1. Stresses greater than those listed under ABSOLUTE MAXIMUM RATINGS may cause
permanent damage to the device. This is a stress rating only and functional operation
of the device at these or any other conditions above those indicated in the operational
sections of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect reliability.
QSOP / SSOP/ TSSOP
TOP VIEW
FUNCTION TABLE
(1)
Inputs
OE
L
L
H
NOTE:
1. H = HIGH Voltage Level
L = LOW Voltage Level
X = Don't Care
S
L
H
X
Function
A Port = B1 Port
A Port = B2 Port
Disconnect
OPERATING CHARACTERISTICS, T
A
= 25°C
(1)
Symbol
V
CC
V
IH
V
IL
T
A
Parameter
Supply Voltage
High-Level Control Input Voltage
Low-Level Control Input Voltage
Operating Free-Air Temperature
V
CC
= 2.3V to 2.7V
V
CC
= 2.7V to 3.6V
V
CC
= 2.3V to 2.7V
V
CC
= 2.7V to 3.6V
NOTE:
1. All unused control inputs of the device must be held at V
CC
or GND to ensure proper device operation.
Test Conditions
Min.
2.3
1.7
2
—
—
−40
Max.
3.6
—
—
0.7
0.8
85
Unit
V
V
V
°C
2
IDT74CBTLV3257
LOW-VOLTAGE QUAD 2:1 MUX/DEMUX BUS SWITCH
INDUSTRIAL TEMPERATURE RANGE
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE
Following Conditions Apply Unless Otherwise Specified:
Operating Conditions: T
A
= –40°C to +85°C
Symbol
V
IK
I
I
I
OZ
I
OFF
I
CC
∆I
CC
(2)
C
I
C
IO(OFF)
Control Inputs
Control Inputs
A Port
B Port
V
CC
= 2.3V
Typ. at V
CC
= 2.5V
Parameter
Control Inputs, Data Inputs
Control Inputs
Data I/O
V
CC
= 3V, I
I
= –18mA
V
CC
= 3.6V, V
I
= V
CC
or GND
V
CC
= 3.6V, V
O
= 0 or 3.6V, switch disabled
V
CC
= 0, V
I
or V
O
= 0 to 3.6V
V
CC
= 3.6V, I
O
= 0, V
I
= V
CC
or GND
V
CC
= 3.6V, one input at 3V, other inputs at V
CC
or GND
V
I
= 3V or 0
V
O
= 3V or 0,
OE
= V
CC
= 3.3V
V
I
= 0
V
I
= 1.7V
V
I
= 0
V
CC
= 3V
V
I
= 2.4V
I
O
= 64mA
I
O
= 24mA
I
O
= 15mA
I
O
= 64mA
I
O
= 24mA
I
O
= 15mA
Test Conditions
Min.
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Typ.
(1)
—
—
—
—
—
—
4
13
6
5
5
27
5
5
10
Max.
–1.2
±1
20
50
10
300
—
—
—
8
8
40
7
7
15
Unit
V
µA
µA
µA
µA
µA
pF
pF
R
ON
(3)
Ω
NOTES:
1. Typical values are at V
CC
= 3.3V, +25°C ambient.
2. The increase in supply current is attributable to each current that is at the specified voltage level rather than V
CC
or GND.
3. This is measured by the voltage drop between the A and B terminals at the indicated current through the switch. On-state resistance is determined by the lower of the voltages
of the two (A or B ) terminals.
SWITCHING CHARACTERISTICS
V
CC
= 2.5V ± 0.2V
Symbol
t
PD
(1)
t
SEL
t
EN
t
DIS
t
EN
t
DIS
Parameter
Propagation Delay
A to B or B to A
Select Time
S to A or B
Enable Time
S to B
Disable Time
S to B
Output Enable Time
OE
to A or B
Output Disable Time
OE
to A or B
NOTE:
1. The propagation delay is the calculated RC time constant of the typical on-state resistance of the switch and the specified load capacitance driven by an ideal voltage source
(zero output impedance).
V
CC
= 3.3V ± 0.3V
Max.
0.15
6.1
6.1
4.8
5.6
5.5
Min.
−
1
1
1
1
1
Max.
0.25
5.3
5.3
4.5
5
5.5
Unit
ns
ns
ns
ns
ns
ns
Min.
−
1
1
1
1
1
3
IDT74CBTLV3257
LOW-VOLTAGE QUAD 2:1 MUX/DEMUX BUS SWITCH
INDUSTRIAL TEMPERATURE RANGE
TEST CIRCUITS AND WAVEFORMS
TEST CONDITIONS
Symbol
V
LOAD
V
IH
V
T
V
LZ
V
HZ
C
L
V
CC(1)
= 3.3V±0.3V
6
3
1.5
300
300
50
V
CC(2)
= 2.5V±0.2V
2 x Vcc
Vcc
Vcc / 2
150
150
30
Unit
V
V
V
mV
mV
pF
SAME PHASE
INPUT TRANSITION
t
PLH
OUTPUT
t
PLH
OPPOSITE PHASE
INPUT TRANSITION
t
PHL
t
PHL
V
IH
V
T
0V
V
OH
V
T
V
OL
V
IH
V
T
0V
Propagation Delay
V
CC
500Ω
Pulse
Generator
(1, 2)
V
LOAD
Open
GND
CONTROL
INPUT
ENABLE
DISABLE
V
IN
D.U.T.
R
T
V
OUT
t
PZL
OUTPUT
SWITCH
NORMALLY
CLOSED
LOW
t
PZH
OUTPUT
SWITCH
NORMALLY
OPEN
HIGH
V
LOAD/2
V
T
t
PHZ
V
T
0V
t
PLZ
V
IH
V
T
0V
V
LOAD/2
V
OL +
V
LZ
V
OL
V
OH
V
OH -
V
HZ
0V
500Ω
C
L
Test Circuits for All Outputs
DEFINITIONS:
C
L
= Load capacitance: includes jig and probe capacitance.
语音作为自然的人机接口,可以使车载导航系统实现更安全、更人性化的操作。通过国内外车载导航系统的功能对比可知,支持语音交互是车载导航系统的一个发展趋势。另外,市场信息服务公司J.D Power and Associates的调研数据也表明,56%的消费者更倾向于选择声控的导航系统。因此,开发车载语音导航系统是很有意义的。目前,国内已经具备开发车载语音导航系统的技术基础,特别是文语转换TTS技术...[详细]
中风发生时,一切都是以秒来计算的。延误治疗可能导致大脑重大损伤。伦敦大学医学院的一位博士Alistair McEwan已经获得行为医学研究所(Action Medical Research)的同意,为急救人员开发一种无线诊断系统来减少时间延误。感谢抗血栓药物,一些病人在病情发作的三个小时之内可以完全恢复。但出血也会导致中风。医生在治疗之前需要确定发病原因,因为不适当的服用抗血栓药物会加重损害。...[详细]
SynQor推出超小的病人全接触型400W医疗电源模块,该电源模块的封装为3×5×1.44,功率密度高达18.3W/立方英寸,转换效率达91%。 SynQor通过推出首款专门针对医疗应用而研制的AC/DC电源模块,使得公司的多元化战略持续成功地延伸至新的医疗领域。ACuQor模块系列实现了在3×5×1.44有限尺寸上提供400W的有用功率。SynQor可以提供48V,36V or 24V的...[详细]