https://www.phoenixcontact.com/hq/products/2904586
Solid-state relay module - PLC-OPT-125DC/ 48DC/100 - 2904586
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
PLC-INTERFACE, consisting of PLC-BPT.../21 basic terminal block with push-in connection and plug-in
miniature solid-state relay, for mounting on DIN rail NS 35/7,5, 1 N/O contact, input: 125 V DC, output: 3 - 48
V DC/100 mA
The illustration shows the 24 V
version.
Key Commercial Data
Packing unit
GTIN
GTIN
Custom tariff number
Note
4046356865678
85364900
Made to Order (non-returnable)
10 STK
Technical data
Note
Utilization restriction
EMC: class A product, see manufacturer's declaration in the download
area
Dimensions
Width
Height
Depth
6.2 mm
80 mm
94 mm
Ambient conditions
Ambient temperature (operation)
Ambient temperature (storage/transport)
-25 °C ... 60 °C
-25 °C ... 70 °C
Input data
Nominal input voltage U
N
Input voltage range in reference to U
N
Input voltage range
125 V DC
0.8 ... 1.1
100 V DC ... 137.5 V DC
11/15/2016 Page 1 / 3
https://www.phoenixcontact.com/hq/products/2904586
Solid-state relay module - PLC-OPT-125DC/ 48DC/100 - 2904586
Technical data
Input data
Switching threshold "0" signal in reference to U
N
Switching threshold "1" signal in reference to U
N
Typical input current at U
N
Typical response time
Typical turn-off time
Status display
Transmission frequency
≤ 0.4
≥ 0.8
3 mA
1 ms (at U
N
)
3 ms (at U
N
)
Yellow LED
50 Hz
Output data
Output voltage range
Limiting continuous current
Voltage drop at max. limiting continuous current
Output circuit
Type of protection
Protective circuit/component
3 V DC ... 48 V DC
100 mA
≤1V
2-wire, floating
Reverse polarity protection
Surge protection
Polarity protection diode
Connection data, input side
Connection name
Connection method
Stripping length
Conductor cross section solid
Conductor cross section flexible
Conductor cross section AWG
Input side
Push-in connection
8 mm
0.14 mm² ... 2.5 mm²
0.14 mm² ... 2.5 mm²
26 ... 14
Connection data, output side
Connection name
Connection method
Stripping length
Conductor cross section solid
Conductor cross section flexible
Conductor cross section AWG
Output side
Push-in connection
8 mm
0.14 mm² ... 2.5 mm²
0.14 mm² ... 2.5 mm²
26 ... 14
General
Test voltage input/output
Mounting position
Assembly instructions
Operating mode
Flammability rating according to UL 94
Designation
Standards/regulations
2.5 kV (50 Hz, 1 min.)
any
In rows with zero spacing
100% operating factor
V0
Standards/regulations
IEC 60664
EN 50178
IEC 62103
11/15/2016 Page 2 / 3
https://www.phoenixcontact.com/hq/products/2904586
Solid-state relay module - PLC-OPT-125DC/ 48DC/100 - 2904586
Technical data
General
Rated surge voltage/insulation
Degree of pollution
Overvoltage category
Basic insulation
2
III
Standards and Regulations
Designation
Standards/regulations
Standards/regulations
IEC 60664
EN 50178
IEC 62103
Rated surge voltage/insulation
Degree of pollution
Overvoltage category
Flammability rating according to UL 94
Basic insulation
2
III
V0
Environmental Product Compliance
China RoHS
Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”,
Category “Manufacturer's declaration”
Drawings
Circuit diagram
A2
A1
13+
14
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
11/15/2016 Page 3 / 3