SA2-3600-DK1B-STD

产品描述Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 3600volts 1pF BENT KINKED LEADS
产品类别无线/射频/通信    电信电路   
文件大小335KB,共4页
制造商Bourns
官网地址http://www.bourns.com
标准
下载文档 详细参数 全文预览

SA2-3600-DK1B-STD在线购买

供应商 器件名称 价格 最低购买 库存  
SA2-3600-DK1B-STD - - 点击查看 点击购买

SA2-3600-DK1B-STD概述

Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 3600volts 1pF BENT KINKED LEADS

SA2-3600-DK1B-STD规格参数

参数名称属性值
是否Rohs认证符合
厂商名称Bourns
包装说明,
Reach Compliance Codecompliant
JESD-30 代码O-XDSS-T2
JESD-609代码e3
功能数量1
端子数量2
最高工作温度125 °C
最低工作温度-40 °C
封装主体材料UNSPECIFIED
封装形状ROUND
封装形式SPECIAL SHAPE
峰值回流温度(摄氏度)NOT SPECIFIED
表面贴装NO
电信集成电路类型SURGE PROTECTION CIRCUIT
温度等级AUTOMOTIVE
端子面层Matte Tin (Sn)
端子形式THROUGH-HOLE
端子位置DUAL
处于峰值回流温度下的最长时间NOT SPECIFIED
Base Number Matches1

文档预览

下载PDF文档
PL
IA
NT
Features
Formerly a
High insulation resistance
Quick response, long service life
Available DC breakdown range:
Applications
product
Street lighting
Medical devices
Air conditioning
Power supplies
Projectors
Welders
*R
oH
S
CO
M
2.4 kV to 7.2 kV
Wide operating temperature range
RoHS compliant*
SA2 Series High Voltage Gas Discharge Tube
Description
Bourns
®
SA2 Series two-electrode High Voltage Gas Discharge Tube devices are designed
for high isolation applications. The series offers high insulation resistance over a wide
temperature range and is offered with DC breakdowns from 2.4 kV to 7.2 kV. Other
customized voltages between 2 kV and 7.2 kV are available upon request.
Agency Recognition
Agency
UL
Category
UL 1449
Agency
File No.
E313168
Electrical Characteristics
Device Specifications
DC Breakdown Voltage
@ 500 V/s
Min.
Typ.
Max.
Tol.
Impulse
Breakdown
Max.
Ramp
Insulation
Resistance
@ 250 Vdc
Min.
Arc
Voltage
@ 5A
min.
Typ.
Capacitance
@ 1 MHz
Max.
Life Ratings
Nominal Impulse
Discharge
1
Operation
10
Operations
Nom.
DC
Break-
down
After
Life
Part No.
Typ.
SA2-2400-Dxx-STD
SA2-2400-Cxx-STD
SA2-3000-Dxx-STD
SA2-3000-Cxx-STD
SA2-3600-Dxx-STD
SA2-3600-Cxx-STD
SA2-5500-Dxx-STD
SA2-5500-Cxx-STD
SA2-6200-Dxx-STD
SA2-6200-Cxx-STD
SA2-6300-Dxx-STD
SA2-6300-Cxx-STD
SA2-7200-Dxx-STD
SA2-7200-Cxx-STD
2040
1920
2550
2400
3060
2880
4675
4400
5270
4960
5355
5040
6120
5760
2400
2400
3000
3000
3600
3600
5500
5500
6200
6200
6300
6300
7200
7200
2880
2880
3600
3600
4320
4320
6600
6600
7440
7440
7560
7560
8640
8640
-15 % to
+20 %
-20 % to
+20 %
-15 % to
+20 %
-20 % to
+20 %
-15 % to
+20 %
-20 % to
+20 %
-15 % to
+20 %
-20 % to
+20 %
-15 % to
+20 %
-20 % to
+20 %
-15 % to
+20 %
-20 % to
+20 %
-15 % to
+20 %
-20 % to
+20 %
3800 V
@1
kV/µs
>2.0 kV
>1.9 kV
>2.4 kV
>2.3 kV
>3.0 kV
>2.8 kV
5 kA,
8/20 µs, >4.4 kV
±5
operations >4.2 kV
in each
polarity
>5.2 kV
>4.9 kV
>5.3 kV
>5.0 kV
>6.3 kV
>6.0 kV
4500 V
@7.5
kV/µs
5400 V
@7.5
kV/µs
8000 V
@7.5
kV/µs
10 G Ohm
20 V
1 pF
10 kA,
8/20 µs
8000 V
@7.5
kV/µs
9200 V
@7.5
kV/µs
10000 V
@1
kV/µs
Note: Model SA2-7200 specification is based on the customer providing sufficient encapsulation/working environment for the component
to avoid outside surface breakdown (e.g., non-contaminated equivalent surface in RH 40 % reaches breakdown at 10-12 kV).
Product Characteristics
Operating Temperature Range .................................................................................................................................................... -40 °C to +125 °C
Storage Temperature Range ....................................................................................................................................................... -65 °C to +125 °C
Device Plating............................................................................................................................................................................................ Matte-Sn
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
申请TI的片子来了,怎么用大家给个意见吧
76390 430的单片机之前只是耳闻,还没用过,我51,EMC单片机会用,还有ARM9,ARM11会用。 现在要用这430还需要哪些工具和软件?? 本帖最后由 青叶漂零 于 2011-11-16 11:35 编辑 ]...
青叶漂零 DIY/开源硬件专区
全副sensor武装起来的自动小车
自动小车可以作为一个简易的探测机器人来使用。对于有些危险场合的信息收集很有意义,低成本和易用性是产品市场化的关键。...
lcdi 无线连接
发一本山海经,有兴趣的下
发一本山海经,有兴趣的下...
fing.yuan 聊聊、笑笑、闹闹
EasyARM-iMX283开发板串口信息
接上一篇帖子 EasyARM-iMX283开发板开箱上电 - 【ARM技术】 - 电子工程世界-论坛 https://bbs.eeworld.com.cn/thread-507683-1-1.html 开发板有1个232通信口,用USB-232通信线缆查看启动信 ......
suoma ARM技术
求RF4CE源码
TI网站上没找到。。。跪求。。...
will_hunting 无线连接
为什么集成电路IC需要自己的去耦电容?
为了保证高频输入和输出,每个集成电路(IC)都必须使用电容将各电源引脚连接到器件上的地,原因有二:防止噪声影响其本身的性能以及防止它传输噪声而影响其它电路的性能。 电力线就像天线一 ......
fish001 模拟与混合信号

 
EEWorld订阅号

 
EEWorld服务号

 
汽车开发圈

 
机器人开发圈

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程 索引文件: 2145  198  1395  1350  683  54  58  13  46  51 

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区中关村大街18号B座15层1530室 电话:(010)82350740 邮编:100190

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved