760229476 | P-002-DZ-5G-FSULM
LazrSPEED® Plenum Distribution Cable, interlocking aluminum armored
with plenum jacket, 2 fiber single-unit
Product Classification
Portfolio
Product Type
Regional Availability
CommScope®
Fiber indoor cable
Asia | Australia/New Zealand | EMEA | Latin America | North America
Standards And Qualifications
Cable Qualification Standards
ANSI/ICEA S-83-596 | Telcordia GR-409
Representative Image
General Specifications
Cable Type
Construction Type
Subunit Type
Distribution
Armored
Gel-free
Construction Materials
Fiber Type Solution
Total Fiber Count
Armor Type
OM5, LazrSPEED® wideband
2
Interlocking aluminum
page 1 of 3
March 30, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: February 4, 2019
760229476 | P-002-DZ-5G-FSULM
Fiber Type
Fiber Type, quantity
Jacket Color
OM5, LazrSPEED® wideband
2
Lime green
Dimensions
Cable Weight
Diameter Over Armor
Diameter Over Jacket
133.0 kg/km | 89.0 lb/kft
10.80 mm | 0.43 in
12.80 mm | 0.50 in
Physical Specifications
Minimum Bend Radius, loaded
Minimum Bend Radius, unloaded
25.7 cm | 10.1 in
18.0 cm | 7.1 in
Tensile Load, long term, maximum
45 lbf | 200 N
Tensile Load, short term, maximum
150 lbf | 667 N
Vertical Rise, maximum
154.0 m | 505.2 ft
Flame Test Specifications
Flame Test Listing
Flame Test Method
NEC OFCP (ETL) and c(ETL)
NFPA 262
Environmental Specifications
Environmental Space
Installation Temperature
Operating Temperature
Storage Temperature
Plenum
0 °C to +70 °C (+32 °F to +158 °F)
-20 °C to +70 °C (-4 °F to +158 °F)
-40 °C to +70 °C (-40 °F to +158 °F)
Mechanical Test Specifications
Compression
Compression Test Method
Flex
Flex Test Method
Impact
Impact Test Method
Strain
Strain Test Method
Twist
Twist Test Method
page 2 of 3
March 30, 2019
485 lb/in | 85 N/mm
FOTP-41 | IEC 60794-1 E3
25 cycles
FOTP-104 | IEC 60794-1 E6
25.80 ft lb | 35.00 N-m
FOTP-25 | IEC 60794-1 E4
See long and short term tensile loads
FOTP-33 | IEC 60794-1 E1
10 cycles
FOTP-85 | IEC 60794-1 E7
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: February 4, 2019
760229476 | P-002-DZ-5G-FSULM
Environmental Test Specifications
Heat Age
Heat Age Test Method
Low High Bend
Low High Bend Test Method
Temperature Cycle
Temperature Cycle Test Method
-20 °C to +85 °C (-4 °F to +185 °F)
IEC 60794-1 F9
-20 °C to +70 °C (-4 °F to +158 °F)
FOTP-37 | IEC 60794-1 E11
-20 °C to +70 °C (-4 °F to +158 °F)
FOTP-3 | IEC 60794-1 F1
Regulatory Compliance/Certifications
Agency
RoHS 2011/65/EU
ISO 9001:2015
Classification
Compliant
Designed, manufactured and/or distributed under this quality management system
Included Products
CS -5G-TB (Product Component—not orderable)
—
LazrSPEED ® OM5 WideBand Multimode Fiber
CS-5G-
Component—
LazrSPEED®
* Footnotes
Operating Temperature
Specification applicable to non-terminated bulk fiber cable
page 3 of 3
March 30, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: February 4, 2019