电子工程世界电子工程世界电子工程世界

关键词

搜索

型号

搜索

34-0002-182BTL

产品描述Interconnection Device
产品类别连接器    连接器   
文件大小184KB,共3页
制造商Aries Electronics
下载文档 详细参数 全文预览

34-0002-182BTL概述

Interconnection Device

34-0002-182BTL规格参数

参数名称属性值
Reach Compliance Codecompliant
连接器类型INTERCONNECTION DEVICE
Base Number Matches1

文档预览

下载PDF文档
Series 181 Thru 183
90° Pin Staked Flex Jumpers
FEATURES:
• Aries 90° Pin Staked Flex Jumpers combine thin, flexible, solid Copper conductors
embedded between layers of tough, flexible, flame-retardant insulation.
• Consult factory for cable lengths under 2.000 [50.80].
• See Data Sheet
11005
for Flat Pin Staked Flex Jumpers
GENERAL SPECIFICATIONS:
• Standard cable insulation is white UL VW-1, Style 2643 flame retardant Polyester
(Mylar) adhesive.
• High temperature flame retardant cable insulation is Polyimide (Kapton) insulation
with acrylic adhesive.
• Cable conductors are solid Copper with a cross-sectional area equivalent to that
of 26 gauge AWG.
• Female housing is black UL 94V-0 Glass-filled Stanyl 4/6 Nylon.
• Female and male “crimp-on” pins are spring-tempered Copper Alloy 510.
• Female and male pin plating:
T
= 100μ” [2.54μm] min. Matte Tin per ASTM-B545-97 over 50μ” Min. Nickel per
ASTM-AMS-QQ-N-290
TL
= 100μ” [2.54μm] min. 93/7 Tin/Lead per SAE-AMS-P-81728 over 50μ”
[1.27μm] min. Nickel per SAE-AMS-QQ-N-290.
• Cable current rating=3 Amps
• Cable voltage rating=300 Volts
• Cable dielectric strength=2500 Volts/mil, minimum (standard)
=4000 Volts/mil, minimum (high temp)
• Cable insulation resistance=1000 MOhms minimum (standard)
=100,000 MOhms (high temp)
•Conductor/Contact Resistance (avg.) = 20mOhms initial (max. 20mOhm increase)
based on a 2”cable @20°C.
•Operating temperature=67 to 257°F [-55 to 105°C].
• Female housing accepts leads .024-.030 [.61-.76] square,
.150 [3.81] long minimum.
MOUNTING CONSIDERATIONS:
• Suggested PCB hole size=.032+ .002 .81 + .05] dia.
No. of Conductors:
(4 – 40)
Cable Length:
“L” in inches
(2” min. length)
Ex: -0002- = 2”
-02.5 = 2.5”
Jumper Series:
181: Male both ends
182: Male/Female (tin)
183: Female (tin) both ends
XX-XXXX-181A
XX-XXXX-181AP
XX-XXXX-181ATL
XX-XXXX-181AHT
XX-XXXX-181APTL
XX-XXXX-181APHT
XX-XXXX-181APTLHT
XX-XXXX-181B
XX-XXXX-181BP
XX-XXXX-181BTL
XX-XXXX-181BHT
XX-XXXX-181BPTL
XX-XXXX-181BPHT
XX-XXXX-181BPTLHT
XX-XXXX-181C
XX-XXXX-181CP
XX-XXXX-181CTL
XX-XXXX-181CHT
XX-XXXX-181CPTL
XX-XXXX-181CPHT
XX-XXXX-181CPTLHT
XX-XXXX-182A
XX-XXXX-182AP
XX-XXXX-182ATL
XX-XXXX-182AHT
XX-XXXX-182APTL
XX-XXXX-182APHT
XX-XXXX-182APTLHT
XX-XXXX-182B
XX-XXXX-182BP
XX-XXXX -182BTL
XX-XXXX-182BHT
XX-XXXX-182BPTL
XX-XXXX-182BPHT
XX-XXXX-182BPTLHY
XX-XXXX-182C
XX-XXXX-182CP
XX-XXXX-182CTL
XX-XXXX-182CHT
XX-XXXX-182CPTL
XX-XXXX-182CPHT
XX-XXXX-182CPTLHT
Note: Aries specializes in custom design and production. In addition to
the standard products shown on this page, special materials, platings,
sizes, and configurations can be furnished, depending on quantities.
Aries reserves the right to change product specifications without notice.
A
LL DIMENSIONS
:
INCHES
[
MILLIMETERS
]
All tolerances
+ .005 [.13] unless otherwise specified
Kapton is a registered trademark for DuPont
**Aries reserves the right to ship with
or without a polarization stripe unless
otherwise specified by customer
“A”=NO. OF CONDUCTORS X .100 [2.54]
“B”=(NO. OF CONDUCTORS -1) X .100 [2.54]
ORDERING INFORMATION
XX-XXXX-18X X X XX XX
“HT”=High temperature cable insulation
“TL” = Tin/Lead Plating
“P”=Polarization stripe included
Bend Options:
“A” = Both ends bent 90?, same direction
“B” = One male end bent 90?
“C” = Both ends bent 90?, opposite direction
“D” = One female end bent 90?
XX-XXXX -182D
XX-XXXX-182DP
XX-XXXX-182DTL
XX-XXXX-182DHT
XX-XXXX-182DPTL
XX-XXXX-182DPHT
XX-XXXX-182DPTLHT
XX-XXXX-183A
XX-XXXX-183AP
XX-XXXX-183ATL
XX-XXXX-183AHT
XX-XXXX-183APTL
XX-XXXX-183APHT
XX-XXXX-186APTLHT
XX-XXXX-183C
XX-XXXX-183CP
XX-XXXX-183CTL
XX-XXXX-183CHT
XX-XXXX-183CPTL
XX-XXXX-183CPHT
XX-XXXX-183CPTLHT
XX-XXXX-183D
XX-XXXX-183DP
XX-XXXX-183DTL
XX-XXXX-183DHT
XX-XXXX-183DPTL
XX-XXXX-183DPHT
XX-XXXX-183DPTLHT
http://www.arieselec.com • info@arieselec.com
NORTH AMERICA
Frenchtown, NJ USA
TEL:(908) 996-6841
FAX:(908) 996-3891
abc
EUROPE
TEL: +44 870 240 0249
FAX: +44 871 919 6033
europe@arieselec.com
11019
REV.H
Page
1 of 3
PRINTOUTS OF THIS DOCUMENT MAY BE OUT OF DATE AND SHOULD BE CONSIDERED UNCONTROLLED
基于CC2652R的zigbee 3.0万能网关协调器
采用CC2652,使用LAUNCHXL-CC26X2R1开发板。串口接树莓派。 CC2652的网协调器,基于优化的simplelinkTI-RTOS。 1,优化无线收发接口,每个无线发送都会产生对应的confirm软中断命令,防止连 ......
罗菜鸟 无线连接
一封来自大四学生的信,虚心请教
开始做一下自我介绍吧,我是一名湘潭大学05级自动化专业的学生。性格能内能外,觉得 还应该不断完美。下面说一说我大学前面三年的生活吧。 大一大二没学什么课外的知识,平平淡淡, ......
liss6000 嵌入式系统
问一下关于LM35CZ温度传感器的问题
是这样的,小弟前几天在网上买了一个LM35CZ温度传感器,然后用仿真做了一个电路没问题,用这个传感器手册上给的双电源模式供电的时候,一接上我的稳压源就短路,请问这是怎么回事,感觉是传感器 ......
StruggleMySen 传感器
嵌入式系统建模资料
台湾UML专家高焕堂讲解嵌入式系统建模的好书,下面是书的内容简介: UML是当今最流行的标准建模语言,它与嵌入式系统设计愈来愈密切。本书深入浅出地介绍 了两者之间的密切关系,并通过 ......
dswybs 嵌入式系统
智能电网之电能质量监测仪-硬件结构设计
废话说在前面:这次是为了水帖,因为上个帖子是去年发的,要水一帖表示拒绝烂尾{:1_122:} 上一期肤浅的介绍了一下几种实现方案,这一次发个硬件和结构的帖子凑个数,也分享一点硬件的 ......
elvike 工业自动化与控制
低噪声晶体管放大器的设计
摘要以实现声频放人器低澡声化为出发点,阐述了具体设计的几个方面.从低噪声放大器设计的基本原理和方法入手,对晶体管放人器的噪声模型作了分析,并推导出一种实用的最佳源电阻近似求法.还对系 ......
JasonYoo 模拟电子

 
EEWorld订阅号

 
EEWorld服务号

 
汽车开发圈

 
机器人开发圈

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程 索引文件: 2843  710  1658  2761  737  5  28  18  47  4 

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区中关村大街18号B座15层1530室 电话:(010)82350740 邮编:100190

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved