https://www.phoenixcontact.com/in/products/1425179
Network cable - NBC-MSD/25,2-939/MSD SCO SI - 1425179
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Network cable, PROFINET CAT5 (100 Mbps), 4-position, PE-X halogen-free, black, shielded, Plug straight
M12 SPEEDCON / IP65, cable length: 25.2 m, Product tested according to customer specification/rail
application
Key Commercial Data
Packing unit
GTIN
GTIN
Custom tariff number
4055626386553
85444290
1
Technical data
Dimensions
Length of cable
25.2 m
General data
Note
Rated current at 40°C
Rated voltage
Number of positions
Signal type/category
Standards/regulations
Overvoltage category
Degree of pollution
The cable is 100% electrically tested for continuity.
4A
48 V AC
60 V DC
4
PROFINET CAT5 (IEC 11801), 100 Mbps
M12 connector IEC 61076-2-101
II
3
Characteristics head 1
Head type
No. of positions (pin connector pattern)
Color
Material (component)
Plug straight M12 SPEEDCON / IP65
4
black
CuSn (Contact)
01/06/2019 Page 1 / 5
https://www.phoenixcontact.com/in/products/1425179
Network cable - NBC-MSD/25,2-939/MSD SCO SI - 1425179
Technical data
Characteristics head 1
Ni/Au (Contact surface)
PA (Contact carriers)
TPU, hardly inflammable, self-extinguishing (Grip)
Zinc die-cast, nickel-plated (Screw connection)
Shielded
yes
Standards and Regulations
Standard designation
Standards/regulations
Flammability rating according to UL 94
M12 connector
IEC 61076-2-101
V0
Cable
Cable type
Cable type (abbreviation)
Signal type/category
Cable structure
Conductor cross section
AWG signal line
Conductor structure signal line
Core diameter including insulation
Wire colors
Overall twist
Shielding
External sheath, color
Outer sheath thickness
External cable diameter D
Minimum bending radius, fixed installation
Minimum bending radius, flexible installation
Tensile strength GRP
Cable weight
Outer sheath, material
Material conductor insulation
Conductor material
Insulation resistance
Conductor resistance
Cable capacity
Wave impedance
Near end crosstalk attenuation (NEXT)
PROFINET railway applications
939
PROFINET CAT5 (IEC 11801), 100 Mbps
1x4xAWG22/7; SF/TQ
4x 0.34 mm²
22
7x 0.25 mm
1.4 mm ±0.1 mm
white-blue, orange-yellow
Star quad
Aluminum-lined polyester foil, tinned copper braided shield
black
1 mm
6.6 mm ±0.2 mm
5xD
6xD
≤ 60 N (temporary)
≤ 15 N (Permanent)
71 kg/km
PE-X
Cell PE
Tin-plated Cu litz wires
≥ 5 GΩ*km
≤ 54.4 Ω/km
44 nF/km (core-core)
100 Ω ±5 Ω (f = 100 MHz)
76 dB (with 1 MHz)
71 dB (at 4 МHz)
64 dB (at 10 MHz)
60 dB (at 16 MHz)
01/06/2019 Page 2 / 5
https://www.phoenixcontact.com/in/products/1425179
Network cable - NBC-MSD/25,2-939/MSD SCO SI - 1425179
Technical data
Cable
56 dB (at 31.25 МHz)
52 dB (at 62.5 МHz)
48 dB (at 100 MHz)
45 dB (at 155 MHz)
42 dB (at 200 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)
73 dB (with 1 MHz)
68 dB (at 4 МHz)
61 dB (at 10 MHz)
57 dB (at 16 MHz)
53 dB (at 31.25 МHz)
49 dB (at 62.5 МHz)
45 dB (at 100 MHz)
42 dB (at 155 MHz)
39 dB (at 200 MHz)
Attenuation
1.5 dB (with 1 MHz)
3.3 dB (at 4 МHz)
5.3 dB (at 10 MHz)
6.9 dB (at 16 MHz)
9.9 dB (at 31.25 МHz)
14.5 dB (at 62.5 МHz)
18.8 dB (at 100 MHz)
23.6 dB (at 155 MHz)
27.3 dB (at 200 MHz)
Return loss (RL)
25 dB (with 1 MHz)
25 dB (at 4 МHz)
28 dB (at 10 MHz)
28 dB (at 16 MHz)
27 dB (at 31.25 МHz)
26 dB (at 62.5 МHz)
25 dB (at 100 MHz)
25 dB (at 155 MHz)
23 dB (at 200 MHz)
Signal speed
Signal runtime
Shield attenuation
Coupling resistance
Cable impedance
Nominal voltage, cable
Test voltage Core/Core
0.75 c
4.4 ns/m
60 dB (up to 1000 MHz)
< 13.00 mΩ/m (f = 1 MHz)
< 8.00 mΩ/m (f = 10 MHz ... 100 MHz)
100 Ω ±15 Ω (f = 0.5 MHz ... 3 MHz)
125 V
1000 V AC (50 Hz, 1 min.)
01/06/2019 Page 3 / 5
https://www.phoenixcontact.com/in/products/1425179
Network cable - NBC-MSD/25,2-939/MSD SCO SI - 1425179
Technical data
Cable
Test voltage Core/Shield
Fire protection in rail vehicles
1000 V AC (50 Hz, 1 min.)
BS 6853 (Internal cable Ia, Ib, II/external cable Ia, Ib, II)
DIN 5510-2 (Fire protection level 1, 2, 3, 4)
EN 45545-2 (Risk level HL1 - HL3)
EN 50306-4
NF F16-101 (Classification C/F1)
NF F16-101 (Internal cable A1, A2, B/external cable A1, A2, B)
NFPA 130
PN-K-02511
UIC 564-2 (Class A)
Flame resistance
according to EN 60332-1-2
according to EN 50266-2-5
according to ISO 14572 5.21 (UN ECE-R 118.01)
Halogen-free
Resistance to oil
Other resistance
According to EN 50267-2-1
according to EN 60684-2
according to EN 60684-2, 72 h at 100 °C, IRM 902
Resistant to fuel according to EN 60684-2, 72 h at 100 °C, IRM 903
Resistant to ozone according to EN 50306-4, 72 h at 40 °C, procedure
-6
B, volume concentration 200 x 10
Concentration of fumes
Ambient temperature (operation)
EN 61034-2
-40 °C ... 85 °C (cable, fixed installation)
-25 °C ... 70 °C (cable, flexible installation)
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Drawings
Schematic diagram
Cable cross section
Pin assignment M12 male connector, 4-pos., D-coded, male side
PROFINET railway applications [939]
01/06/2019 Page 4 / 5
https://www.phoenixcontact.com/in/products/1425179
Network cable - NBC-MSD/25,2-939/MSD SCO SI - 1425179
Circuit diagram
Dimensional drawing
1
2
3
4
1 YE
2 WH
47,3
Ø14,8
M12
3 OG
4 BU
Contact assignment of the M12 plugs
M12 SPEEDCON plug, straight, shielded
Classifications
eCl@ss
eCl@ss 7.0
eCl@ss 9.0
27060308
27060308
Phoenix Contact 2019 © - all rights reserved
http://www.phoenixcontact.com
01/06/2019 Page 5 / 5
Ø12