OM1905NKM OM1915NKM
OM1912NKM
HERMETIC TO-3 FIXED VOLTAGE NEGATIVE
REGULATORS APPROVED TO DESC DRAWINGS
Three Terminal, Fixed Voltage, 1.5 Amp
Precision Negative Regulators In Hermetic
JEDEC TO-3 Package
FEATURES
•
•
•
•
•
•
Output Voltages: -5V, -12V, -15V
Output Voltages Set Internally to ±1%
Built-In Thermal Overload Protection
Short Circuit Current Limiting
Similar To Industry Standards 7905, 7912, 7915
Hi-Rel Screening Available
DESCRIPTION
These three terminal negative regulators are supplied in a hermetically sealed TO-3
metal package . All protective features are designed into the circuit, including thermal
shutdown, current limiting and safe-area control. With heat sinking, they can deliver
over 1.5 amps of output current. These units feature internally trimmed output
voltages to ±1% of nominal voltage. Standard voltages are -5V, -12V, -15V. These
units are ideally suited for Military applications where a hermetically sealed package
is required.
PART NUMBER DESIGNATOR
Standard Military Drawing Number
5962-8874601 YX
5962-8874701 YX
5962-8874801 YX
Omnirel Part Number
OM1905NKM
OM1912NKM
OM1915NKM
3.3
4 11 R0
3.3 - 87
OM1905NKM - OM1915NKM
ABSOLUTE MAXIMUM RATINGS @ 25°C
Input Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -35 V
Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . .- 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C
Typical Power/Thermal Charateristics:
Rated Power @ 25° C T
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20W
T
A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.6W
Thermal Resistance
q
JC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2°C/W
aa
q
JA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42°C/W
ELECTRICAL CHARACTERISTICS -5
Volt
Parameter
Output Voltage
Symbol
V
OUT
V
IN
= -10V, I
o
= 500mA, -55°C T
A
125°C (unless otherwise specified)
Min.
-4.95
Max.
-5.05
-5.15
Unit
V
V
Test Conditions
T
A
= 25°C
V
IN
= -7.5V to -20V
I
O
= 5mA to 1.0 A, P< 20W
•
-4.85
Line Regulation
(Note 1)
(Note 4)
V
RLINE
V
IN
= -7.5V to -20V
12
mV
mV
mV
mV
mV
mV
mV
mV
mA
mA
mA
•
V
IN
= -8.0V to -12V
25
5
•
Load Regulation
(Note 1)
I
O
= 250mA to 750 mA
V
RLOAD
I
O
= 5mA to 1.5 Amp
12
20
•
•
25
15
30
2.5
Standby Current Drain
I
SCD
DI
SCD
(Line)
DI
SCD
(Load)
V
DO
I
O (pk)
I
DS
DV
IN
DV
OUT
N
O
DV
OUT
Dt
DV
OUT
= 100mV, I
O
=
1.0A
T
A
= 25°C
V
IN
= -35V
I
O
= 5mA to 1000mA
V
IN
= -7.0V to -20V
Standby Current Drain
Change With Line
Standby Current Drain
Change With Load
Dropout Voltage
Peak Output Current
Short Circuit Current
(Note 2)
•
•
•
•
1.5
3.0
0.4
0.4
mA
2.5
3.3
1.2
V
A
A
A
dB
dB
•
f =120 Hz,
DV
IN
= -10V
(Note 3)
T
A
= 25°C, f =10 Hz to 100KHz
T
A
= 25°C, t = 1000 hrs.
63
2.8
3.3
Ripple Rejection
•
60
40
Output Noise Voltage
(Note 3)
Long Term Stability
(Note 3)
µV/V
RMS
75
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
IN
= -35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
3.3 - 88
OM1905NKM - OM1915NKM
ELECTRICAL CHARACTERISTICS -12 Volt
Parameter
Output Voltage
Symbol
V
OUT
V
IN
= -19V, I
o
= 500mA, -55°C T
A
125°C (unless otherwise specified)
Min.
-11.88
Max.
-12.12
-12.36
Unit
V
V
Test Conditions
T
A
= 25°C
V
IN
= -14.5V to -27V
I
O
= 5mA to 1.0 A, P
D
< 20W
•
-11.64
Line Regulation
(Note 1)
(Note 4)
V
RLINE
V
IN
= -14.5V to -27V
20
mV
mV
mV
mV
mV
mV
mV
mV
mA
mA
mA
•
V
IN
= -16V to -22V
50
10
•
Load Regulation
(Note 1)
I
O
= 250mA to 750 mA
V
RLOAD
I
O
= 5mA to 1.5 Amp
30
32
•
•
60
16
30
3.5
Standby Current Drain
I
SCD
DI
SCD
(Line)
DI
SCD
(Load)
V
DO
I
O (pk)
I
DS
DV
IN
DV
OUT
N
O
DV
OUT
Dt
DV
OUT
= 100mV, I
O
=
1.0A
T
A
= 25°C, I
O
= 5mA to 1A
V
IN
= -35V
I
O
= 5mA to 1000mA
V
IN
= -14.5V to -27V
Standby Current Drain
Change With Line
Standby Current Drain
Change With Load
Dropout Voltage
Peak Output Current
Short Circuit Current
(Note 2)
Ripple Rejection
•
•
•
•
1.5
4.0
0.8
0.5
mA
1.8
3.3
1.2
V
A
A
A
dB
dB
•
f =120 Hz,
DV
IN
= -10V
(Note 3)
T
A
= 25°C, f =10 Hz to 100KHz
T
A
= 25°C, t = 1000 hrs.
56
2.8
•
53
40
Output Noise Voltage
(Note 3)
Long Term Stability
(Note 3)
µV/V
RMS
120
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
IN
= -35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
MECHANICAL OUTLINE
1.53
REF.
0.875
MAX.
0.135
MAX.
0.450
0.250
0.312
MIN.
SEATING
PLANE
0.043
0.038
2 PLCS.
0.225
0.205
0.161
0.151
0.525 R.
MAX.
1.197
1.177
0.675
0.655
0.440
0.420
3.3
Pin Connection
Pin 1: Ground
Pin 2: Output
Case: Input
0.188 R.
MAX.
2
1
3.3 - 89
OM1905NKM - OM1915NKM
ELECTRICAL CHARACTERISTICS -15 Volt
Parameter
Output Voltage
Symbol
V
OUT
V
IN
= -23V, I
o
= 500mA, -55°C T
A
125°C (unless otherwise specified)
Min.
-14.85
Max.
-15.15
-15.45
Unit
V
V
Test Conditions
T
A
= 25°C
V
IN
= -17.5V to -30V
I
O
= 5 mA to 1.0 A, P
D
< 20 W
•
-14.55
Line Regulation
(Note 1)
(Note 4)
V
RLINE
V
IN
= -17.5V to -30V
25
mV
mV
mV
mV
mV
mV
mV
mV
mA
mA
mA
•
V
IN
= -20V to -26V
50
15
•
Load Regulation
(Note 1)
I
O
= 250mA to 750 mA
V
RLOAD
I
O
= 5mA to 1.5 Amp
25
35
•
•
75
21
45
6.0
Standby Current Drain
I
SCD
DI
SCD
(Line)
DI
SCD
(Load)
V
DO
I
O (pk)
I
DS
DV
IN
DV
OUT
N
O
DV
OUT
Dt
DV
OUT
= 100mV, I
O
=
1.0A
T
A
= 25°C
V
IN
= -35V
I
O
= 5mA to 1000mA
V
IN
= -17.5V to -30V
Standby Current Drain
Change With Line
Standby Current Drain
Change With Load
Dropout Voltage
Peak Output Current
Short Circuit Current
(Note 2)
Ripple Rejection
•
•
•
•
1.5
6.5
0.8
0.5
mA
2.5
3.3
1.2
V
A
A
A
dB
dB
•
f =120 Hz,
DV
IN
= -10V
(Note 3)
T
A
= 25°C, f =10 Hz to 100KHz
T
A
= 25°C, t = 1000 hrs.
53
2.8
•
50
40
Output Noise Voltage
(Note 3)
Long Term Stability
(Note 3)
µV/V
RMS
150
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
IN
= -35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
TYPICAL PERFORMANCE CHARACTERISTICS
3.3
PEAK OUTPUT CURRENT
3.5
3
2.5
T
j
=
DROPOUT VOLTAGE
2.5
RIPPLE REJECTION
100
2
I
OUT
= 1A
80
V
OUT
= 5V
Output Current (A)
1.5
I
OUT
= 500mA
Ripple Rejection (dB)
Output Current (A)
2
T
j
= 25°C
60
1.5
1
T
j
= 150°C
1
I
OUT
= 0A
40
V
IN
- V = 8V
DC
+3.5V
rms
I
OUT
= 1A
T
j
= 25°C
0.5
DV
OUT
= 100MV
0.5
DV
OUT
= 100mV
20
0
0
5
10
15
20
25
30
35
0
-75 -50 -25
0
25 50 75 100 125 150
0
10
100
1k
10k
100k
205 Crawford
Frequency (Hz)
Input To Output Differential (V)
Street, Leominster, MA 01453 USA (508) 534-5776 FAX (508) 537-4246
Junction Temperature (°C)
205 Crawford Street, Leominster, MA 01453 USA (508) 534-5776 FAX (508) 537-4246