: G, H, I, K, M and Diesel
Locomotive
• Long barrel maximizes number of crimps and provides premium
wire pull-out strength and electrical performance
• Generously beveled wire entry prevents bent back strands when
inserting conductor into barrel
• Color-coded barrels marked with Panduit and specified competitor
die index numbers for proper crimp die selection
• Inspection window to visually assure full conductor insertion
• Tin-plated to inhibit corrosion
• UL Listed and CSA Certified to 35 KV** and temperature rated to
90°C when crimped with Panduit and specified competitor
crimping tools and dies
• Meets J-STD-607-A and TIA-942 requirements for network
systems grounding applications
• Available with NEMA hole sizes and spacing
D1.
Terminals
D2.
Power
Connectors
D3.
Grounding
Connectors
W
HOLE
SPACING
E1.
Labeling
Systems
L
B
E2.
Labels
INSPECTION
WINDOW
T
E3.
Pre-Printed
& Write-On
Markers
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
F.
Index
Flex Conductor Size
Part Number
N
LCCXN450-12-6
N
LCCXN500-12-6
N
LCCXN650-12-6
Class
G,H, I, K, M
450 kcmil
500 kcmil
—
Diesel
Locomotive
444.4 kcmil
535.3 kcmil
646.4 kcmil
Stud
Hole
Size
(In.)
1/2
1/2
1/2
Stud
Hole
Spacing
(In.)
1.75
1.75
1.75
Figure Dimensions
(In.)
W
1.19
1.30
1.35
B
2.69
2.88
2.94
T
0.33
0.32
0.36
L
6.41
6.71
6.78
Burndy
Panduit Panduit
Die
Color Die Index Index
Code
No.‡
No.‡
Brown
P87
20
Pink
Black
P99
P106
L99
24
T&B
Die
Index
No.‡
87H
99H
106
Wire
Strip Std.
Length Pkg.
Qty.
(In.)
2 3/4
6
2 15/16
3
6
6
‡See pages D3.70 – D3.73 for tool and die information.
**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V.
NNEMA
hole sizes and spacing.
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
D2.95