SCD#QM5321
Source Control Drawing
Upscreening/Manufacturing Specification P/N FT1012AMH/883-LT
Title Page ................................................................................
List of Effective Pages ..............................................................
Change List ..............................................................................
Definitions .................................................................................
Acronyms and Abbreviations .....................................................
1
2
3
3.1
3.2
3.3
4
4.1
5
5.1
6
6.1
7
8
8.1
8.2
8.3
8.4
Contents.
Introduction/Purpose .................................................................
Reference Documents ...............................................................
Source of Parts.........................................................................
Original Part Manufacturer .........................................................
Screening Company...................................................................
UK Supplier...............................................................................
Manufacturing ...........................................................................
Screening .................................................................................
Certificate of Conformity ............................................................
FT Certificate of Conformity .......................................................
Package Description..................................................................
Marking ....................................................................................
Traceability ...............................................................................
Component selection .................................................................
General ....................................................................................
Nuclear Hardness ......................................................................
Baseline Component .................................................................
Obsolescence notice .................................................................
Date-20/2/04
Date-
Date-
Date-
Date-
Date-
iss-1
iss-
iss-
iss-
iss-
iss-
Rev-
Rev-
Rev-
Rev-
Rev-
Rev-
Changes-Orig
Changes-
Changes-
Changes-
Changes-
Changes-
Name-MLSalmon
Name-
Name-
Name-
Name-
Name-
TM
Force Technologies Ltd
2003
1
INTRODUCTION/PURPOSE
This document specifies the manufacturing, procurement details and screening requirements.
In brief the part is: Compensated Precision Op-Amp TO-5 can processed to Mil-Std-883 5005
A package description is given in section 6 of this document.
REFERENCE DOCUMENTS
Test Method and procedures for
Microcircuits
General Specs for Hybrids
Sort, incoming and outgoing
Inspection procedures
2
MIL-STD-883
(latest issue)
MIL-PRF-38534 or 5
Department of Defence
Washington
DC 20363-5100, USA
3
SOURCE OF PARTS
This section provides an overview of the companies involved in the manufacture, screening and supply of the
part. Original procurement of parts shall be from the address specified in section 3.3.
Original Part Manufacturer
The original part: die are/were produced by : Linear Technology
Manufacturer:LT
Address:
USA
3.1
The donor part number is: LT1012
3.2
Assy /Manu,/Screening Company
The above parts are then assembled and screened by:
Classified Disclosure under NDA or disclosed as:
3.3
UK Supplier
The assembled/screened parts shall be procured from:
Tel: +44(0)1264 731200
Force Technologies Ltd
Fax: +44(0)1264 731444
Ashley Court,
Henley,
Marlborough,
Wilts, UK
SN8 3RH
The Force Technologies part number(Ordering Code) is:
FT1012AMH/883-LT QM5321
4.0
Manufacture
(Manufacturing processes, assembly, Screen and test equipment listings available for inspection upon request.
Part Number breakdown
FT1012AMH/883-LT
A
=
spec
M
=
Mil temp
H
=
T0-5
883
=
Mil-Std-883
M5005
LT
=
Lin Tech Die
4.1
SCREENING
The FT1012AMH/883-LT- shall be screened as specified in the table below.
All batches of parts shall be supplied with a Certificate of Conformity. The certificate of conformity shall reference the
screening specified below.
Screening
Visual Inspection
Internal Visual (Pre-Cap)
Destructive tests
Temperature cycling
Constant acceleration
Seal
a. Fine
b. Gross
Visual inspection
Interim Electrical
Burn-in test
Percentage defective
allowable (PDA)
Final electrical test
Final electrical test
A) Static Tests 5005
1)Subgroups 1(25oC) 2(125oC0) 3(-55oC)
B) Dynamic Test or Switching Test
1) Subgroup 4 or 9 (25oC)
C)Functional Test
1) Subgroup 7(25oC) 8a(+125oC) 8b(-55oC)
External Visual
Radiation latch-up
Group B
Group C
Group D
Method
Req.t
Incoming and Outgoing
100%
Inspection Procedures
2010 Cond B (applicable to packaging parts) 100%
Optional
1010, test condition C
100%
2001, test condition E (min)
100%
Y1 orientation only
1014
100%
Note
1
1015, 160 hours at 125
°
C minimum
5 percent
QCI group A
Group A all subgroups
Default procedure
Parameters In accordance with applicable
device specification.
100%
Optional
100%
All lots
Optional
100%
2
3
3
2009
1020
5005
5005
5005
100%
Optional
QCI
QCI
QCI
Notes:
1/ For Pre-assembled product
2/ Manufactured batches shall have Lots tests carried out in accordance with Mil-Std-883
3/ Part No.
LT1012AMH/883
Data sheet included on .PDF copy
Manufacturing
Test
Wire Bond
Die Shear
Marking
Method
2011
2019
2015
Additional manufacturing notes.
Manufactured and processed in accordance with Mil-Std-883 M5005
“Plastic encapsulated Force Technologies Semiconductor devices are not designed and are not warranted suitable for some military
environments/Use of FT encapsulated plastic semiconductor devices in military applications and/or military environments in place of
hermetically sealed ceramic devices, is understood to be fully at the risk of the buyer” Force Technologies Ltd