Thermal (T- and TA-Line)
https://www.schurter.com /PG17_20
T13-212
Circuit Breaker for Equipment thermal, Threaded neck type, Reset type, Screw terminals
Approvals and Compliances
Description
-
-
-
-
-
-
-
-
-
-
-
Threaded neck type
Thermal circuit breaker
1-pole
Reset type
Wide current range
High breaking capacity
Bolts and nuts
Compact design
Positively trip-free release
Available with cover
Different mounting possibilities
Applications
-
-
-
-
Power supplies
Uninterruptible power supply
Power tools
Household appliances
Weblinks
Unique Selling Proposition
pdf datasheet, html-datasheet, General Product Information, Distributor-
Stock-Check, Detailed request for product, Product News
Technical Data
Rated Voltage AC
Rated Voltage DC
Rated current range AC
Conditional short circuit ca-
pacity
Short circuit capacity Icn
␣
␣
Degree of Protection
Dielectric Strength
Insulation Resistance
Endurance typical
Endurance minimum
240/277 V; 50/60 Hz, see approbations
28 V
0.05 - 30 A
IEC: Inc, PC1, AC 240 V: 1 kA
at In < 7 A/240 VAC : 8 x In
at In
≥
7 A/240 VAC : 400 A
AC/DC 28 V : 400 A
from front side IP 40 acc. to IEC 60529
50 Hz: 1.5 kV
Impulse 1.2/50
μs:
> 2.5 kV
500 VDC > 100 MΩ
2 x Ir: 3000 switching cycles
Reset type
AC : 2 x Ir , cos
φ
0.6 :
DC : 2 x Ir , L/R = 2 - 3 ms :
50 switching cycles
Overload
␣
Ambient temperature
Vibration Resistance
IEC: min. 40 trips
@ 6 x Ir, cos
φ
0.6
UL / CSA: min. 50 trips
@ 1.5 x Ir, cos
φ
0.75
-5 °C to 60 °C
± 1.5 mm @ 10 - 60 Hz
acc. to IEC 60068-2-6, test Fc
10 G @ 60 - 500 Hz
acc. to IEC 60068-2-6, test Fc
100 G / 6 ms
acc. to IEC 60068-2-27, test Ea
Thermal
Reset type
ca. 10 g
Shock Resistance
Tripping Type
Actuation Type
Weight
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
Approvals
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: T13
Approval Logo
Certificates
VDE Approvals
UL Approvals
CSA Approvals
CQC Approvals
Certification Body
VDE
UL
CSA
CQC
Description
VDE Certificate Number:
UL File Number:
CSA Certification Record:
CCC File Number:
Circuit Breakers
1
T13-212
Application standards
Application standards where the product can be used
Organization
Design
Designed for applications acc.
Standard
IEC/UL 60950
Description
https://www.schurter.com /PG17_20
Thermal (T- and TA-Line)
IEC 60950-1 includes the basic requirements for the safety of information
technologyequipment.
Compliances
The product complies with following Guide Lines
Identification
Details
CE declaration of conformity
Initiator
SCHURTER AG
Description
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
EU Directive RoHS 2011/65/EU
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
RoHS
China RoHS
REACH
SCHURTER AG
SCHURTER AG
SCHURTER AG
Dimension [mm]
T13-212
1
2
3/8-27UNS-2A
Ø
13
Ø
5
8.8
20
16
6.
3
45
- 0.3
M4
20.4
31
- 0.0
+0.4
8
11.5
16
Ø
9
.6
8.9
+0.1
-0.0
2
Circuit Breakers
11.5
- 0.2
T13-212
Typical internal resistance
Rated Current [A]
0.05
0.50
1.00
2.00
3.00
4.00
5.00
6.00
8.00
9.00
10.00
11.00
12.00
13.00
14.00
15.00
16.00
17.00
18.00
19.00
20.00
21.00
22.00
23.00
24.00
25.00
26.00
27.00
28.00
29.00
30.00
Internal Resistance [Ω]
376.500
4.40
1.10
0.31
0.14
0.068
0.048
0.033
0.026
0.0125
0.0125
0.0085
0.0085
0.0085
0.007
0.007
0.007
0.0047
0.0047
0.0047
0.004
0.0035
0.003
0.003
0.003
0.003
0.0022
0.002
0.002
0.002
0.002
https://www.schurter.com /PG17_20
Thermal (T- and TA-Line)
Effect of ambient temperature
The units are calibrated for an ambient temperature of +23°C. To determine the rated cur-
rent for a lower or higher ambient temperature, use a correction factor (typical value) from
the table below:
Ambient temperature [°C]
-5
0
10
23
30
40
50
60
Correction factor
0.88
0.90
0.95
1.00
1.05
1.10
1.18
1.26
Example: Rated current = 5 A; Environmental temperature = 40 °C; --> Correction factor =
1.1; Resulting current = 5.5 A --> Fount to next higher rated current: 6 A
4
Circuit Breakers
Thermal (T- and TA-Line)
https://www.schurter.com /PG17_20
T13-212
Time-Current-Curves
[ min ] [ sec]
10'000
< 7,0 A
60
30
20
10
5
200
2`000
1`000
500
>
7,0A
Time in Seconds
100
1
50
20
10
5
2
1
0,5
0, 3
0, 2
0,1
1,05 1,32
2
3
4
5
8
10
Multiple of Rated Current In
Reference Temperature +23°
Config. Code
T13
|
-
|
1
|
2
|
3
|
B
|
-
|
1.23
|
The characters are placeholders for the correspondingly keys of selections from the key tables.
T13
|
-
|
1
|
2
|
3
|
B
|
-
|
1.23
|
= Mounting
Mounting
Threaded neck type with knurled nut
Configuration
key
2
Rated current
0.05 A
0.1 A
0.15 A
0.2 A
0.3 A
Configuration
key
1
0.4 A
0.5 A
0.6 A
0.7 A
0.8 A
0.9 A
Configuration
key
2
1.0
1.1 A
1.2 A
1.3 A
1.4 A
1.5 A
Configuration
key
R
1.6 A
1.7 A
1.8 A
1.9 A
2.0 A
2.1 A
2.3 A
Other rated currents on request
Configuration
key
0.05
0.1
0.15
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
2
2.1
2.3
T13
|
-
|
1
|
2
|
3
|
B
|
-
|
1.23
|
= Actuation Type
Actuation Type
Reset type
T13
|
-
|
1
|
2
|
3
|
B
|
-
|
1.23
|
= Terminal
Terminal
Screw clamp terminals
T13
|
-
|
1
|
2
|
3
|
B
|
-
|
1.23
|
= Setting indication
Setting indication
Setting indication
T13
|
-
|
1
|
2
|
3
|
B
|
-
|
1.23
|
= Rated current
Circuit Breakers
5