电子工程世界电子工程世界电子工程世界

关键词

搜索

型号

搜索

2035-20-B5

产品描述Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Sparkover100V/s 200V Miniature 2 Pole
产品类别无线/射频/通信    电信电路   
文件大小366KB,共2页
制造商Bourns
官网地址http://www.bourns.com
下载文档 详细参数 全文预览

2035-20-B5在线购买

供应商 器件名称 价格 最低购买 库存  
2035-20-B5 - - 点击查看 点击购买

2035-20-B5概述

Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Sparkover100V/s 200V Miniature 2 Pole

2035-20-B5规格参数

参数名称属性值
Reach Compliance Codeunknown
Factory Lead Time5 weeks
电信集成电路类型SURGE PROTECTION CIRCUIT
Base Number Matches1

文档预览

下载PDF文档
*R
oH
VE S CO
AV R M
AI SIO PL
LA N IA
BL S NT
E
Features
n
5 mm diameter, 4 mm long (2035 series)
n
5 mm diameter, 5 mm long (2037 series)
n
UL Recognized
n
High surge current rating
n
Stable breakdown throughout life
n
RoHS compliant* versions available
M
PL
IA
NT
Applications
n
Telecommunications
n
Industrial electronics
n
Commercial electronics
n
Consumer electronics
n
Automotive, aircraft, military electronics
Characteristics
LE
AD
F
RE
E
Test Methods per ITU-T K.12, IEEE C62.31 and IEC 61643-311 GDT standards.
Characteristic
DC Sparkover ±15 %
Impulse Sparkover
(1)
100 V/µs
1000 V/µs
Characteristic
DC Sparkover ±15 % @ 100 V/s
Impulse Sparkover
(1)
100 V/µs
1000 V/µs
(1)
*R
oH
S
CO
2035/2037 Series - Miniature 2-Pole Gas Discharge Tube
2035-2037-09
2035/2037-15
2035/2037-20
Model No.
2035/2037-23
2035/2037-25
2035/2037-30
(±20 % for Model 2035/2037-09) @ 100 V/s
90 V
300 V
550 V
150 V
Ro VE LEA
HS RS D
C ION FRE
OM S E
PL AR
IA E
NT
*
200 V
425 V
575 V
230 V
450 V
600 V
2035/2037-42
250 V
475 V
625 V
2035/2037-47
300V
525 V
650 V
2035/2037-60
350 V
550 V
2035/2037-35
350 V
600 V
750 V
2035/2037-40
Model No.
420 V
675 V
850 V
400 V
650 V
800 V
470 V
750 V
950 V
600 V
950 V
1100 V
Impulse Sparkover voltage is defined as typical values of distribution.
Insulation Resistance (IR) ..................100 V (50 V for Models 2035/2037-09) .................................. > 10
10
Ω
Glow Voltage ......................................10 mA ..................................................................................... ~ 70 V
Arc Voltage .........................................1 A .......................................................................................... ~ 10 V
Glow-Arc Transition Current ............................................................................................................... < 0.5 A
Capacitance........................................1 MHz ..................................................................................... < 1 pF
DC Holdover Voltage
(2)
.....................135 V, (52 V for Models 2035/2037-09, .................................. < 150 ms
80 V for Models 2035/2037-15)
Impulse Discharge Current ................10000 A, 8/20 µs
(3)
................................................................. 1 operation min.
5000 A, 8/20 µs ...................................................................... > 10 operations
1000 A, 10/350 µs .................................................................. 1 operation
100 A, 10/1000 µs ................................................................. > 300 operations
100 A, 10/700 µs ................................................................... > 500 operations
Alternating Discharge Current ...........20 Arms, 11 cycles
(3)
.............................................................. 1 operation min.
5 Arms, 1 s ............................................................................. > 10 operations
Operating Temperature ...................................................................................................................... -55 to +85 °C
Climatic Category (IEC 60068-1)........................................................................................................ 40/90/21
Notes:
• UL recognized component, UL File E153537.
• Model number marking on tube: xxxV.
• Sparkover limits after life ±20 % (-25 %, +30 % for Models 2035/2037-09 and 2035/2037-60) , IR>10
8
Ω.
• Other DC sparkover ranges available on request.
• At delivery AQL 0.65 Level II, DIN ISO 2859.
(2)
(3)
Network applied.
DC Sparkover may exceed ±20 % but will continue to protect without venting.
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.

技术资料推荐更多

 
EEWorld订阅号

 
EEWorld服务号

 
汽车开发圈

 
机器人开发圈

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程 索引文件: 1656  2030  2344  86  393  32  6  2  40  49 

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区中关村大街18号B座15层1530室 电话:(010)82350740 邮编:100190

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved