Millenium 3 Custom
➜
Sandwich communication extensions for XD10/XB10 and XD26/XB26
■
■
■
■
Exchange of input/output state with FBD programming
Only compatible with Custom controllers
Periodic exchanges with max. 6 XN06 extensions
Automatic recognition of number of slaves
Part numbers
Type
XN07
Description
6-word "exchange unit" communication extension
Supply
Via the 24 V
c
controller
Référence
88974250
Accessories
Designation
RJ45 tee-joint with 20 cm cable
EOL ferrules, RC 120
Ω
1 nF (pack of 2)
RJ45 wiring kit (2 tees, 2 ferrules, 1 x 4-pair FTP cable, 3 m)
Référence
88970125
88970126
88970127
"Exchange unit" characteristics
General characteristics
Certifications
Earthing
Operating temperature
Cable length
Pull-up and Pull-down resistance
UL, cUL pending
Internal link between electronic mass and equipment mass
Refer to the quick reference guide supplied with the product
-20
➞
+55 °C (+40 °C in a non-ventilated enclosure) in accordance with to IEC/EN
60068-2-1 and IEC/EN 60068-2-2
Maximum network length: 1000 m
(max. 9600 bauds, AWG 26)
Polarised line with 470
Ω
resistance (included in product)
Communication parameters
Type of link
Transmission rate (Bauds)
Parity
Addressing
2 or 4-wire; RTU or ASCII
1200, 2400, 4800, 9600, 19200, 28800, 38400, 57600
None; even; odd
XN07: 7
➞
247
XN06: 1
➞
6
1
Characteristics of exchanges
Function blocks programming
Read-words
Write-words
"Status" words
Clock synchronise bit
Initialisation bit
Watch dog bit
Cycle time
1 to 6, depending on the number of XN06 (1 XN06: 6 words, 2 XN06: 3 words, 3
XN06: 2 words, 4, 5 or 6 XN06: 1 word)
1 to 6, depending on the number of XN06 (1 XN06: 6 words, 2 XN06: 3 words, 3
XN06: 2 words, 4, 5 or 6 XN06: 1 word)
1 (state of XN06, connected - non-connected)
Date and time update bit XN07
➞
XN06
Initialisation bit (update of number of slaves connected)
1 per XN06 (0/1 if connected)
RTU
at 1200 bauds: with 6 XN06: < 3.7 s
at 1200 bauds: with 1 XN06: < 1 s
at 57600 bauds: with 6 XN06: < 0.2 s
ASCII
at 1200 bauds: with 6 XN06: < 5.7 s
at 1200 bauds: with 1 XN06: < 1.5 s
at 57600 bauds: with 6 XN06: < 0.2 s
Dimensions (mm)
XN07
57,5
52,5
27,5
88870126
11,7
15
10
35
100
27,5
15
44
88970125
20
200
53
108
35
90
39
35
20
42
2
Connections
Example with three slaves and accessories (two-wire)
XN07
88974250
88970125
1
88970126
88970126
88970125
2
XN06
88972250
3
XN06
88972250
4
XN06
88972250
B
RJ45/RJ45 "Cat 5E" - 100
Ω
FTP, 4 pairs (available in RJ45 wiring kit - part no.: 88970127)
C
XN06 Modbus slave 1
D
XN06 Modbus slave 2
E
XN06 Modbus slave 3
For the wiring rules refer to quick reference guide ISO876.
Applications
Increase the number of inputs/outputs
- More inputs/outputs while retaining the user-friendliness of Millenium 3
- Easier wiring over long distances (up to 1000 m)
- Flexible, modular solution
Double the processing capacity with data exchange
- Local and/or remote data processing
3