Power Supplies
DC to DC Converters
Single/Multi Output, General-Purpose
FEATURES
• These DC to DC converters are entirely shielded by a metal
case.
• No external components needed.
• Built-in short circuit protection.
TEMPERATURE AND HUMIDITY RANGES
Temperature Operating –10 to +70°C[With derating over 50°C]
range
Storage
–20 to +85°C
Humidity range
95(%)RH max.
[Maximum wet-bulb temperature:38°C]
CAP Series
DERATINGS
Derating is necessary when operating environment temperatures
exceed 50°C.
120
Output power (%)
100
80
60
40
20
0
0
10
20 30 40 50 60 70
Ambient temperature (°C)
80
SHAPES AND DIMENSIONS/CIRCUIT DIAGRAM
49.5max.
13.2max.
4min.
Vin
4
–Vout
+Vin
1
5
+Vout
R
L
TERMINAL CONNECTIONS
No.1
No.2
No.3
No.4
No.5
No.6, 7
No.8, 9
+Vin
–Vin
NC
–Vout
+Vout
Case GND
Stand-off
t=0.3
5-ø0.8±0.1
or 0.64±0.1(diagonal 0.85±0.1)
0.4
–Vin
2
3 NC
15.24 15.24
8
2
6
1
43.18
3
4
7
39.5max.
20
3
1.5
9
5
Weight: 42g
Dimensions in mm
Tolerance:
±0.3
ELECTRICAL CHARACTERISTICS
Part No.
Output
Input voltage
voltage
∗
1
Edc(V)
(V)
5±5%
12±5%
5±5%
12±5%
Output
current
(mA)
Output voltage stability(%) typ.
Load
1
1
1
1
Temperature
∗
4
0.01
0.01
0.01
0.01
Output ripple noise
voltage
∗
2
Ep-p(mV)
typ.
max.
50
100
50
100
50
100
50
100
Efficiency
∗
3
(%)typ.
78
78
78
78
Input-output
insulation
Withstand voltage
AC.500V 1min
Insulation
resistance
50M
Ω
min.
DC.500V
CAP-2405F 18 to 28
CAP-2412F 18 to 28
CAP-4805F 36 to 56
CAP-4812F 36 to 56
∗
1
∗
2
Input
0 to 1600 1
0 to 800 1
0 to 1600 1
0 to 800
1
Output voltage: input variation(18 to 28V or 36 to 56V), load variation: 0 to 100%, temperature variation: –10 to +70°C.
Measurement frequency: 50MHz
∗
3
Input voltage: typical value, output current: maximum value
∗
4
Variation value per 1°C
PRECAUTIONS
• Neither addition nor subtraction of output voltages are possible
by the combination of converter outputs. Please contact TDK to
discuss applications that require such voltage combinations.
• When a fuse is connected to the input to prevent smoke and fire,
etc. damage during abnormal events, this fuse should have a
current rating 3 to 8 times that of the rated(normal) input current.
• Caution is required when combining the converter output with
that of another power source(including the converter input power
source) for the operation of load circuitry. Please contact TDK to
discuss such applications.
• Since the converter is entirely shielded by a metal case, care
should be taken to isolate the case from the surrounding
components and wiring pattern.
• Although no specific cleaning requirements are provided for
post-solder flux cleaning, cleaning verification testing is
recommended if such flux cleaning is required. Please discuss
cleaning with TDK if results from such tests are unclear.
A337_CAP
980424
Specifications which provide more details for the proper and safe use of the described product are available upon request.
All specifications are subject to change without notice.