TECHNICAL DATA SHEET
Mini-Coax
STRAIGHT JACK
23K101-101H3
All dimensions are in mm; tolerances according to ISO 2768 m-H
Documents
Assembly instruction
23 A
Material and plating
Connector parts
Center contact
Outer contact
Body
Clip
Dielectric
Crimping ferrule
Material
Beryllium copper
Brass
Brass
Beryllium copper
PTFE
Copper
Plating
Gold, min. 1.27 µm, over chemical nickel
Gold, min. 1.27 µm, over chemical nickel
Gold, min. 1.27 µm, over chemical nickel
Nickel, 2.5-5 µm
Gold, 0.1 µm min.
RF_35/12.04/3.0
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel.: +49 8684 18-0
Fax: +49 8684 18-499
email: info@rosenberger.de
Page
1/2
TECHNICAL DATA SHEET
Mini-Coax
Electrical data
Impedance
Frequency
Return loss
Insertion loss
Insulation resistance
Center contact resistance
Outer contact resistance
Test voltage
Working voltage
RF-leakage
- Limitations are possible due to the used cable type -
STRAIGHT JACK
23K101-101H3
50
Ω
DC to 6 GHz
≥
25 dB, DC to 1 GHz
≥
18 dB, 1 to 3 GHz
≤
0.1 x
f(GHz)
dB,DC to 3 GHz
3
≥
1 x10 MΩ
≤
10 mΩ
≤
3 mΩ
750 V rms
500 V rms
≥
80 dB up to 1 GHz
≥
60 dB up to 4 GHz
Mechanical data
Mating cycles
Engaging and disengaging force
≥
500
1 N to 4 N
Environmental data
Temperature range
Climatic class
Mechanical shock
-40°C to +85°C
IEC 60068-2-1 40/85/21
IEC 60068-2-2
IEC 60068-2-3
IEC 60068-2-27 50G halfsinus, 2 shocks/axis during 11 sec.
Tooling
Crimping tool
Crimp insert
11W150-000
11W150-401
Suitable cables
RG 196 A/U, RG 178 B/U
Packing
Standard
Weight
100 pcs in clap-pac
0.7 g/pce
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
RF_35/12.04/3.0
Draft
Inge Mühlauer
Date
07/09/04
Approved
Rong Fang
Date
26/10/05
Rev.
b00
Engineering change number
05-0567
Name
Inge Mühlauer
Date
26/10/05
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel.: +49 8684 18-0
Fax: +49 8684 18-499
email: info@rosenberger.de
Page
2/2