Wire Wound Chip Inductors
——E-Series
0402C(1005)/5524
Features
1. Coil body of ceramic material.
2. Rugged inductance even in high frequencies.
3. Tight tolerances.
4 .Low DC resistance.
5. Operating temperature range –40°C to +85°C
6. Lead Free (RoHS Compliance)
PAGE
1/3
Applications
1. Antenna amplifier.
2. Mobile phones (GSM etc.)
3. Global Positioning Systems (GPS)
4. Digital cameras.
5. HDD (Hard Disk Drivers) etc.
Ordering Information
5524
(1)
270
(2)
*
(3)
452
(1) Series
- 5524 Size 0402C(1005), Ceramic body
(3) Inductance Tolerance
2 : ±10%
3 : ±5%
4 : ±2%
(2) Inductance Value
example: 27x10
X
=27x10
0
=27(nH)
Shape and Dimensions (mm)
Pad Layout Recommendation
Electrode: Mo/Mn/Ni/Sn
*All specifications are subject to change without notice.
Wire Wound Chip Inductors
——E-Series
0402C(1005)/5524
Electrical Parameters
L
[nH]
5524 010 *4 52
5524 019 *4 52
5524 020 *4 52
5524 022 *4 52
5524 024 *4 52
5524 027 *4 52
5524 033 *4 52
5524 036 *4 52
5524 039 *4 52
5524 043 *4 52
5524 047 *4 52
5524 051 *4 52
5524 056 *4 52
5524 062 *4 52
5524 068 *4 52
5524 075 *4 52
5524 082 *4 52
5524 087 *4 52
5524 090 *4 52
5524 095 *4 52
5524 100 *4 52
5524 110 *4 52
5524 120 *4 52
5524 130 *4 52
5524 150 *4 52
5524 160 *4 52
5524 180 *4 52
5524 190 *4 52
5524 200 *4 52
5524 220 *4 52
5524 230 *4 52
5524 240 *4 52
5524 270 *4 52
5524 300 *4 52
5524 330 *4 52
5524 360 *4 52
5524 390 *4 52
5524 400 *4 52
5524 430 *4 52
5524 470 *4 52
5524 510 *4 52
5524 560 *4 52
5524 680 *4 52
5524 820 *4 52
5524 101 *4 52
5524 121 *4 52
1,0
1,9
2,0
2,2
2,4
2,7
3,3
3,6
3,9
4,3
4,7
5,1
5,6
6,2
6,8
7,5
8,2
8,7
9,0
9,5
10,0
11,0
12,0
13,0
15,0
16,0
18,0
19,0
20,0
22,0
23,0
24,0
27,0
30,0
33,0
36,0
39,0
40,0
43,0
47,0
51,0
56,0
68,0
82,0
100,0
120,0
16,0
16,0
16,0
19,0
15,0
16,0
19,0
19,0
19,0
18,0
15,0
20,0
20,0
20,0
20,0
22,0
22,0
18,0
22,0
18,0
21,0
24,0
24,0
24,0
24,0
24,0
24,0
24,0
25,0
25,0
22,0
25,0
24,0
25,0
24,0
24,0
25,0
24,0
25,0
20,0
22,0
22,0
22,0
20,0
20,0
20,0
PAGE
2/3
Order No.
Q
min
f
L, Q
[MHz]
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
Q
typ.
@ 900 MHz
35
45
45
46
41
40
47
54
56
47
45
51
57
54
53
56
56
55
57
54
53
54
57
55
57
55
57
55
54
55
55
54
55
54
51
50
52
52
52
52
52
53
52
51
30
20
f
res, min
[MHz]
12700
11300
11100
10800
10500
10400
7000
6800
6000
6000
4770
4800
4800
4800
4800
4800
4400
4100
4160
4000
3900
3680
3600
3450
3280
3100
3100
3040
3000
2800
2720
2700
2480
2350
2350
2320
2100
2240
2030
2100
1750
1760
1620
2000
1100
1000
D.C.R. max.
[
Ω
]
0,045
0,070
0,070
0,070
0,068
0,120
0,066
0,066
0,066
0,091
0,130
0,083
0,083
0,083
0,083
0,100
0,100
0,200
0,100
0,200
0,200
0,120
0,120
0,210
0,170
0,220
0,230
0,200
0,250
0,300
0,300
0,300
0,300
0,300
0,300
0,440
0,550
0,440
0,810
0,830
0,820
0,970
1,120
2,240
2,520
2,660
I
DC, max
[mA]
1360
1040
1040
960
790
640
840
840
840
700
640
800
760
760
680
680
680
480
680
480
480
640
640
440
560
560
420
480
420
400
400
400
400
400
400
320
200
320
100
150
100
100
100
100
120
110
Tol.
[%]
5/10
5/10
5/10
5/10
5/10
5/10
5/10
5/10
5/10
5/10
5/10
5/10
5/10
5/10
5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
2/5/10
5/10
5/10
5/10
※
Packing Unit: 3,000 pcs. each
*All specifications are subject to change without notice.
Wire Wound Chip Inductors
——E-Series
0402C(1005)/5524
Electrical Characteristic Curves
Typical Q vs. Frequency
80
70
60
50
Q Factor
40
30
20
10
0
1
10
100
Frequency (MHz)
1000
10000
1.0nH
27nH
12nH
19nH
5.6nH
PAGE
3/3
Typical L vs Frequency
60
27nH
50
Inductance (nH)
40
30
20
10
0
12nH
1.0nH
19nH
5.6nH
Test Equipment
1
10
100
Frequency (MHz)
1000
10000
Inductance and Quality Factor
RF LCR Meter: Agilent 4287 A
Test Fixture:
Agilent 16193 A or equivalent
Resonant Frequency
Network Analyzer: Agilent 8720 ES or equivalent
R
DC
Measured at 25 °C ambient temperature
Digital Multimeter: Agilent 34420A or equivalent
Max. Permissible Direct Current:At 25 °C ambient temperature permissible temperature rise:20 K