3120-F321-P7T1-W04K-X3120-M2P7M-230V-16A

产品描述Circuit Breakers An extremely versatile range of rocker switch/thermal circuit breakers
产品类别电路保护   
文件大小2MB,共16页
制造商E-T-A [E-T-A Circuit Breakers]
下载文档 详细参数 全文预览

3120-F321-P7T1-W04K-X3120-M2P7M-230V-16A在线购买

供应商 器件名称 价格 最低购买 库存  
3120-F321-P7T1-W04K-X3120-M2P7M-230V-16A - - 点击查看 点击购买

3120-F321-P7T1-W04K-X3120-M2P7M-230V-16A概述

Circuit Breakers An extremely versatile range of rocker switch/thermal circuit breakers

3120-F321-P7T1-W04K-X3120-M2P7M-230V-16A规格参数

参数名称属性值
Product AttributeAttribute Value
制造商
Manufacturer
E-T-A [E-T-A Circuit Breakers]
产品种类
Product Category
Circuit Breakers
RoHSDetails
产品
Product
Thermal Circuit Breakers
类型
Type
Thermal Overcurrent
电流额定值
Current Rating
16 A
电压额定值 AC
Voltage Rating AC
240 VAC
电压额定值 DC
Voltage Rating DC
50 VDC
Number of Poles2 Pole
Actuator TypeRocker
工作温度范围
Operating Temperature Range
- 30 C to + 60 C
IlluminatedNot Illuminated
高度
Height
25 mm
长度
Length
54 mm
端接类型
Termination Style
Blade
电压额定值
Voltage Rating
50 VDC, 240 VAC
宽度
Width
35 mm
安装风格
Mounting Style
Snap In
工厂包装数量
Factory Pack Quantity
1

