810008890/DB | O-060-LA-8W-F123G/25T/AJ
LightScope ZWP® Single Alternative Jacket/Single Armor, Gel-Filled,
Outdoor Stranded Loose Tube Cable
l
Corrugated steel tape armor is strong yet flexible, providing additional crush and rodent protection
Product Classification
Portfolio
Product Type
Regional Availability
CommScope®
Fiber OSP cable
Asia | Australia/New Zealand | EMEA | Latin America | North America
Standards And Qualifications
Cable Qualification Standards
ANSI/ICEA S-87-640 | EN 187105 | Telcordia GR-20
Representative Image
General Specifications
Cable Type
Construction Type
Subunit Type
Stranded loose tube
Armored
Gel-filled
Construction Materials
Fiber Type Solution
Jacket Material
Total Fiber Count
Armor Type
Fiber Type
G.652.D and G.657.A1
Alternative jacket PE
60
Corrugated steel
G.652.D and G.657.A1
page 1 of 3
March 27, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: December 19, 2018
810008890/DB | O-060-LA-8W-F123G/25T/AJ
Fiber Type, quantity
Fibers per Subunit, quantity
Jacket Color
Jacket UV Resistance
60
12
Black
UV stabilized
Dimensions
Buffer Tube/Subunit Diameter
Cable Weight
Diameter Over Jacket
Subunit, quantity
2.50 mm | 0.10 in
113.0 kg/km | 76.0 lb/kft
11.50 mm | 0.45 in
5
Physical Specifications
Minimum Bend Radius, loaded
Minimum Bend Radius, unloaded
17.3 cm | 6.8 in
11.5 cm | 4.5 in
Tensile Load, long term, maximum
800 N | 180 lbf
Tensile Load, short term, maximum
2700 N | 607 lbf
Vertical Rise, maximum
723.0 m | 2371.0 ft
Environmental Specifications
Environmental Space
Installation Temperature
Operating Temperature
Storage Temperature
Aerial, lashed | Buried
-30 °C to +70 °C (-22 °F to +158 °F)
-40 °C to +70 °C (-40 °F to +158 °F)
-40 °C to +75 °C (-40 °F to +167 °F)
Mechanical Test Specifications
Compression
Compression Test Method
Flex
Flex Test Method
Impact
Impact Test Method
Strain
Strain Test Method
Twist
Twist Test Method
Water Penentration
Water Penentration Test Method
44 N/mm | 250 lb/in
FOTP-41 | IEC 60794-1 E3
35 cycles
FOTP-104 | IEC 60794-1 E6
2.94 N-m | 2.17 ft lb
FOTP-25 | IEC 60794-1 E4
See long and short term tensile loads
FOTP-33 | IEC 60794-1 E1
10 cycles
FOTP-85 | IEC 60794-1 E7
24 h
FOTP-82 | IEC 60794-1 F5
page 2 of 3
March 27, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: December 19, 2018
810008890/DB | O-060-LA-8W-F123G/25T/AJ
Environmental Test Specifications
Cable Freeze
Cable Freeze Test Method
Drip
Drip Test Method
Heat Age
Heat Age Test Method
Low High Bend
Low High Bend Test Method
Temperature Cycle
Temperature Cycle Test Method
-2 °C | 28 °F
FOTP-98 | IEC 60794-1 F15
70 °C | 158 °F
FOTP-81 | IEC 60794-1 E14
-40 °C to +85 °C (-40 °F to +185 °F)
IEC 60794-1 F9
-30 °C to +60 °C (-22 °F to +140 °F)
FOTP-37 | IEC 60794-1 E11
-40 °C to +70 °C (-40 °F to +158 °F)
FOTP-3 | IEC 60794-1 F1
Regulatory Compliance/Certifications
Agency
RoHS 2011/65/EU
ISO 9001:2015
Classification
Compliant
Designed, manufactured and/or distributed under this quality management system
Included Products
DB-8W-LT (Product Component—not orderable)
—
LightScope ZWP® Singlemode Fiber
DB-8W-
Component—
ZWP®
* Footnotes
Operating Temperature
Specification applicable to non-terminated bulk fiber cable
page 3 of 3
March 27, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: December 19, 2018