UNISONIC TECHNOLOGIES CO., LTD
UR132
200mA LOW DROPOUT LINEAR
VOLTAGE REGULATOR
DESCRIPTION
The UTC
UR132
is a 200mA fixed output voltage low dropout
linear regulator. Wide range of available output voltage fits most of
applications. Built-in output current-limiting most thermal-limiting
provide maximal protection against any fault conditions.
LINEAR INTEGRATED CIRCUIT
FEATURES
* Guaranteed 200mA output current
* Input voltage range up to 12V
* Extremely tight load regulation
* Fast transient response
* Current-limiting and thermal-limiting
* Three-terminal adjustable or fixed voltage.
ORDERING INFORMATION
Ordering Number
Lead Free
Halogen Free
UR132L-xx-AE3-3-R
UR132G-xx-AE3-3-R
SOT-23
UR132L-xx-AE3-5-R
UR132G-xx-AE3-5-R
SOT-23
UR132L-xx-AF5-C-R
UR132G-xx-AF5-C-R
SOT-25
Note: Pin assignment: I:V
IN
O:V
OUT
G:GND N: No Connection
xx: output voltage, refer to Marking Information
Package
Pin Assignment.
1
2
3
4
5
O G
I
-
-
G O
I
-
-
I
G N N O
Packing
Tape Reel
Tape Reel
Tape Reel
www.unisonic.com.tw
Copyright © 2011 Unisonic Technologies Co., Ltd
1 of 4
QW-R102-007,J
UR132
MARKING INFORMATION
PACKAGE
VOLTAGE CODE
Pin Assignment
LINEAR INTEGRATED CIRCUIT
MARKING
SOT-23
SOT-25
12: 1.2V
15 : 1.5V
18: 1.8V
22: 2.2V
2E: 2.5V
26: 2.6V
27: 2.7V
28: 2.8V
30: 3.0V
33: 3.3V
50: 5.0V
AD: ADJ
OGI
Voltage Code
RXX
L: Lead Free
G: Halogen Free
GOI
Voltage Code
5
RXX5
L: Lead Free
G: Halogen Free
4
IGNNO
Voltage Code
1
RXX
2
3
L: Lead Free
G: Halogen Free
BLOCK DIAGRAM
V
IN
+
Current Amp
V
REF
1.25V
+
-
Themal Limit
Current Limit
V
OUT
For
Fixed
Voltage
Device
ADJ
GND
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
2 of 4
QW-R102-007,J
UR132
ABSOLUTE MAXIMUM RATINGS
PARAMETER
LINEAR INTEGRATED CIRCUIT
SYMBOL
RATING
UNIT
Input Voltage
V
IN
-0.3~12
V
Power Dissipation
P
D
300
mW
Junction Temperature
T
J
+125
°C
Operation Temperature
T
OPR
-40~+85
°C
Storage Temperature
T
STG
-40~+150
°C
Note: Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Absolute maximum ratings are stress ratings only and functional device operation is not implied.
ELECTRICAL CHARACTERISTICS
(Ta=25°C, C
IN
=1μF, C
OUT
=10μF, unless otherwise specified)
FOR V
OUT
<3.3V
(V
OUT
±2%)
PARAMETER
Output Voltage
Output Voltage Temperature Coefficient
Line Regulation
Load Regulation (Note 2)
Current Limit (Note 3)
Dropout Voltage (Note 4,5)
Standby current
SYMBOL
TEST CONDITIONS
V
OUT
I
L
=2mA, V
IN
-V
OUT
=2V
T
C
V
O
I
L
=2mA,
△
V
OUT
V
IN
-V
OUT
=2V~V
IN
=9V
I
L
=2mA~200mA,
△
V
OUT
V
IN
-V
OUT
=2V
I
L
V
IN
-V
OUT
=2V, V
OUT
=0V
V
D
I
STN-BY
I
L
=0, V
IN
=9V
MIN
V
OUT
×0.98
TYP
MAX
UNIT
V
OUT
V
OUT
×1.02
V
50
150
ppm/°C
0.5
10
300
1.5
3.0
30
%V
OUT
mV
mA
V
mA
FOR ADJ and V
OUT
≥3.3V
(V
OUT
±2%)
PARAMETER
SYMBOL
TEST CONDITIONS
MIN
TYP
MAX
UNIT
Output Voltage
V
OUT
I
L
=2mA, V
IN
-V
OUT
=2V
V
OUT
×0.98 V
OUT
V
OUT
×1.02
V
ADJUSTABLE
(R1=120Ω,R2=200Ω,V
OUT
=3.3V)
Reference Voltage
V
REF
V
IN
-V
OUT
=2V, I
L
=2mA
1.238
1.250
1.262
V
Output Voltage Temperature Coefficient
T
C
V
O
50
150
ppm/°C
I
L
=2mA,
0.5
%V
OUT
Line Regulation
△
V
OUT
V
IN
-V
OUT
=2V~V
IN
=12V
I
L
=2mA~200mA,
10
30
mV
Load Regulation (Note 2)
△
V
OUT
V
IN
-V
OUT
=2V
Current Limit (Note 3)
I
L
V
IN
-V
OUT
=2V, V
OUT
=0V
300
mA
Dropout Voltage (Note 4,5)
V
D
1.3
V
Standby current
I
STN-BY
I
L
=0, V
IN
=12V
5.0
mA
Note: 1. Guaranteed by design.
2. Regulation is measured at constant junction temperature, using pulsed on time.
3. Current limit is measured at constant junction temperature, using pulsed on time.
4. Dropout is measured at constant junction temperature, using pulsed on time, and the criterion is V
OUT
inside
target value±2%.
5. Dropout test is skipped at the condition of V
IN
<3V.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
3 of 4
QW-R102-007,J
UR132
TYPICAL APPLICATION CIRCUIT
LINEAR INTEGRATED CIRCUIT
The part may oscillate without the capacitor, a 10μF (or larger) capacitor is recommended between V
OUT
and
GND for stability. Any type of capacitor can be used, but not Aluminum electrolytic when operating below -20°C. The
capacitance may be increased without limit. Besides, another 1μF capacitor (or larger) should be placed between V
IN
to GND.
UR132 ADJUSTABLE
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
4 of 4
QW-R102-007,J