文档预览

下载PDF文档
Thermal Circuit Breaker 3120-F...
Description
The 3120 circuit breaker/switch combination is an ON/OFF switch
with integral overcurrent protection (S-type TO CBE to EN/IEC
60934). The trip element is a bimetal. Type 3120 is ideally suited for
overload protection of motors, pumps, transformers and cables.
The 3120 circuit breaker is also available as a switch-only version in
accordance with the IEC/EN 61058 (see data sheet switch 3120-F-..Q1).
Product characteristics:
l
rocker or push button actuation
l
single pole and double pole versions
l
reliable switching behaviour (positively trip-free)
l
convenient snap-in mounting
l
international approvals
Options and add-on modules:
illumination
l
water splash protection
l
auxiliary contacts
l
under voltage trip
l
remote trip
l
magnetic trip
l
push-in terminals
l
appliance inlet module
l
1
Technical data
For details please see Technical information
Rated voltage
Current rating range
AC 240 V, DC 50 V
0.1...20 A
(up to 30A upon request for single pole
units)
30,000
30,000
30,000
30,000
operations
operations
operations
operations
at
at
at
at
at
at
at
at
1
1
1
1
1
1
1
1
x
x
x
x
x
x
x
x
I
N
,
I
N
,
I
N
,
I
N
,
I
N
,
I
N
,
I
N
,
I
N
,
inductive
inductive
resistive
inductive
inductive
inductive
inductive
inductive
Typical applications
Medical and laboratory equipment, apparatus and machine
construction, professional tools, household and garden appliances,
offices machines, audio equipment, machine tools
Typical life 1-pole
0.1...20 A
0.1...4 A
4.5...16 A
DC 28 V:
0.1...20 A
Typical life 2-pole
AC 240 V:
AC 240 V:
DC 50 V:
Current ratings and internal resistance values
Current rating
(A)
0.1
0.2
0.3
0.4
0.5
0.6
0.8
1
1.2
1.5
2
2.5
3
3.5
Internal
resistance
per pole (Ω)
94
24
12
5.30
4.20
2.90
1.50
0.9
0.80
0.45
0.27
0.0785
0.0595
0.0565
Current rating
(A)
4
4.5
5
6
7
8
10
12
14
15
16
18
20
Internal
resistance
per pole (Ω)
0.0435
0.0435
0.0325
0.0215
0.0165
0.0165
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
0.1...16 A 50,000 operations
17...20 A 30,000 operations
DC 50 V:
0.1...16 A 50,000 operations
17...20 A 50,000 operations
Ambient temperature
-30 … 60 °C
Insulation coordination
(IEC 60664)
Dielectric strength
Operating area
pole to pole (2-pole)
Insulation resistance
Interrupting capacity I
cn
2.5 kV /2 reinforced insulation at
operating area
test voltage AC 3,000 V
test voltage AC 1,500 V
> 100 MΩ (DC 500 V)
0.1...2 A
10 x I
N
2.5...20 A
1-pole 150 A
2-pole 250 A
Interrupting capacity (UL 1077)
I
N
1-pole, 2- pole
1-pole, 2- pole
0.1...20 A
0.1...20 A
U
N
AC 250 V
DC 50 V
I
nc
5000 A, C, 1
1000 A, C, 1
Degree of protection
(IEC 60529)
Vibration
Current consumption of illumination
Operating voltage
DC 12 V
DC 24 V
DC 48 V
AC 115 V
AC 230 V
Current consumption
Y
5.2 mA
4.5 mA
4.5 mA
2.8 mA
2.2 mA
R
2 mA
2.2 mA
2 mA
1.1 mA
0.9 mA
G
1.4 mA
1.6 mA
1.6 mA
1 mA
0.9 mA
Shock
Corrosion
Humidity
Mass
operating area IP40
terminal area IP00
with water splash cover IP54 or IP66
8 g (57-500 Hz), ± 0.61 mm (10-57 Hz)
test to IEC 60068-2-6, test Fc
10 frequency cycles/axis
30 g (11 ms)
test to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
test to IEC 60068-2-11, test Ka
240 hrs in 95 % RH
test to IEC 60068-2-78,
test Cab
approx. 33 g (2-pole)
approx. 27 g (1-pole)
approx. 42 g (2-pole with PT terminals)
1806
www.e-t-a.de
1
内核编程与驱动编程有什么不同?
“windows内核编程”和“windows驱动编程”这两个概念有什么不同,二者有没有重叠的地方。驱动程序是不是都是内核态下的程序??...
pikky 嵌入式系统
求最便宜的单片机
最便宜的单片机方案开发,产品是小家电类,量非常大(你一点会有兴趣的),需原厂家,代理的勿扰,谢谢!...
anming 单片机
刚入手launchpad MSP430FR6989 简单介绍下~
210594210595 前几天刚入手了这块板子 还不怎么会玩 简单介绍下~ ...
444368257 微控制器 MCU
2018年1月版主芯币及实物礼品奖励公告
大家好,按照最新的奖励细则对辛苦付出的版主们给予奖励。 版主福利>>>EEWORLD版主奖励细则 2018年1月获得奖励版主名单如下: 344193 请获得实物奖励的版主在一周内跟帖确认个人资料中的 ......
eric_wang 为我们提建议&公告
请教AD7528数模转换芯片的使用方法
请教AD7528数模转换芯片的使用方法...
STORMc 分立器件
XP下,并口可以实现0.1ms精度的外部触发吗?
我打算通过将外部信号连接到并口某根线上,当检测到上升沿/下降沿时,调用另外的驱动(别的厂商)进行动作。 1,可行吗? 2,上升沿响应精度可以达到0.1ms吗? 3,以什么方式检测到上升沿呢? ......
86682049 嵌入式系统

 
EEWorld订阅号

 
EEWorld服务号

 
汽车开发圈

 
机器人开发圈

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程 索引文件: 1362  1555  227  2339  2773  56  10  2  20  50 

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区中关村大街18号B座15层1530室 电话:(010)82350740 邮编:100190

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved