Techcon Systems
TS5000DMP Series
Disposable Material Path
Rotary Auger Valve
User Guide
CONTENTS
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
Page number
Specifications…………………………………………………………………3
Unpacking and Inspection…………………………………………………….4
Description...…………………………………………………….….………...4
Theory of Operation…………………………………………….….…………5
Set-Up Instructions……………………….…………………….….…………6
Typical Set-Up…………...…………………………………….…………..…7
Determining Dispensing Output……………………………………………8-9
DMP Removal/Replacement…………….……………………….…….…….9
Spare Parts…………………………………………………………………...10
DMP Insert Options.………………………..………….…….………….......11
Accessories………..………………………..………….…….….……….......11
Trouble Shooting………..………………………..………….…….………...12
Warranty……………………………………………………………………..13
2
1.
SPECIFICATIONS
TS5000DMP
Size
Weight
Fluid Inlet
Port
Fluid
Outlet Port
Maximum
Fluid
Pressure
Operating
Frequency
Mounting
Wetted
Parts
Viscosity
Range
5.88'' Length X 3.56''
(149.35mm X 90.42mm)
0.77 lb (350g)
Female Luer lock
Male Luer Lock
30 psi (2bar)
TS5000DMPL
5.88'' Length X 3.56''
(149.35mm X 90.42mm)
0.77 lb (350g)
Female Luer lock
Male Luer Lock
30 psi (2bar)
Exceeds 300 cycles/min.
Exceeds 300 cycles/min.
1'' (25.4mm) Channel
1'' (25.4mm) Channel
Delrin®, Nylon, Viton®
Delrin®, Nylon, Viton®
30,000cps – 1,300,000cps
30,000cps – 1,300,000cps
NOTE:
TS5000DMP = Right Hand Side Door Opening
TS5000DMPL = Left Hand Side Door Opening
Encoder DMP Options
Techcon Systems can offer the TS5000DMP with an encoder fitted to the DC
motor. This configuration is available with a right hand side door opening. Due to
machine integration restrictions the encoder option is available with the flexibility
of 3 encoder positions:
PART NUMBER
TS5000DMPE
TS5000DMPE-0
TS5000DMPE-15
DESCRIPTION
DMP Valve With 105° Encoder position
DMP Valve With 0° Encoder position
DMP Valve With 15° Encoder position
For spare parts, technical drawings, dimensional drawings, wiring diagrams or
encoder information, relating to the encoder valve option, please contact Techcon
Systems.
3
2.
UNPACKING AND INSPECTION
Carefully unpack the valve and examine the items contained in the carton.
These will include:
•
Valve assembly
•
Valve bracket and syringe bracket
•
Sample syringe kit and tip kit
•
Sample DMP feed screw/chamber (1 each of 6, 8 and 16-pitch)
•
User guide
Inspect the unit for any damaged which may have occurred in transit. If such
damage has occurred, notify the carrier at once. Claim for damage must be made
by the consignee to the carrier, and should be reported to the manufacturer.
13.
LIMITED WARRANTY
Manufacturer warrants this product to the original purchaser for a period of one (1)
year from date of purchase to be free from defects in material and workmanship,
but not against damages by misuse, negligence, accident, faulty installations and
instructions. Manufacturer will repair or replace (at factory’s option), free of
charge, any component of the equipment thus found to be defective, on return of
the component, “PREPAID” to the factory during the warranty period. In no event
shall any liability or obligation of the Manufacturer arising from this warranty
exceed the purchase price of the equipment. This warranty is only valid if the
defective product is returned as a complete assembly without physical damage.
The Manufacturer’s liability, as stated herein, cannot be altered or enlarged except
by a written statement signed by an officer of the company. In no event shall the
Manufacturer be liable for consequential or incidental damages. A return
authorization is required from Techcon Systems prior to shipping a defective unit
to the factory.
Manufacturer reserves the right to make engineering product modifications
without notice.
All returns must be issued with a Returns Authorization number, prior to return.
Send warranty returns to:
Americas and Asia
OK International
Garden Grove Division
12151 Monarch Street
Garden Grove, Ca 92841
Europe
OK International
Eagle Close
Chandler’s Ford Ind Est
Eastleigh
Hampshire
SO53 4NF
United Kingdom
3.
DESCRIPTION
The TS5000DMP Series Rotary Microvalve takes a revolutionary unique approach
to solving some of the most difficult dispensing problems. Two-component fluids
present a significant dispensing challenge, and the possibility of destroying
precision valve components, upon premature curing. Highly abrasive fluids
eventually decrease accuracy that is followed by total valve failure. With the
patented Disposable Material Path (DMP) Rotary Microvalve from Techcon
Systems, those concerns are erased.
A precision molded feed screw and chamber is captured in a “clamshell” design
valve housing. Inexpensive disposable feed screw and chamber components may
be changed quickly and easily. Cleanup is reduced to simply changing out the
disposable material path. An inexpensive stock of disposable valve components
replaces an inventory of back up valves.
The accuracy of the TS5000DMP valve meets the needs of users previously
constrained to lower accuracy of time/pressure dispensing. It also meets the
maintenance cost targets of users previously relegated to recurring, maintenance of
non-disposable path valves. Current TS5000 Rotary Microvalve customers may
find the accuracy of the TS5000DMP valve meet their current accuracy
specifications.
www.techconsystems.com
Delrin®, Viton® and Teflon® are registered trademarks of E.I. DuPont.
T9000119_B
4
13
12. TROUBLE SHOOTING
PROBLEM
POSSIBLE CAUSE
Dispense tip is plugged
Motor does not receive signal
No Fluid Flow
Motor running in reverse
Syringe barrel of dispense fluid
is empty
Fluid feed pressure is too low
Feed screw damaged
CORRECTION
Replace tip
Make sure all connections are
secured
Reverse motor cable
connection
Replace with new syringe
barrel, of fluid
Increase feed pressure.
Replace with new feed
screw/chamber
Make sure fluid pressure is
constant
4.
THEORY OF OPERATION
(refer to figure 1.0)
The TS5000DMP Series Rotary Microvalve dispenses fluid with a positive
displacement action using a rotary feed screw principle. Fluid is held in a feed
reservoir (2), normally a syringe barrel or cartridge, under a positive head of air,
between 1 to 20 psi (0.07 to 1.38bar), depending upon the viscosity of the fluid.
The positive air pressure, supplied by the air line (1), forces the fluid out of the
syringe barrel (2) into the material feed path (3) then to the feed screw chamber
(5). Fluid flows from this point (5) to the dispense point (4) and is controlled by
the feed screw rotation in the feed direction. The feed screw is driven by the DC
motor (6). Applying a DC voltage signal to the DC motor (6), will rotate the feed
screw and the fluid will be forced out the dispense tip (4). The actual fluid
deposited is dependent upon adhesion of the dispensed fluid to the substrate.
Shearing of the fluid is achieved by reverse Z-motion (tip retraction). When the
motor stops, the unit remains in position for a fraction of a second (dwell) to allow
the last drop of fluid to flow out of the dispense tip. After the dwell period, the
automation equipment moves the TS5000DMP valve to the next position.
Fluid pressure fluctuating
Inconsistent
Fluid Flow
Valve on time is too short
Increase valve on time
Reduce reverse time or turn
off completely.
Excessive motor reverse time
Fluid drools after
the valve turned
off
Air trapped in fluid housing
Purge valve properly
Air trapped in feed screw
chamber
Air trapped in fluid reservoir
Dispense tip
clogged
Excessive fluid feed pressure
Purge valve properly
Remove air from reservoir
Reduce pressure or turn off
pressure when the valve is
idle.
Increase dispense height
Tip contacting substrate
Figure 1.0
12