) ................................................................................ See MIL-STD-1835
1.4 Recommended operating conditions.
Supply voltage range ................................................................................................................ 4.5 V dc to 5.5 V dc
Minimum high level input voltage (V
IH
):
Logic inputs ........................................................................................................................ 2.2 V dc
Clock input ......................................................................................................................... V
CC
– 0.6 V dc
Maximum low level input voltage (V
IL
):
Logic inputs ........................................................................................................................ 0.8 V dc
Clock input ......................................................................................................................... 0.45 V dc
Frequency of operation ............................................................................................................. DC to 6.17 MHz
Case operating temperature range (T
C
) .................................................................................... -55°C to +125°C
Clock rise and fall times ............................................................................................................ 20 ns maximum
________
1/ Must withstand the added P
D
due to short circuit test; e.g., I
OS
.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
A
REVISION LEVEL
5962-89514
SHEET
B
2
2. APPLICABLE DOCUMENTS
2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part
of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the
solicitation or contract.
DEPARTMENT OF DEFENSE SPECIFICATION
MIL-PRF-38535
-
Integrated Circuits, Manufacturing, General Specification for.
DEPARTMENT OF DEFENSE STANDARDS
MIL-STD-883
MIL-STD-1835
-
-
Test Method Standard Microcircuits.
Interface Standard Electronic Component Case Outlines.
DEPARTMENT OF DEFENSE HANDBOOKS
MIL-HDBK-103
MIL-HDBK-780
-
-
List of Standard Microcircuit Drawings.
Standard Microcircuit Drawings.
(Copies of these documents are available online at
http://assist.daps.dla.mil/quicksearch/
or
http://assist.daps.dla.mil
or
from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094).
2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text
of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a
specific exemption has been obtained.
3. REQUIREMENTS
3.1 Item requirements. The individual item requirements shall be in accordance with MIL-PRF-38535, appendix A for non-
JAN class level B devices and as specified herein. Product built to this drawing that is produced by a Qualified Manufacturer
Listing (QML) certified and qualified manufacturer or a manufacturer who has been granted transitional certification to MIL-
PRF-38535 may be processed as QML product in accordance with the manufacturers approved program plan and qualifying
activity approval in accordance with MIL-PRF-38535. This QML flow as documented in the Quality Management (QM) plan
may make modifications to the requirements herein. These modifications shall not affect form, fit, or function of the device.
These modifications shall not affect the PIN as described herein. A "Q" or "QML" certification mark in accordance with MIL-
PRF-38535 is required to identify when the QML flow option is used.
3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified
in MIL-PRF-38535, appendix A and herein.
3.2.1 Case outline. The case outline shall be in accordance with 1.2.2 herein.
3.2.2 Terminal connections. The terminal connections shall be as specified on figure 1.
3.2.3 Block diagram. The block diagram shall be as specified on figure 2.
3.2.4 Timing waveforms and test circuits. The timing waveforms and test circuits shall be as specified on figure 3.
3.3 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are
as specified in table I and shall apply over the full case operating temperature range.
3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical
tests for each subgroup are described in table I.
3.5 Marking. Marking shall be in accordance with MIL-PRF-38535, appendix A. The part shall be marked with the PIN
listed in 1.2 herein. In addition, the manufacturer's PIN may also be marked. For packages where marking of the entire SMD
PIN number is not feasible due to space limitations, the manufacturer has the option of not marking the "5962-" on the device.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
A
REVISION LEVEL
5962-89514
SHEET
B
3
3.5.1 Certification/compliance mark. A compliance indicator “C” shall be marked on all non-JAN devices built in compliance
to MIL-PRF-38535, appendix A. The compliance indicator “C” shall be replaced with a "Q" or "QML" certification mark in
accordance with MIL-PRF-38535 to identify when the QML flow option is used.
3.6 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to be listed as an
approved source of supply in MIL-HDBK-103 (see 6.6 herein). The certificate of compliance submitted to DLA Land and
Maritime-VA prior to listing as an approved source of supply shall affirm that the manufacturer's product meets the
requirements of MIL-PRF-38535, appendix A and the requirements herein.
3.7 Certificate of conformance. A certificate of conformance as required in MIL-PRF-38535, appendix A shall be provided
with each lot of microcircuits delivered to this drawing.
3.8 Notification of change. Notification of change to DLA Land and Maritime-VA shall be required for any change that
affects this drawing.
3.9 Verification and review. DLA Land and Maritime, DLA Land and Maritime 's agent, and the acquiring activity retain the
option to review the manufacturer's facility and applicable required documentation. Offshore documentation shall be made