INT ERNET DAT A SHEET for Article Number 7000-13261-3313200
M12 FEMALE 90° SHIELDED
PUR 4X0.34 shielded GRAY, 32m
Female 90°
M12, 4-pole
shielded
with cable sleeves
Plastic housings with good resistance against chemicals and oils. The resistance to
aggressive media should be individually tested for your application. Further details on
request. Further cable lengths on request.
Link t o Product
Illustra tio n
The info rmatio n in this b ro c hure has b e e n c o mp ile d with the utmo s t c are .
Liab ility fo r the c o rre c tne s s c o mp le te ne s s and to p ic ality o f the info rmatio n is re s tric te d to g ro s s ne g lig e nc e . Ve rs io n: 02/19
Mu r r e l e ktr o n i k G m b H | Fa l ke n s tr a ße 3 | 71570 O p p e n we i l e r | Fo n +49 ( 71 91) 47-0 | Fa x +49 ( 71 91) 47-491000 | s h o p @ m u r r e l e ktr o n i k.co m |
s h o p .m u r r e l e ktr o n i k.co m
INT ERNET DAT A SHEET for Article Number 7000-13261-3313200
Pro d uc t may d iffe r fro m Imag e
Appro va ls
* only for products with UL/CSA approved cable
cCSAus
Fo rm
Fo rm
Ca bles
Cab le numb er
No ./d iameter o f wires
Wire iso latio n
Jacket Co lo r
Material (jacket)
Outer Ø
Bend rad ius (fixed )
331
4 × 0.34 mm²
PVC (b r, wh, b l, b k)
g ray
PUR/PVC
5.9 mm ±5%
10 × o uter Ø
13261
The info rmatio n in this b ro c hure has b e e n c o mp ile d with the utmo s t c are .
Liab ility fo r the c o rre c tne s s c o mp le te ne s s and to p ic ality o f the info rmatio n is re s tric te d to g ro s s ne g lig e nc e . Ve rs io n: 02/19
Mu r r e l e ktr o n i k G m b H | Fa l ke n s tr a ße 3 | 71570 O p p e n we i l e r | Fo n +49 ( 71 91) 47-0 | Fa x +49 ( 71 91) 47-491000 | s h o p @ m u r r e l e ktr o n i k.co m |
s h o p .m u r r e l e ktr o n i k.co m
INT ERNET DAT A SHEET for Article Number 7000-13261-3313200
Bend rad ius (mo ving )
T emp erature rang e (fixed )
T emp erature rang e (mo b ile)
Shield
Co lo r (jacket)
T ec hnic a l da ta
Op erating vo ltag e
Op erating vo ltag e (o nly UL listed )
Op erating current p er co ntact
Rated surg e vo ltag e
Material g ro up
Co d ing
Lo cking o f p o rts
Co mp ressio n g land
Pro tectio n
Lo cking material
Material
Genera l da ta
Stand ard s
Po llutio n Deg ree
T emp erature rang e
Co m m erc ia l da ta
co untry o f o rig in
custo ms tariff numb er
EAN
eClass
Packag ing unit
15 × o uter Ø
-30...+80 °C
-5...+70 °C
yes
g ray
max. 60 V AC/DC
max. 30 V AC/DC
max. 4 A
1.5 kV
IEC 60664-1, categ o ry I
A-co d ed
Screw thread M12 × 1 mm (reco mmend ed to rq ue 0.6 Nm) self-
securing
M12 (SW13)
IP65, IP66K, IP67 inserted and tig htened (EN 60529)
Zinc d ie casting , matte nickel p lated
PUR
DIN EN 61076-2-101 (M12)
3
-25...+85 °C, d ep end ing o n cab le q uality
DE
85444290
4048879199070
27279218
1
The info rmatio n in this b ro c hure has b e e n c o mp ile d with the utmo s t c are .
Liab ility fo r the c o rre c tne s s c o mp le te ne s s and to p ic ality o f the info rmatio n is re s tric te d to g ro s s ne g lig e nc e . Ve rs io n: 02/19
Mu r r e l e ktr o n i k G m b H | Fa l ke n s tr a ße 3 | 71570 O p p e n we i l e r | Fo n +49 ( 71 91) 47-0 | Fa x +49 ( 71 91) 47-491000 | s h o p @ m u r r e l e ktr o n i k.co m |