电子工程世界电子工程世界电子工程世界

关键词

搜索

型号

搜索

32-002.25-182BPTL

产品描述Interconnection Device
产品类别连接器    连接器   
文件大小227KB,共3页
制造商Aries Electronics
下载文档 详细参数 全文预览

32-002.25-182BPTL概述

Interconnection Device

32-002.25-182BPTL规格参数

参数名称属性值
Reach Compliance Codecompliant
连接器类型INTERCONNECTION DEVICE
Base Number Matches1

文档预览

下载PDF文档
Series 181 Thru 183
90° Pin Staked Flex Jumpers
FEATURES:
• Aries 90° Pin Staked Flex Jumpers combine thin, flexible, solid Copper conductors
embedded between layers of tough, flexible, flame-retardant insulation.
• Consult factory for cable lengths under 2.000 [50.80].
• See Data Sheet
11005
for Flat Pin Staked Flex Jumpers
• For RoHS applications for Lead-Free Soldering use HT Cable
GENERAL SPECIFICATIONS:
• Standard cable insulation is white UL VW-1, Style 2643 flame retardant Polyester
(Mylar) adhesive.
• High temperature flame retardant cable insulation is Polyimide (Kapton) insulation
with acrylic adhesive.
• Cable conductors are solid Copper with a cross-sectional area equivalent to that
of 26 gauge AWG.
• Female housing is black UL 94V-0 Glass-filled Stanyl 4/6 Nylon.
• Female and male “crimp-on” pins are spring-tempered Copper Alloy 510.
• Female and male pin plating:
T
= 100μ” [2.54μm] min. Matte Tin per ASTM-B545-97 over 50μ” Min. Nickel per
ASTM-AMS-QQ-N-290
TL
= 100μ” [2.54μm] min. 93/7 Tin/Lead per SAE-AMS-P-81728 over 50μ”
[1.27μm] min. Nickel per SAE-AMS-QQ-N-290.
• Cable current rating=3 Amps
• Cable voltage rating=300 Volts
• Cable dielectric strength=2500 Volts/mil, minimum (standard)
=4000 Volts/mil, minimum (high temp)
• Cable insulation resistance=1000 MOhms minimum (standard)
=100,000 MOhms (high temp)
•Conductor/Contact Resistance (avg.) = 20mOhms initial (max. 20mOhm increase)
based on a 2”cable @20°C.
•Operating temperature=67 to 257°F [-55 to 105°C].
• Female housing accepts leads .024-.030 [.61-.76] square,
.150 [3.81] long minimum.
MOUNTING CONSIDERATIONS:
• Suggested PCB hole size=.032+ .002 .81 + .05] dia.
No. of Conductors:
(4 – 40)
Note: Aries specializes in custom design and production. In addition to
the standard products shown on this page, special materials, platings,
sizes, and configurations can be furnished, depending on quantities.
Aries reserves the right to change product specifications without notice.
A
LL DIMENSIONS
:
INCHES
[
MILLIMETERS
]
All tolerances
+ .005 [.13] unless otherwise specified
Kapton is a registered trademark for DuPont
**Aries reserves the right to ship with
or without a polarization stripe unless
otherwise specified by customer
“A”=NO. OF CONDUCTORS X .100 [2.54]
“B”=(NO. OF CONDUCTORS -1) X .100 [2.54]
ORDERING INFORMATION
XX-XXXX-18X X X XX XX
Optional Suffix:
“HT”=High temperature cable insulation
Optional Suffix:
“TL” = Tin/Lead Plating
Optional Suffix:
“P”=Polarization stripe included
Cable Length: “L” in inches
Min. Cable Length = 2.00” (-002)
2” = -002-
2.5” = -002.5-
2.25” = -002.25-
2.125” = -002.125-
Jumper Series:
181: Male both ends
182: Male/Female (tin)
183: Female (tin) both ends
Bend Options:
“A” = Both ends bent 90°, same direction
“B” = One male end bent 90°
“C” = Both ends bent 90°, opposite direction
“D” = One female end bent 90°
XX-XXXX-182B
XX-XXXX-182BP
XX-XXXX -182BTL
XX-XXXX-182BHT
XX-XXXX-182BPTL
XX-XXXX-182BPHT
XX-XXXX-182BPTLHY
XX-XXXX-182C
XX-XXXX-182CP
XX-XXXX-182CTL
XX-XXXX-182CHT
XX-XXXX-182CPTL
XX-XXXX-182CPHT
XX-XXXX-182CPTLHT
XX-XXXX -182D
XX-XXXX-182DP
XX-XXXX-182DTL
XX-XXXX-182DHT
XX-XXXX-182DPTL
XX-XXXX-182DPHT
XX-XXXX-182DPTLHT
XX-XXXX-183A
XX-XXXX-183AP
XX-XXXX-183ATL
XX-XXXX-183AHT
XX-XXXX-183APTL
XX-XXXX-183APHT
XX-XXXX-183APTLHT
XX-XXXX-183C
XX-XXXX-183CP
XX-XXXX-183CTL
XX-XXXX-183CHT
XX-XXXX-183CPTL
XX-XXXX-183CPHT
XX-XXXX-183CPTLHT
XX-XXXX-183D
XX-XXXX-183DP
XX-XXXX-183DTL
XX-XXXX-183DHT
XX-XXXX-183DPTL
XX-XXXX-183DPHT
XX-XXXX-183DPTLHT
XX-XXXX-181A
XX-XXXX-181AP
XX-XXXX-181ATL
XX-XXXX-181AHT
XX-XXXX-181APTL
XX-XXXX-181APHT
XX-XXXX-181APTLHT
XX-XXXX-181B
XX-XXXX-181BP
XX-XXXX-181BTL
XX-XXXX-181BHT
XX-XXXX-181BPTL
XX-XXXX-181BPHT
XX-XXXX-181BPTLHT
XX-XXXX-181C
XX-XXXX-181CP
XX-XXXX-181CTL
XX-XXXX-181CHT
XX-XXXX-181CPTL
XX-XXXX-181CPHT
XX-XXXX-181CPTLHT
XX-XXXX-182A
XX-XXXX-182AP
XX-XXXX-182ATL
XX-XXXX-182AHT
XX-XXXX-182APTL
XX-XXXX-182APHT
XX-XXXX-182APTLHT
http://www.arieselec.com • info@arieselec.com
PRINTOUTS OF THIS DOCUMENT MAY BE OUT OF DATE AND SHOULD BE CONSIDERED UNCONTROLLED
Bristol, PA
USA
TEL:
(215) 781-9956
FAX:
(215) 781-9845
abc
11019
REV.K
Page
1 of 3
【MSP430共享】基于MSP430单片机的开关稳压电源设计
摘要:介绍基于MSP430单片机的开关稳压电源的系统结构和总设计方案。该设计硬件电路由整流滤波电路、升压斩波电路、PWM驱动电路及保护电路组成。该系统的软件是在IAR Embedded Workbench开发环 ......
hangsky 微控制器 MCU
第一次画板子,做出来后JTAG烧不进去程序,我哭
434481434482这是为JTAG的原理图,完全抄的ti的... 434483这是我的晶振,自己当时不知道...还把晶振放到了反面,另一面还走了spi信号,不懂这是不是我烧不进去的原因... 电源方面自己都检 ......
桃凯闻 PCB设计
经验分享:如何成为一名优秀的电源设计工程师?
本人做过技术开发工作多年,从焊电路板的小工程师逐渐做到项目经理、研发经理,现在做到总工程师,作为工程师有亲身的感受,作为研发主管,对工程师的性格、心理和知识结构有非常深入的了解,现 ......
zero3360 电源技术
子时团队DIY坦克体验报告
近期一直在进行遥控坦克的改进所以很少来EE和大家交流,昨天有一位网名“德库拉”的网友给我们团队发来一份《子时团队DIY坦克体验报告》。收到这份报告我们感觉很惊讶,居然有这么细致的玩家体 ......
@ZiShi DIY/开源硬件专区
在msp430头文件里的10u,100u这些是怎么回事?
不符合变量命名规则也没有宏定义,无端地就出现了个XXu这么个东西……请问下它是什么意思呢? 我是在msp430g2553.h看到的。 #define ADC10SSEL_0 (0*8u) /* ADC10OSC */ ......
oiuwer 微控制器 MCU
串口问题:为什么串口得到的发动机转速是 字节乘以256的权?为什么是256的权呢?
串口问题:为什么串口得到的发动机转速是 字节乘以256的权?为什么是256的权呢?...
yly1985 嵌入式系统

 
EEWorld订阅号

 
EEWorld服务号

 
汽车开发圈

 
机器人开发圈

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程 索引文件: 2830  185  1154  2819  1873  13  28  25  55  51 

器件索引   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

北京市海淀区中关村大街18号B座15层1530室 电话:(010)82350740 邮编:100190

电子工程世界版权所有 京B2-20211791 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号 Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved