OM1905NMM OM1915NMM
OM1912NMM
HERMETIC SURFACE MOUNT FIXED VOLTAGE NEGATIVE
REGULATORS APPROVED TO DESC DRAWINGS
Three Terminal, Fixed Voltage, 1.5 Amp
Precision Negative Regulators In Hermetic
Surface Mount Package
FEATURES
•
•
•
•
•
•
Hermetic Surface Mount Package
Output Voltages: -5V, -12V, -15V
Output Voltages Set Internally To ±1%
Built-In Thermal Overload Protection
Short Circuit Current Limiting
Product Is Available Hi-Rel Screened
DESCRIPTION
These three terminal negative regulators are supplied in a hermetically sealed
surface mount package. All protective features are designed into the circuit including
thermal shutdown, current limiting and safe-area control. With heat sinking, they can
deliver over 1.5 amps of output current. These units feature internally trimmed output
voltages to ±1% of nominal voltage. Standard voltages are -5V, -12V, and
-15V. These units are ideally suited for Military applications where a hermetic surface
mount package is required.
PART NUMBER DESIGNATOR
Standard Military Drawing Number
5962-8874601 NX
5962-8874701 NX
5962-8874801 NX
Omnirel Part Number
OM1905NMM
OM1912NMM
OM1915NMM
3.5
4 11 R0
3.5 - 53
OM1905NMM - OM1915NMM
ABSOLUTE MAXIMUM RATINGS @ 25°C
Input Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -35 V
Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . .- 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C
Typical Power/Thermal Charateristics:
Rated Power @ 25° C T
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15W
T
A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3W
Thermal Resistance
θ
JC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5°C/W
aa
θ
JA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120°C/W
ELECTRICAL CHARACTERISTICS -5
Volt
Parameter
Output Voltage
Symbol
V
OUT
V
IN
= -10V, I
o
= 500mA, -55°C ≤ T
A
≤ 125°C (unless otherwise specified)
Min.
-4.95
Max.
-5.05
-5.15
Unit
V
V
Test Conditions
T
A
= 25°C
V
IN
= -7.5V to -20V
I
O
= 5mA to 1.0 A, P < 15W
•
-4.85
Line Regulation
(Note 1)
(Note 4)
V
RLINE
V
IN
= -7.5V to -20V
12
mV
mV
mV
mV
mV
mV
mV
mV
mA
mA
mA
•
V
IN
= -8.0V to -12V
25
5
•
Load Regulation
(Note 1)
I
O
= 250mA to 750 mA
V
RLOAD
I
O
= 5mA to 1.5 Amp
12
20
•
•
25
15
30
2.5
Standby Current Drain
I
SCD
∆I
SCD
(Line)
∆I
SCD
(Load)
V
DO
I
O (pk)
I
DS
∆V
IN
∆V
OUT
N
O
∆V
OUT
∆t
∆V
OUT
= 100mV, I
O
=
1.0A
T
A
= 25°C
V
IN
= -35V
I
O
= 5mA to 1000mA
V
IN
= -7.0V to -20V
Standby Current Drain
Change With Line
Standby Current Drain
Change With Load
Dropout Voltage
Peak Output Current
Short Circuit Current
(Note 2)
Ripple Rejection
•
•
•
•
1.5
3.0
0.4
0.4
mA
2.5
3.3
1.2
V
A
A
A
dB
dB
•
f =120 Hz,
∆V
IN
= -10V
(Note 3)
T
A
= 25°C, f =10 Hz to 100KHz
T
A
= 25°C, t = 1000 hrs.
63
2.8
•
60
40
Output Noise Voltage
(Note 3)
Long Term Stability
µV/V
RMS
75
mV
3.5
(Note 3)
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
IN
= -35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
3.5 - 54
OM1905NMM - OM1915NMM
ELECTRICAL CHARACTERISTICS -12 Volt
Parameter
Output Voltage
Symbol
V
OUT
V
IN
= -19V, I
o
= 500mA, -55°C ≤ T
A
≤ 125°C (unless otherwise specified)
Min.
-11.88
Max.
-12.12
-12.36
Unit
V
V
Test Conditions
T
A
= 25°C
V
IN
= -14.5V to -27V
I
O
= 5mA to 1.0 A, P < 15W
•
-11.64
Line Regulation
(Note 1)
(Note 4)
V
RLINE
V
IN
= -14.5V to -27V
20
mV
mV
mV
mV
mV
mV
mV
mV
mA
mA
mA
•
V
IN
= -16V to -22V
50
10
•
Load Regulation
(Note 1)
I
O
= 250mA to 750 mA
V
RLOAD
I
O
= 5mA to 1.5 Amp
30
32
•
•
60
16
30
3.5
Standby Current Drain
I
SCD
∆I
SCD
(Line)
∆I
SCD
(Load)
V
DO
I
O (pk)
I
DS
∆V
IN
∆V
OUT
N
O
∆V
OUT
∆t
∆V
OUT
= 100mV, I
O
=
1.0A
T
A
= 25°C, I
O
= 5mA to 1A
V
IN
= -35V
I
O
= 5mA to 1000mA
V
IN
= -14.5V to -27V
Standby Current Drain
Change With Line
Standby Current Drain
Change With Load
Dropout Voltage
Peak Output Current
Short Circuit Current
(Note 2)
Ripple Rejection
•
•
•
•
1.5
4.0
0.8
0.5
mA
1.8
3.3
1.2
V
A
A
A
dB
dB
•
f =120 Hz,
∆V
IN
= -10V
(Note 3)
T
A
= 25°C, f =10 Hz to 100KHz
T
A
= 25°C, t = 1000 hrs.
56
2.8
•
53
40
Output Noise Voltage
(Note 3)
Long Term Stability
(Note 3)
µV/V
RMS
120
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
IN
= -35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5 mA.
MECHANICAL OUTLINE
CONNECTION DIAGRAM
.140
.015
.075
.140
.140
.075
.157
1
2
.030
MIN.
Pin 1 Ground
Pin 2 Output
Pin 3 Input
3.5
.415
3
.062
.375
3.5 - 55
OM1905NMM - OM1915NMM
ELECTRICAL CHARACTERISTICS -15 Volt
Parameter
Output Voltage
Symbol
V
OUT
V
IN
= -23V, I
o
= 500mA, -55°C ≤ T
A
≤ 125°C (unless otherwise specified)
Min.
-14.85
Max.
-15.15
-15.45
Unit
V
V
Test Conditions
T
A
= 25°C
V
IN
= -17.5V to -30V
I
O
= 5mA to 1.0 A, P < 15W
•
-14.55
Line Regulation
(Note 1)
(Note 4)
V
RLINE
V
IN
= -17.5V to -30V
25
mV
mV
mV
mV
mV
mV
mV
mV
mA
mA
mA
•
V
IN
= -20V to -26V
50
15
•
Load Regulation
(Note 1)
I
O
= 250mA to 750 mA
V
RLOAD
I
O
= 5mA to 1.5 Amp
25
35
•
•
75
21
45
6.0
Standby Current Drain
I
SCD
∆I
SCD
(Line)
∆I
SCD
(Load)
V
DO
I
O (pk)
I
DS
∆V
IN
∆V
OUT
N
O
∆V
OUT
∆t
∆V
OUT
= 100mV, I
O
=
1.0A
T
A
= 25°C
V
IN
= -35V
I
O
= 5mA to 1000 mA
V
IN
= -17.5V to -30V
Standby Current Drain
Change With Line
Standby Current Drain
Change With Load
Dropout Voltage
Peak Output Current
Short Circuit Current
(Note 2)
Ripple Rejection
•
•
•
•
1.5
6.5
0.8
0.5
mA
2.5
3.3
1.2
V
A
A
A
dB
dB
•
f =120 Hz,
∆V
IN
= -10V
(Note 3)
T
A
= 25°C, f =10 Hz to 100KHz
T
A
= 25°C, t = 1000 hrs.
53
2.8
•
50
40
Output Noise Voltage
(Note 3)
Long Term Stability
(Note 3)
µV/V
RMS
150
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
IN
= -35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
TYPICAL PERFORMANCE CHARACTERISTICS
PEAK OUTPUT
3.5
3
2.5
DROPOUT VOLTAGE
100
RIPPLE REJECTION
Output Current (A)
T
j
= -55°C
2
3.5
2
T
j
= 25°C
1.5
I
OUT
= 500mA
Ripple Rejection (dB)
2.5
I
OUT
= 1A
80
V
OUT
= 5V
Output Current (A)
60
1.5
1
0.5
∆V
OUT
= 100mV
T
j
= 150°C
1
I
OUT
= 0A
40
V
IN
- V = 8V
DC
+3.5V
rms
I
OUT
= 1A
T
j
= 25°C
0.5
∆V
OUT
= 100MV
20
0
5
10
15
20
25
30
35
0
-75-50 -25 0
2 5 5 0 7 5 100 125150
0
10
100
1k
10k
Input To Output Differential (V)
Junction Temperature (°C)
Frequency (Hz)